CalcSeed

Magnetic Permeability Converter

Convert magnetic permeability between units in real time. Enter a value, choose the from and to units, and read the result instantly.

=
Magnetic Permeability Converter — convert between H/m, mH/m, µH/m and more.
Result
—

What this converter returns

Magnetic permeability describes how strongly a material supports magnetic flux: the flux density it produces for a given magnetising field. This page converts between henries per metre, millihenries per metre and microhenries per metre. At the defaults it turns 1.256637 µH/m into 1.256637 × 10−6 H/m, which is the permeability of free space.

The henry per metre is a derived SI unit: one weber per ampere per metre, or equivalently one tesla metre per ampere. In practice the numbers are tiny, between 1.26 microhenries per metre for vacuum and about 0.25 H/m for the best mu-metal, which is why the micro and milli prefixes carry most of the traffic.

The conversion rule

μ = B ÷ H, μr = μ ÷ μ0, and result = value × factor(from) ÷ factor(to) with factors 1 H/m, 0.001 mH/m, 0.000001 µH/m

Permeability is flux density divided by field strength: μ = B ÷ H. A material that produces 1 T for every 1,000 A/m has a permeability of 0.001 H/m. The vacuum value is μ0 = 4π × 10−7 = 1.256637 × 10−6 H/m, the single number that anchors the whole scale.

All three units here are the same unit with prefixes, so the factors are exact powers of ten: 1 H/m = 1,000 mH/m = 1,000,000 µH/m. There is no definitional subtlety. The confusion in this topic comes from relative permeability, which is dimensionless and multiplies μ0 rather than replacing it.

Absolute versus relative permeability

Relative permeability is a pure ratio: μr = μ ÷ μ0. Air has μr = 1.0000004, a manganese-zinc ferrite 1,000 to 5,000, and electrical steel 4,000 to 8,000. Multiplying μr by 1.256637 µH/m gives the absolute value, so a ferrite at μr = 2,000 is 2.513 mH/m. Data sheets usually quote the relative figure and leave the unit off, which is where the errors start.

Worked example at the defaults

Convert 1.256637 µH/m to H/m. The from-factor is 0.000001 and the to-factor is 1, so the result is 1.256637 × 10−6 H/m. That is μ0 to seven significant figures, which is why the default is set to it.

Now scale it. A ferrite with μr = 2,000 has μ = 2,000 × 1.256637 × 10−6 = 2.513 × 10−3 H/m, or 2.513 mH/m, or 2,513 µH/m. Mu-metal at μr = 80,000 reaches 0.1005 H/m, a hundred thousand times the vacuum value.

UnitIn H/mOne H/m equals
H/m11 H/m
mH/m0.0011,000 mH/m
µH/m0.0000011,000,000 µH/m

Permeability of common materials

The absolute values below were computed from typical relative permeabilities. Treat them as order-of-magnitude figures: μr in ferromagnetic materials depends on field strength, frequency and temperature, and a single number on a data sheet is always a curve summarised as a point.

MaterialμrAbsolute μ, H/m
Vacuum11.2566 × 10−6
Air1.00000041.2566 × 10−6
Copper0.9999941.2566 × 10−6
Iron powder core10–1001.3 × 10−5 to 1.3 × 10−4
MnZn ferrite1,000–5,0001.3 × 10−3 to 6.3 × 10−3
Electrical steel4,000–8,0005.0 × 10−3 to 1.0 × 10−2
Mu-metal20,000–100,0000.025–0.126

Copper sits just below 1 because it is very weakly diamagnetic, and aluminium sits just above because it is paramagnetic. Both effects are smaller than the measurement uncertainty of most bench setups, so for coil design both metals count as vacuum and only the winding area matters.

Permeability sets inductance

Inductance of a gapped core follows from permeability and geometry: L = μ0μrN²A ÷ l. A 100-turn coil on a 100 mm² ferrite path of 50 mm at μr = 2,000 gives L = 1.2566 × 10−6 × 2,000 × 10,000 × 10−4 ÷ 0.05 = 50 mH. Halve the permeability and the inductance halves with it, which is why ferrite grade matters more than turn count once the core is chosen.

