CalcSeed

Specific Heat Capacity Converter

Convert specific heat capacity between units in real time. Enter a value, choose the from and to units, and read the result instantly.

=
Specific Heat Capacity Converter — convert between J/(kg·K), kJ/(kg·K), J/(g·°C) and more.
Result
—

What this converter returns

Specific heat capacity is the energy needed to raise one unit of mass by one degree, so it carries an energy unit, a mass unit and a temperature unit at once. This tool converts it across five combinations: J/(kg·K), kJ/(kg·K), J/(g·°C), cal/(g·°C) and BTU/(lb·°F). The default is 1,000 J/(kg·K) into cal/(g·°C), which returns 0.2390.

result = value × factorfrom ÷ factorto
1 kJ/(kg·K) = 1,000 J/(kg·K) · 1 J/(g·°C) = 1,000 J/(kg·K) · 1 cal/(g·°C) = 4,184 J/(kg·K) · 1 BTU/(lb·°F) = 4,186.8 J/(kg·K)

How each factor is built

The SI unit, J/(kg·K), is the pivot with a factor of 1. The kilojoule and the gram are exact decimal steps, so kJ/(kg·K) and J/(g·°C) both land on exactly 1,000. Those two are the same unit written differently: one joule per gram is 1 J ÷ 0.001 kg = 1,000 J per kilogram, and a temperature interval of 1 °C is exactly 1 K because the Celsius scale is offset, not rescaled.

The calorie entry depends on which calorie you mean. This tool uses the thermochemical calorie of exactly 4.184 J, so 1 cal/(g·°C) is 4.184 ÷ 0.001 = 4,184 J/(kg·K). Nutrition labels and steam tables sometimes use the International Table calorie of 4.1868 J, which would give 4,186.8. The 0.067% gap is invisible in a kitchen and significant in a boiler calculation.

The BTU factor is a compound of three definitions. One International Table BTU is 1,055.05585262 J, one pound is 0.45359237 kg, and one Fahrenheit degree is 5/9 K. Dividing gives 1,055.0559 ÷ (0.45359237 × 0.5556) = 4,186.8 J/(kg·K). That is why 1 BTU/(lb·°F) sits so close to 1 cal/(g·°C): both are roughly the energy to heat a pound or a gram of water by one degree.

Worked example at the default settings

Take 1,000 J/(kg·K) into cal/(g·°C). The arithmetic is 1,000 × 1 ÷ 4,184 = 0.239006, shown as 0.2390. Into BTU/(lb·°F) it is 1,000 ÷ 4,186.8 = 0.238846. The two differ by 0.067%, which is exactly the ratio of the two calorie conventions.

The same value in the metric units: 1,000 J/(kg·K) is 1 kJ/(kg·K) and 1 J/(g·°C). Being able to swap between those two without moving the digits is the reason process engineers write kJ/(kg·K) and materials scientists write J/(g·°C) for the same number.

Specific heat of common materials

MaterialJ/(kg·K)cal/(g·°C)BTU/(lb·°F)
Water (25 °C)4,1821.0000.9988
Ice (0 °C)2,0900.5000.4992
Ethanol2,4400.5830.5826
Air (constant pressure)1,0050.2400.2400
Aluminium9000.2150.2150
Steel (mild)4900.1170.1170
Copper3850.09200.0920

Water’s value is the reason the calorie and the BTU exist: one calorie heats one gram of water by one degree, one BTU heats one pound by one Fahrenheit degree, and the two definitions nearly coincide because 453.6 g × 0.5556 °C × 4.184 J = 1,054 J, within 0.1% of one BTU.

Where specific heat decides an outcome

  • Sensible heat: Q = m · c · ΔT, so heating 2 kg of water by 60 K needs 2 × 4,182 × 60 = 501.8 kJ.
  • HVAC and chillers: water carries 4.18 kJ per kg per K, so a 10 K rise at 1 kg/s moves 41.8 kW.
  • Thermal storage: a 300 L tank storing a 40 K swing holds 300 × 4.182 × 40 = 50.2 MJ, about 13.9 kWh.
  • Materials selection: copper at 385 J/(kg·K) heats about 10.9 times faster than water for the same energy per kilogram.
  • Cooking: oil at roughly 2,000 J/(kg·K) heats faster than water at 4,182, which is why oil reaches 180 °C before a pan of water boils dry.

The chiller row is the everyday one. A 41.8 kW load at a 10 K water rise needs about 1 kg/s, which is 60 L/min, or roughly 15.9 gpm. Size the pipe from a 5 K rise instead and the flow doubles to 120 L/min, changing the pump and the pipe schedule with it, which is why the design temperature difference is fixed before the pipe drawing is issued.

J/(g·°C) and kJ/(kg·K) are the same number

This trips up almost everyone the first time. One gram is 0.001 kg, so dividing by grams multiplies the number by 1,000; kilojoules divide by 1,000, cancelling it exactly. A polymer datasheet quoting 1.7 J/(g·°C) is stating 1.7 kJ/(kg·K), and both equal 1,700 J/(kg·K). No conversion is needed, and a tool that returns a different number for that pair is wrong.

