Mass Flux Converter
Convert mass flux between units in real time. Enter a value, choose the from and to units, and read the result instantly.
What mass flux density measures
Mass flux density is mass crossing one square metre of area per second: kilograms per square metre per second, kg/(m²·s). Drying engineers, heat-pipe designers and atmospheric scientists all use it, but each community prefers a different unit. At the defaults, 1 kg/(m²·s) converts to 3,600 kg/(m²·h).
The conversion is one ratio against a common base: result = value × factor(from) ÷ factor(to), where kg/(m²·s) has factor 1 and every other unit is expressed as the number of kg/(m²·s) it represents.
Why the time factor is 3,600 and the imperial one is 4.88
The per-hour unit is pure arithmetic. One hour contains 3,600 seconds, so a rate per hour is 3,600 times smaller than the same rate per second: 1 kg/(m²·s) = 3,600 kg/(m²·h) = 3.6 t/(m²·h). Going the other way divides by 3,600, which is where the stored factor 0.000277778 comes from (1÷3600 = 0.00027777…).
The pound per square foot per second is not a clean multiple. It combines two unrelated definitions: the avoirdupois pound at exactly 0.45359237 kg, and the square foot at 0.09290304 m². Dividing them gives 0.45359237 ÷ 0.09290304 = 4.882427636 kg/(m²·s), so one imperial unit is nearly five times the metric one. That ratio is why a number that looks modest in lb/(ft²·s) looks large in kg/(m²·s).
The gram unit is a three-decimal shift
A gram is 0.001 kg, so 1 g/(m²·s) = 0.001 kg/(m²·s) and 1,000 g/(m²·s) = 1 kg/(m²·s). Because the area and the time do not change, this is only a prefix move: 250 g/(m²·s) is 0.25 kg/(m²·s), or 900 kg/(m²·h).
Worked example at the default settings
Start with 1 kg/(m²·s). Multiply by the from-factor of 1, then divide by the to-factor 0.000277777778: 1 ÷ 0.000277777778 = 3,600 kg/(m²·h). The tiny shortfall from a perfect 3,600 comes from storing 1÷3600 as a rounded decimal and is about 9e-10 in relative terms, far below any measurement tolerance.
The same flux in the other two units: 1 × 1 ÷ 0.001 = 1,000 g/(m²·s), and 1 ÷ 4.882427636 = 0.2048 lb/(ft²·s). Multiply that last figure by 3,600 and you get 737.3 lb/(ft²·h), a unit some American drying specs still print.
The same flux in four common units
| Input | kg/(m²·s) | kg/(m²·h) | lb/(ft²·s) |
|---|---|---|---|
| 1 kg/(m²·s) | 1 | 3,600 | 0.2048 |
| 1 g/(m²·s) | 0.001 | 3.6 | 0.0002048 |
| 1 kg/(m²·h) | 0.0002778 | 1 | 0.0000569 |
| 1 lb/(ft²·s) | 4.8824 | 17,576.7 | 1 |
| 1 lb/(ft²·h) | 0.0013562 | 4.8824 | 0.0002778 |
Two rows are worth memorising because they come up constantly. One kg/(m²·h) is a millimetre of water per hour, which makes rainfall and irrigation conversions trivial. One lb/(ft²·s) is just under 5 kg/(m²·s), so an American figure of 0.1 lb/(ft²·s) is about 0.49 kg/(m²·s).
Where the conversion bites in practice
- Evaporation and drying: a flux of 1 kg/(m²·h) removes 0.68 kW/m² of latent heat at 2,450 kJ/kg, so a 10 kg/(m²·h) dryer needs 6.8 kW/m² of heat input.
- Rainfall: 1 mm of rain in an hour is 1 kg/(m²·h), because a millimetre of water over a square metre weighs a kilogram. A 10 mm/h downpour is 0.00278 kg/(m²·s).
- Plant transpiration: a crop using 5 mm/day averages 0.208 kg/(m²·h), or 5.8e-5 kg/(m²·s) — four orders of magnitude below industrial drying.
- Combustion air and propellant flow: boiler tubes run at 1,000–3,000 kg/(m²·s), while rocket injectors reach 5,000 kg/(m²·s) or more.
Mass flux is not mass flow rate
Flux is per unit area; flow rate is the total. A pipe carrying 2 kg/s through a 0.01 m² bore has a flux of 200 kg/(m²·s), and the same 2 kg/s through a 0.5 m² duct is only 4 kg/(m²·s). Confusing the two is the single most common error in this family of units: a value quoted as kg/(m²·s) cannot be turned into kg/s without knowing the cross-section, and a value in kg/s cannot be compared with a flux limit from a data sheet until you divide by area.