Where the conversion goes wrong

  • Entering a relative permeability such as 2,000 into a field that expects H/m, which claims a permeability a billion times too high.
  • Forgetting to multiply μr by μ0 before comparing with an absolute figure from a simulation.
  • Using 1.26 × 10−6 as μ0 and then quoting five significant figures. The exact value is 1.256637 × 10−6.
  • Treating permeability as constant. At high flux density it falls toward 1 as the core saturates.

The first item is the expensive one because it survives review. A relative value written into an absolute field produces a design with a thousand-fold error in inductance, and the resulting circuit usually fails at first power-up rather than on the bench.

Common mistakes

  • Confusing permeability with permittivity, which is the electric analogue and has units of farads per metre.
  • Assuming a ferrite quoted at μr = 5,000 keeps that value at 1 MHz, where it may fall to a few hundred.
  • Mixing the initial permeability, the amplitude permeability and the effective permeability of a gapped core.
  • Ignoring temperature, since ferrites lose permeability sharply near their Curie point.

The third item separates three different measurements that data sheets print side by side. Initial permeability is measured at very low flux, amplitude permeability at working flux, and effective permeability includes the air gap. For a gapped core the effective value can be 50 times lower than the material value, and only that one belongs in the inductance formula.

Precision and rounding

The unit factors are exact powers of ten and μ0 is exact as 4π × 10−7, so nothing in the arithmetic is approximate. Material data is the weak link, with μr tolerances of ±20 percent for ferrites and wider for powder cores. Report absolute permeability to three significant figures and always state whether a number is relative or absolute.

Frequently asked questions

What is the permeability of free space?

1.256637 × 10−6 H/m, from 4π × 10−7. That is 1.256637 µH/m or 0.001256637 mH/m.

How many µH/m are in 1 H/m?

1,000,000. The micro prefix is a factor of one million, so 0.002 H/m is 2,000 µH/m.

How do I convert relative permeability to H/m?

Multiply by μ0. A ferrite at μr = 2,000 is 2.513 × 10−3 H/m, or 2.513 mH/m.

Is 1 H/m a large permeability?

Very. It is about 800,000 times μ0, beyond any bulk material. Mu-metal at 0.1 H/m is the practical ceiling.

Why is copper below 1?

Copper is diamagnetic, with μr = 0.999994. The effect is 6 parts per million, far below the tolerance of any coil design.

What is a typical ferrite permeability?

1,000 to 5,000 for manganese-zinc grades at low frequency, and 10 to 100 for iron powder cores used in energy storage.

How does permeability affect inductance?

Directly. L = μ0μrN²A ÷ l, so a 100-turn coil on a 2,000-permeability core of 100 mm² and 50 mm path gives about 50 mH.

Does permeability change with frequency?

Yes. Ferrites lose permeability as frequency rises, often by a factor of five between 10 kHz and 1 MHz, while staying nearly flat in their intended band.

What is effective permeability?

The value that includes the air gap. A gapped core can have an effective μr of 100 even when the material itself is 2,000, and only the effective figure belongs in the inductance formula.

How accurate is the conversion?

The arithmetic is exact. The material value carries ±20 percent tolerance for ferrites, which dominates any reported permeability.

Method and sources

Calculation basis

Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: November 19, 2026
Formula & data sources
  • Linear conversion through H/m: result = value × factor(from) ÷ factor(to).
  • Factors applied: 1 mH/m = 0.001 H/m; 1 µH/m = 0.000001 H/m.
  • Every factor is an exact decimal SI prefix of the base unit, so no rounded constant is involved.
  • Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.

Cite this page

Reference formats
APA 7CalcSeed. (2026, November 19). Magnetic Permeability Converter. https://calcseed.com/c/unit/magnetic-permeability-converter/
MLA 9"Magnetic Permeability Converter." CalcSeed, 19 Nov. 2026, calcseed.com/c/unit/magnetic-permeability-converter/.
ChicagoCalcSeed. "Magnetic Permeability Converter." Last modified November 19, 2026. https://calcseed.com/c/unit/magnetic-permeability-converter/