Mistakes that shift the result

  • Mixing the calorie conventions: 4.184 against 4.1868 shifts a result by 0.067%, enough to matter in steam-cycle work.
  • Forgetting that °C and K intervals are equal: only absolute temperatures differ by 273.15, not temperature differences.
  • Treating J/(kg·°C) as a different unit from J/(kg·K): for specific heat they are identical.
  • Using the specific heat of ice for water: 2,090 against 4,182 J/(kg·K) is a factor of two, not a rounding difference.

The ice-versus-water error has a visible consequence. Melting 1 kg of ice takes 334 kJ of latent heat before any warming begins, and then heating the meltwater by 1 K takes only 4.18 kJ. A calculation that uses one value for the whole range from −10 °C to +10 °C misses the phase change entirely and predicts a warm-up about 40 times too fast.

Precision and significant figures

Specific heat is a measured property, not a defined constant, so the value is usually good to three or four digits and drifts with temperature. Water runs 4,218 J/(kg·K) at 0 °C, 4,182 at 25 °C and 4,216 near 100 °C. Quoting a result to six digits implies precision the input does not have; two or three is honest for engineering work.

A kettle check

A 1.7 L kettle holds 1.7 kg of water, and heating it from 15 °C to 100 °C needs 1.7 × 4,182 × 85 = 604 kJ. At 2,000 W and 85% efficiency that is 604,000 ÷ 1,700 = 355 s, close to six minutes, which is why a full kettle takes noticeably longer than a half-full one and why the element rating matters more than the jug size.

Frequently asked questions

How do I convert J/(kg·K) to cal/(g·°C)?

Divide by 4,184. For example, 1,000 J/(kg·K) ÷ 4,184 = 0.2390 cal/(g·°C).

Is 1 J/(g·°C) the same as 1 kJ/(kg·K)?

Yes, exactly. One joule per gram is 1,000 J per kilogram, and a kilojoule is 1,000 joules, so the two units return identical numbers.

How many BTU/(lb·°F) is 1 cal/(g·°C)?

0.9993, because 4,184 ÷ 4,186.8 = 0.99933. The 0.067% gap comes from the thermochemical calorie against the International Table BTU.

What is the specific heat of water?

About 4,182 J/(kg·K) at 25 °C, which is 1.000 cal/(g·°C) and 0.9988 BTU/(lb·°F). It rises to 4,218 J/(kg·K) near freezing.

How do I convert BTU/(lb·°F) to J/(kg·K)?

Multiply by 4,186.8. A value of 0.240 BTU/(lb·°F) is 1,005 J/(kg·K), the specific heat of air at constant pressure.

Why does temperature in °C and K convert as a 1:1 ratio?

The scales differ by an offset of 273.15, not a multiplier, so a difference of 1 °C equals a difference of 1 K. Only absolute temperatures need the offset.

How much energy heats 1 kg of water by 1 °C?

4.182 kJ, since Q = 1 × 4,182 × 1. That is also 1 kcal and roughly 3.97 BTU.

What is the specific heat of aluminium?

900 J/(kg·K), or 0.215 cal/(g·°C). It is about 4.6 times lower than water, which is why an aluminium pan heats quickly.

Does specific heat change with temperature?

Yes. Water moves from 4,218 J/(kg·K) at 0 °C to 4,182 at 25 °C, and metals rise slowly with temperature. Use a value at the working temperature for accurate work.

Method and sources

Calculation basis

Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: November 19, 2026
Formula & data sources
  • Linear conversion through J/(kg·K): result = value × factor(from) ÷ factor(to).
  • Factors applied: 1 kJ/(kg·K) = 1000 J/(kg·K); 1 J/(g·°C) = 1000 J/(kg·K); 1 cal/(g·°C) = 4184 J/(kg·K); 1 BTU/(lb·°F) = 4186.8 J/(kg·K).
  • The kilojoule and gram factors are exact powers of ten, and a 1 °C interval equals 1 K. Two calorie conventions appear: cal/(g·°C) uses the thermochemical calorie (4.184 J) while BTU/(lb·°F) = 4186.8 J/(kg·K) uses the International Table calorie (4.1868 J). They differ by 0.067%.
  • Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.

Cite this page

Reference formats
APA 7CalcSeed. (2026, November 19). Specific Heat Capacity Converter. https://calcseed.com/c/unit/specific-heat-capacity-converter/
MLA 9"Specific Heat Capacity Converter." CalcSeed, 19 Nov. 2026, calcseed.com/c/unit/specific-heat-capacity-converter/.
ChicagoCalcSeed. "Specific Heat Capacity Converter." Last modified November 19, 2026. https://calcseed.com/c/unit/specific-heat-capacity-converter/

Related calculators