CalcSeed

Heat Flux Converter

Convert heat flux between units in real time. Enter a value, choose the from and to units, and read the result instantly.

=
Heat Flux Converter — convert between W/m², BTU/(h·ft²), W/cm² and more.
Result
—

What heat flux measures

Heat flux is the rate at which heat crosses a unit area, in watts per square metre. It is not the total heat and not the temperature: it is power density, and it is what determines whether a surface stays cool or melts. This converter handles W/m², BTU per hour per square foot, W/cm² and kcal per hour per square metre. At the defaults it turns 100 W/m² into 31.7 BTU/(h·ft²).

The conversion formula

result = value × factorfrom ÷ factorto  ·  q = Q ÷ A  ·  1 BTU/(h·ft²) = 3.15459 W/m²  ·  1 W/cm² = 10,000 W/m²  ·  1 kcal/(h·m²) = 1.163 W/m²

The watt per square metre is the coherent unit. The watt per square centimetre is an exact ten thousand, because a square centimetre is 10-4 m². The kilocalorie per hour per square metre is 1.163 W/m², since one International Table calorie is 4.1868 J and an hour is 3,600 seconds: 4,186.8 ÷ 3,600 = 1.163 exactly.

The BTU per hour per square foot is the awkward one: 1,055.05585262 J ÷ 3,600 s ÷ 0.09290304 m² = 3.15459 W/m². That factor is rounded because the BTU is a defined non-SI unit, but the rounding sits at the seventh digit, far below any measurement uncertainty.

Worked example: 100 W/m²

At the defaults the value is 100 and the units run from W/m² to BTU/(h·ft²): 100 ÷ 3.15459 = 31.7 BTU/(h·ft²). That is a modest flux, roughly what a person gives off per square metre of skin at rest, and it is the sort of number that appears in building-envelope calculations.

The same 100 W/m² is 0.01 W/cm² and 86.0 kcal/(h·m²). The three answers look unrelated until you notice that each unit was chosen for a different industry: W/m² for physics, W/cm² for electronics cooling, kcal/(h·m²) for European heating practice.

Heat flux conversions at a glance

FromTo unitMultiply by
1 W/m²BTU/(h·ft²)0.31700
1 W/m²W/cm²0.0001
1 W/m²kcal/(h·m²)0.85985
1 BTU/(h·ft²)W/m²3.15459
1 W/cm²W/m²10,000
1 W/cm²BTU/(h·ft²)3,171
1 kcal/(h·m²)W/m²1.163

The 0.317 row is the one to memorise, because it turns a solar or HVAC number into US units in a single step. One sun of irradiance, 1,000 W/m², is 317 BTU/(h·ft²), and the solar constant of 1,361 W/m² is 431 BTU/(h·ft²).

Heat fluxes in real systems

SystemW/m²W/cm²
Human body at rest550.0055
Solar constant at Earth orbit1,3610.136
Clear-sky noon on the ground1,0000.10
Domestic radiator surface500–1,0000.05–0.10
Electric stove burner150,00015
Rocket nozzle throat107–1081,000–10,000

The gap between a radiator and a rocket throat is five orders of magnitude, and it is bridged by the same equation: flux equals temperature difference divided by thermal resistance. A stove burner at 15 W/cm² is why a pan must conduct heat away quickly, and a rocket throat at 10,000 W/cm² is why nozzles are regeneratively cooled rather than simply made thicker.

Where the conversion bites in practice

  • Solar and HVAC data are split between W/m² and BTU/(h·ft²). A window film rated at 200 BTU/(h·ft²) rejects 631 W/m², roughly two-thirds of peak sun.
  • Electronics cooling is quoted in W/cm² because a die is small: a 100 W processor on 4 cm² runs at 25 W/cm² and needs a vapour chamber, while 1 W/cm² is fan-cooled territory.
  • Fire engineering uses kW/m² for incident flux, so a 50 kW/m² exposure is 5 W/cm² and is enough to ignite wood within minutes.
  • Building codes quote U-values in W/(m²·K), not W/m². The flux through a wall is U times the temperature difference, so a U of 0.3 and a 20 K difference give 6 W/m².

The last row is the mistake that matters most. Heat flux in W/m² is a rate at a moment; U-value in W/(m²·K) is a property of an assembly. Multiplying the two together with a temperature difference is the only correct way to get from one to the other, and the units are the reminder.

