CalcSeed

Magnetic Flux Density Converter

Convert magnetic flux density between units in real time. Enter a value, choose the from and to units, and read the result instantly.

=
Magnetic Flux Density Converter — convert between Tesla (T), Millitesla (mT), Gauss (G) and more.
Result
—

What this converter returns

Magnetic flux density is how much magnetic flux passes through a unit area, and it sets the force on a current, the voltage in a transformer and the pull of a magnet. This tool converts across four units: tesla, millitesla, gauss and kilogauss. The default is 1 T into gauss, which returns 10,000 G.

result = value × factorfrom ÷ factorto
1 T = 1 Wb/m² = 1 kg/(A·s²) · 1 mT = 0.001 T · 1 G = 10−4 T · 1 kG = 0.1 T

Why the gauss is a ten-thousandth of a tesla

The tesla is the SI unit and equals one weber per square metre, which in base units is one kilogram per ampere-second squared. The gauss is the CGS unit and was defined as one maxwell per square centimetre. A maxwell is 10−8 weber and a square centimetre is 10−4 m², so 1 G is 10−8 ÷ 10−4 = 10−4 T. The awkward ten thousand is the price of mixing centimetre-gram-second units with metre-kilogram-second ones.

The two prefixes are ordinary. One millitesla is 0.001 T, and since 1 T is 10,000 G, 1 mT is 10 G exactly. One kilogauss is 1,000 G, which is 0.1 T. Those two relationships cover most engineering work, because motor and transformer designers think in tesla while older magnetics literature and astronomy think in gauss.

Worked example at the default settings

Take 1 T into gauss. The arithmetic is 1 × 1 ÷ 0.0001 = 10,000 G. The same field is 1,000 mT and 10 kG, so a magnet quoted at 1 T, 1,000 mT or 10 kG is the same magnet described three ways.

Try an MRI scanner at 1.5 T. That is 1,500 mT, 15,000 G and 15 kG. The 5-gauss safety line that every MRI suite marks on the floor is 0.0005 T, or 0.5 mT, which is why the line sits several metres from the bore rather than at the door.

Fields you can compare against

Sourceteslagauss
Earth surface field0.000050.5
Fridge magnet0.00550
Neodymium N52, at pole face1.414,000
Transformer core, saturated1.818,000
MRI scanner, 1.5 T1.515,000
Superconducting lab magnet20200,000
Strongest pulsed field1,20012,000,000

The table spans more than seven orders of magnitude, which is why prefixes matter. Earth field at 0.5 G and a pulsed magnet at 12 million gauss are both quotable in gauss, but nobody writes the second as 1,200 T without pausing, and nobody writes the first in tesla without four leading zeros.

Where the unit choice changes an outcome

  • MRI safety: the 5-gauss line is 0.5 mT, and any implant rated below 1.5 T must be checked against the actual field map, not the nominal bore field.
  • Motor design: steel saturates near 1.8 T (18,000 G), so a design asking for 2.2 T in the teeth is asking for a field the iron cannot carry.
  • Hall sensors: sensitivity is quoted in mV per gauss or mV per tesla, and a 1.5 mV/G part is 15 mV/mT, a factor of 10 that changes the amplifier gain.
  • Magnetic separation: tramp-iron magnets are specified at 1,200–2,000 G on the belt surface, which is 0.12–0.2 T, far below a neodymium pole face.
  • Astronomy and geophysics: planetary fields are quoted in gauss, and Jupiter at 4.3 G is 0.43 mT, about eight times Earth.

The MRI row is the one with legal consequences. The 5-gauss contour is where pacemakers and ferromagnetic implants start being at risk, and it is drawn from a field map rather than assumed. A 3 T scanner pushes that contour much further into the room than a 1.5 T unit, which is why suites are designed around the magnet rather than the other way round.

Flux density, flux and field strength are different things

Flux density B is measured in tesla and is what this converter handles. Magnetic flux Φ is B times area and is measured in webers, so a 1 T field through 0.01 m² is 0.01 Wb. Magnetic field strength H is a different quantity in A/m and does not include the material. Mixing B and H is the most common error in magnetics, and no unit conversion can rescue it.

