Luminous Flux Converter
Convert luminous flux between units in real time. Enter a value, choose the from and to units, and read the result instantly.
What luminous flux measures
Luminous flux is the total light output of a source as the human eye would see it, measured in lumens (lm). One lumen is one candela emitted into one steradian, so flux adds up the light leaving a lamp in every direction a fixture allows. A 1000 lm lamp puts out one kilolumen (1 klm).
The unit is photometric, not radiometric: it weights optical power by the eye’s sensitivity curve, which peaks at 555 nm and falls to zero in the ultraviolet and infrared. Two lamps with identical wattage can differ by a factor of ten in lumens.
The conversion rule
Both prefixes are powers of ten, so the conversion is a decimal shift in either direction. Nothing is rounded: kilo means exactly 10³ and milli exactly 10⁻³. The factors in the converter are the SI prefix definitions, not measured constants.
The only practical wrinkle is the display. A value of 0.4 mlm is 0.0004 lm and shows as 0.0004; a value of 4 mlm is 0.004 lm. Keep three or four significant figures in mind when you read a result that sits near the rounding boundary.
Worked example: 1000 lm in klm
The defaults put 1000 in the lm box and ask for klm. Divide by 1000: 1 klm. The same 1000 lm is 1,000,000 mlm, which is why datasheets never quote small lamps in millilumens.
Now suppose a fixture datasheet lists 3,400 lm and your lighting schedule is written in klm. 3,400 ÷ 1000 = 3.4 klm. Four of those fixtures give 13.6 klm, the figure the electrical engineer will use for the circuit’s lighting load calculation.
Conversion table
| lm | klm | mlm |
|---|---|---|
| 450 | 0.45 | 450,000 |
| 800 | 0.8 | 800,000 |
| 1,000 | 1 | 1,000,000 |
| 1,600 | 1.6 | 1,600,000 |
| 3,400 | 3.4 | 3,400,000 |
The 450, 800, 1,100 and 1,600 lm rows correspond to the old 40, 60, 75 and 100 W incandescent equivalence bands. Those numbers survive on packaging because shoppers still buy by wattage, even though the lamp in the box draws 4 to 9 W.
Where luminous flux conversions matter
Flux figures cross three boundaries constantly: lamp datasheets in lm, lighting design software in klm, and legacy catalogues in thousands of lumens written out longhand.
- Fixture schedules and luminaire schedules, where totals are summed in klm.
- Retrofit comparisons, where the old wattage is mapped to a lumen band rather than a wattage.
- Grow-light and horticultural specs, where flux is often quoted in µmol/s and then converted to lumens for a rough human-visible comparison.
- Street lighting tenders, which mix lm per luminaire with klm per kilometre of road.
Flux is not illuminance
Lumens describe the source; lux describes the surface. A 1000 lm lamp spread over 10 m² gives 100 lux, while the same lamp focused onto 1 m² gives 1,000 lux. Office lighting targets 300–500 lux, so a 1000 lm fixture covers roughly 2–3 m² at working-plane height, not a whole room.
Efficacy: how many lumens per watt
Divide flux by input power to compare technologies. An incandescent lamp manages 12–17 lm/W, a halogen 20–25, a compact fluorescent 55–70, and a modern LED 100–160. The theoretical ceiling at 555 nm is 683 lm/W, so a 1000 lm LED needs about 7–10 W while a 1000 lm incandescent needs 60–80 W.
Precision and common mistakes
- Adding lumens of different colour temperatures as if they were interchangeable; a 4000 K and a 2700 K source at 800 lm look different but sum arithmetically.
- Reading klm as thousands of candela, which are different quantities.
- Forgetting that fixture optics lose 10–30 percent of lamp flux before it leaves the housing.
- Comparing a bare lamp figure with a delivered fixture figure without accounting for that loss.
The arithmetic itself is exact, so a mismatch of 1,000 in a total almost always means one row of the schedule was entered in lm while the rest were in klm. Sum in one unit, then convert once at the end.
Building a room-level flux budget
Start from the target illuminance, multiply by the floor area, then divide by two loss factors: luminaire efficiency and the maintenance factor that accounts for dirt on the diffuser. A 30 m² office at 400 lux needs 12,000 lm at the working plane. At 85 percent luminaire efficiency and a 0.8 maintenance factor, that becomes 12,000 ÷ 0.68 ≈ 17,600 lm, or 17.6 klm of installed lamp flux.
Divide by the output of one fixture to get a count. A 3,200 lm panel would need 5.5 units, rounded to six, which delivers 19.2 klm and lands the room slightly above target. That rounding step is why a schedule rarely matches the arithmetic exactly, and why the klm total on the drawing is usually a little higher than the lumen requirement.
A quick check
One klm is a thousand lumens, and one lumen per square foot is 10.76 lux. If a room needs 400 lux over 20 m², that is 8,000 lux-metres, or 8 klm of delivered flux before any loss factor. Add 20 percent for luminaire efficiency and you are specifying about 10 klm.
Frequently asked questions
How many lumens is 1 klm?
Exactly 1,000 lumens. Kilo is 10³, so 2.5 klm is 2,500 lm and 0.4 klm is 400 lm.
How many lumens does a 60 W bulb give?
About 800 lm for an incandescent, which is 0.8 klm. The LED replacement that matches it typically draws 8–10 W at 100 lm/W.
How many mlm are in 1.5 lm?
1,500 mlm. One millilumen is one thousandth of a lumen, so multiply by 1,000: 1.5 × 1000 = 1,500.
What is 3,400 lm in klm?
3.4 klm. That is a common four-lamp linear fixture output, and six of them total 20.4 klm.
Is a lumen the same as a lux?
No. A lumen is total output; a lux is one lumen per square metre of surface. 1,000 lm landing on 10 m² produces 100 lux.
Why do LED boxes still show wattage equivalence?
Because buyers compare against the lamp they are replacing. The 800 lm label maps to a 60 W incandescent, 1,600 lm to 100 W, and the actual LED draw is roughly one sixth to one tenth of those figures.
How do I convert lumens to candela?
Divide by the solid angle in steradians. A 1,000 lm lamp radiating into a full sphere of 4π sr averages 79.6 cd; the same lamp behind a 20° reflector reaches several thousand candela on axis.
Is the conversion affected by colour temperature?
Not the arithmetic. Lumens already include the eye’s weighting, so a warm and a cool lamp at 800 lm both convert to 0.8 klm. What changes is the subjective brightness and the colour rendering.
How much flux does a room need?
Multiply target lux by floor area, then divide by fixture efficiency. At 300 lux over 15 m² you need 4,500 lm delivered, or about 5.6 klm of installed lamp flux at 80 percent efficiency.
Why does the same lamp quote different lumen figures in two catalogues?
Lamp flux and luminaire flux are different measurements. A bare tube rated 3,200 lm may deliver 2,700 lm from the fixture after optical and thermal losses, a gap of about 16 percent. Compare like with like before converting to klm.
Method and sources
- Linear conversion through lm: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 Kilolumen (klm) = 1000 lm; 1 Millilumen (mlm) = 0.001 lm.
- Every factor is an exact decimal SI prefix of the base unit, so no rounded constant is involved.
- Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.