Common mistakes

Flux is not total heat

A 100 W/m² flux over 10 m² is 1,000 W, and the same flux over 0.1 m² is 10 W. Neither number is more correct; they answer different questions. Sizing a heater needs total power, sizing a surface needs flux, and mixing them produces a design that is wrong by the area ratio.

Square feet hide a factor of 10.76

A BTU per hour is small and a square foot is small, so the per-area imperial unit is 3.15 times the SI one, not 10.76 times. Converting area and power separately and then dividing is safe; converting the per-area unit by the area factor alone is not. Check with the solar constant, which is 1,361 W/m² and 431 BTU/(h·ft²).

Time bases cause the other slips. A BTU per hour per square foot is a rate, so a value in BTU/ft² without the per-hour is an energy per area, not a flux. That distinction is invisible in casual writing and decisive in a calculation.

  • Divide W/m² by 3.15 to get BTU/(h·ft²): 1,000 W/m² is 317 and the solar constant of 1,361 is 431.
  • 1 W/cm² is 10,000 W/m² and 3,171 BTU/(h·ft²), so a 15 W/cm² burner is 150,000 W/m².
  • A U-value is not a flux: multiply by the temperature difference, so U 0.3 at 20 K gives 6 W/m².

Precision and rounding

The W/cm² and kcal factors are exact; the BTU factor is stored rounded to seven figures. Real measurements dominate anyway: a heat-flux sensor is typically good to 3 to 5 percent, and convective coefficients in air vary by more than that between correlations. Two significant figures is often honest for a calculated flux.

Very large fluxes need scientific notation, and the converter handles that. A rocket throat at 108 W/m² is 10,000 W/cm² and 31.7 million BTU/(h·ft²), so choose the unit that keeps the number readable and state it explicitly in any report.

Frequently asked questions

How many W/m2 is 1 BTU per hour per square foot?

3.15459 W/m². The International Table BTU is 1,055.056 J, an hour is 3,600 s and a square foot is 0.09290304 m², which combine to that factor. A 1,000 W/m² sun is 317 BTU/(h·ft²).

How do I convert 100 W/m2 to BTU?

Divide by 3.15459: 100 W/m² is 31.7 BTU/(h·ft²). That is roughly the flux from a resting human body, about 55 W/m² being a closer figure at basal metabolic rate.

How many W/m2 is 1 W/cm2?

10,000 W/m². A square centimetre is 10-4 m², so the flux in W/cm² is the W/m² figure divided by 10,000. A 15 W/cm² stove burner is 150,000 W/m².

Is heat flux the same as a U-value?

No. Heat flux in W/m² is the actual rate through a surface; a U-value in W/(m²·K) is a property of the assembly. Multiply U by the temperature difference to get flux, so a U of 0.3 and 20 K gives 6 W/m².

What is the solar constant in BTU?

431 BTU/(h·ft²), from 1,361 W/m² divided by 3.15459. At ground level with a clear sky, about 1,000 W/m² arrives, which is 317 BTU/(h·ft²).

How do I convert kcal per hour per square metre?

Multiply by 1.163. One kilocalorie per hour is 1.163 W, so a radiator rated at 860 kcal/(h·m²) delivers 1,000 W/m².

Why do electronics use W/cm2?

Because dies are small and the numbers stay readable. A 100 W chip on 4 cm² is 25 W/cm², a flux that needs a vapour chamber, while 1 W/cm² can be handled by a fan and heatsink.

How much heat flux ignites wood?

About 10 to 20 kW/m² sustained, which is 1 to 2 W/cm². Piloted ignition comes faster at 30 to 50 kW/m², and fire codes often test at 50 kW/m².

Does heat flux depend on temperature?

Yes, through the driving temperature difference and the heat-transfer coefficient. Radiative flux scales with the fourth power of absolute temperature, so doubling surface temperature multiplies it by sixteen.

Method and sources

Calculation basis

Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: November 19, 2026
Formula & data sources
  • Linear conversion through W/m²: result = value × factor(from) ÷ factor(to).
  • Factors applied: 1 BTU/(h·ft²) = 3.15459 W/m²; 1 W/cm² = 10000 W/m²; 1 kcal/(h·m²) = 1.163 W/m².
  • Watts per square centimetre is an exact power of ten, and 1 kcal/(h·m²) = 1.163 W/m² exactly from the International Table calorie (4.1868 J). The BTU per hour-square foot uses the International Table BTU and the international foot and is stored rounded.
  • The SI prefixes are exact; the BTU/(h·ft²) factor is stored as a rounded decimal, the largest deviation being 2.4e−5% relative. A result carries that rounding on top of floating-point arithmetic.