Mistakes that shift the number

  • Using 1,000 instead of 10,000 between tesla and gauss, which understates a 1.5 T field as 1,500 G instead of 15,000 G.
  • Confusing mT with G: 1 mT is 10 G, so a 50 mT magnet is 500 G, not 50 G.
  • Treating gauss and oersted as interchangeable: they are numerically equal only in a vacuum, and they measure different quantities.
  • Reading a pole-face figure as a working gap figure: a 1.4 T neodymium pole face may give 0.4 T across a 5 mm gap.

The gap point matters in any magnet design. Flux density falls quickly with distance from a pole face, roughly halving over a gap comparable to the pole width, so a datasheet 1.4 T becomes 0.3–0.5 T at a useful working distance. Sizing a holding force from the pole-face figure overstates the pull by a factor of four or more.

Precision and rounding

All four factors are exact powers of ten, so the conversion adds no error. Measurement is the limit: a Hall probe is good to 1–2% and a NMR teslameter to 0.001%, which is why high-field calibration uses NMR and everyday work uses a Hall sensor. Quoting 15,000.0 G from a Hall probe overstates the certainty by three digits.

Gradients are quoted in tesla per metre, because a uniform field exerts no net force on a dipole and no signal on many sensors. An MRI gradient of 40 mT/m over 0.5 m is a 20 mT difference, or 200 G across the body, and that gradient rather than the static field is what drives peripheral nerve stimulation at high slew rates.

A transformer check

Transformer core loss rises steeply with flux density, roughly as B to the power 1.6 to 2.0, so running a core at 1.8 T instead of 1.5 T can double the loss. In gauss that is 18,000 against 15,000, a 20% rise in B and a 35–45% rise in loss, which is why designs sit near 1.5–1.7 T even when the steel is rated to 1.9 T.

Frequently asked questions

How do I convert tesla to gauss?

Multiply by 10,000. A 1.5 T MRI field is 15,000 G, and the Earth field of 0.00005 T is 0.5 G.

How many gauss are in 1 millitesla?

Exactly 10, because 1 mT is 0.001 T and 0.001 × 10,000 = 10. A 50 mT magnet is 500 G.

How many tesla is 1 kilogauss?

0.1 T. A kilogauss is 1,000 G, and 1,000 × 0.0001 = 0.1 T.

Why is the gauss factor 10<sup>&minus;4</sup>?

The gauss is one maxwell per square centimetre. A maxwell is 10−8 Wb and a square centimetre is 10−4 m², so the ratio is 10−4 T.

What is the 5-gauss line at an MRI?

The contour where the field falls to 5 G, or 0.5 mT. That is the boundary where pacemakers and ferromagnetic implants become a hazard, and it sits several metres from a 1.5 T scanner.

How strong is a fridge magnet in tesla?

About 0.005 T on contact, which is 5 mT or 50 G. A neodymium N52 magnet at its pole face is 1.4 T, or 14,000 G, 280 times stronger.

What is the difference between flux density and flux?

Flux density B is in tesla and measures flux per area; flux Φ is in webers and is B times area. A 1 T field through 0.01 m² is 0.01 Wb.

How strong is the Earth magnetic field?

Between 0.000025 and 0.000065 T depending on latitude, which is 0.25–0.65 G or 25–65 µT.

Can a magnet exceed 2 tesla?

Only with superconducting or pulsed coils. Iron cores saturate near 1.8 T, while lab superconductors reach 20 T (200,000 G) and pulsed systems have reached 1,200 T.

Method and sources

Calculation basis

Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: November 19, 2026
Formula & data sources
  • Linear conversion through T: result = value × factor(from) ÷ factor(to).
  • Factors applied: 1 Millitesla (mT) = 0.001 T; 1 Gauss (G) = 0.0001 T; 1 Kilogauss (kG) = 0.1 T.
  • The millitesla is an exact SI prefix; the gauss and kilogauss are exact CGS definitions (1 G = 10⁻⁴ T).
  • Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.

Cite this page

Reference formats
APA 7CalcSeed. (2026, November 19). Magnetic Flux Density Converter. https://calcseed.com/c/unit/magnetic-flux-density-converter/
MLA 9"Magnetic Flux Density Converter." CalcSeed, 19 Nov. 2026, calcseed.com/c/unit/magnetic-flux-density-converter/.
ChicagoCalcSeed. "Magnetic Flux Density Converter." Last modified November 19, 2026. https://calcseed.com/c/unit/magnetic-flux-density-converter/

Related calculators