Flux, velocity and density are three different things
Mass flux also equals density times velocity, which is the quickest way to sanity-check a number. Air at 1.2 kg/m³ moving at 5 m/s carries 6 kg/(m²·s); a 10 m/s wind carries 12. Water at 1,000 kg/m³ moving at just 2 m/s carries 2,000 kg/(m²·s), three hundred times the air figure at a fifth of the speed. If a calculated flux implies a velocity no pump or fan could deliver, the flux is wrong, not the physics.
Precision and sensible magnitudes
Only the hour factor carries storage rounding, at roughly 1e-9 relative, and the imperial factor is quoted to ten significant figures, so neither limits a practical result. Design work lives between 0.0001 kg/(m²·s) for slow transpiration and 5,000 kg/(m²·s) for high-pressure injectors — seven orders of magnitude, which is why getting the unit right matters more than getting the third decimal right.
When you report a figure, match the precision of the source. A rain gauge reading of 2.4 mm/h does not support a flux quoted to six decimals; 2.4 kg/(m²·h) or 0.00067 kg/(m²·s) both carry the same two significant figures.
Mistakes that shift the answer by 3,600×
- Reading a per-hour value as per-second. The error is exactly 3,600, so a dryer rated 900 kg/(m²·h) is 0.25 kg/(m²·s), not 900.
- Using lb/(ft²·h) when the table heading says lb/(ft²·s), a further 3,600-fold error.
- Forgetting that a tonne per square metre per hour is 1,000 kg/(m²·h), not 1 kg/(m²·h).
- Converting a flux straight to a total mass without multiplying by area and time: 4 kg/(m²·s) over 2 m² for 30 s moves 240 kg.
Frequently asked questions
How many kg/(m²·h) is 1 kg/(m²·s)?
Exactly 3,600, because an hour holds 3,600 seconds. The converter prints 3,600 too; the stored factor 0.000277778 introduces an error of under one part in a billion.
What is 1 lb/(ft²·s) in metric units?
4.8824 kg/(m²·s), which is 17,576.7 kg/(m²·h) or 4,882.4 g/(m²·s). The factor comes from 0.45359237 kg ÷ 0.09290304 m².
How do I convert 10 g/(m²·s) to kg/(m²·h)?
First 10 g/(m²·s) = 0.01 kg/(m²·s), then multiply by 3,600 to get 36 kg/(m²·h).
How many millimetres of rain per hour is 1 kg/(m²·h)?
One millimetre. A square metre of water one millimetre deep weighs 1 kg, so a flux of 1 kg/(m²·h) is exactly 1 mm/h, and a 25 mm/h storm is 25 kg/(m²·h) or 0.00694 kg/(m²·s).
Is mass flux the same as mass flow rate?
No. Mass flow rate is total kilograms per second; mass flux is kilograms per second per square metre. A 2 kg/s flow through 0.01 m² is 200 kg/(m²·s); the same flow through 0.5 m² is 4 kg/(m²·s).
What is a typical mass flux in industrial drying?
Between 1 and 30 kg/(m²·h) for convection dryers, which is 0.00028 to 0.0083 kg/(m²·s). Impingement dryers run higher, often 50–200 kg/(m²·h).
How do I turn a flux into a total mass?
Multiply by area and by time. A flux of 4 kg/(m²·s) across 2 m² for 30 s moves 4 × 2 × 30 = 240 kg.
Why is 1 kg/(m²·s) equal to 3.6 tonnes per square metre per hour?
3,600 kg is 3.6 tonnes, and the area is unchanged, so the hourly rate is 3.6 t/(m²·h).
Does the converter handle lb/(ft²·h)?
Not directly, but the conversion is one step: divide an lb/(ft²·h) figure by 3,600 to get lb/(ft²·s), then enter that. Ten lb/(ft²·h) is 0.00278 lb/(ft²·s) or 0.01356 kg/(m²·s).
Method and sources
- Linear conversion through kg/(m²·s): result = value × factor(from) ÷ factor(to).
- Factors applied: 1 g/(m²·s) = 0.001 kg/(m²·s); 1 kg/(m²·h) = 0.000277777778 kg/(m²·s); 1 lb/(ft²·s) = 4.882427636 kg/(m²·s).
- The gram factor is an exact power of ten. Kilograms per square metre-hour divides by 3600, and pounds per square foot-second follows from the international pound and foot; both are stored rounded.
- Every factor is an exact definition or an exact decimal SI prefix. The stored decimals are rounded only in their last digits — at most 8.0e−8% relative — which is negligible for any measurement.