Convert thermal conductivity between units in real time. Enter a value, choose the from and to units, and read the result instantly.

=
Thermal Conductivity Converter — convert between W/(m·K), W/(cm·K), BTU/(h·ft·°F) and more.
Result
—

What this converter returns

Thermal conductivity describes how much heat crosses a material per unit thickness, area and temperature difference. This tool converts it across four units: W/(m·K), W/(cm·K), BTU/(h·ft·°F) and kcal/(h·m·°C). The default is 1 W/(m·K) into BTU/(h·ft·°F), which returns 0.5778.

result = value × factorfrom ÷ factorto
1 W/(cm·K) = 100 W/(m·K) · 1 BTU/(h·ft·°F) = 1.730735 W/(m·K) · 1 kcal/(h·m·°C) = 1.163 W/(m·K)

Why the US factor is not a power of ten

The metric pair is trivial. A centimetre is 0.01 m, so W/(cm·K) is 100 times W/(m·K) exactly, and the stored factor of 100 needs no rounding. That conversion is a decimal shift and nothing more, which is why a ceramic quoted at 0.02 W/(cm·K) is 2 W/(m·K) and the two read the same in any sane comparison.

The BTU unit changes energy, length, time and temperature all at once. One International Table BTU is 1,055.05585262 J, one hour is 3,600 s, one foot is 0.3048 m, and one Fahrenheit degree is 5/9 K. Multiplying the denominators gives 3,600 × 0.3048 × 0.5556 = 609.63, and 1,055.0559 ÷ 609.63 = 1.73074 W/(m·K). The stored 1.730735 is rounded in the seventh digit, a relative error of 1.9 × 10−5%.

The kilocalorie unit is cleaner because the calorie is defined against the joule. One International Table kilocalorie is 4,186.8 J, so kcal/(h·m·°C) is 4,186.8 ÷ 3,600 = 1.163 W/(m·K) exactly. That is why European boiler tables stay in kcal/(h·m·°C) even when everything else has gone SI, and why 1 kcal/(h·m·°C) is very close to 1.163 W/(m·K) rather than some more awkward decimal.

Worked example at the default settings

Take 1 W/(m·K) into BTU/(h·ft·°F). The arithmetic is 1 × 1 ÷ 1.730735 = 0.577789, shown as 0.5778. Into kcal/(h·m·°C) it is 1 ÷ 1.163 = 0.859845. Into W/(cm·K) the factor of 100 gives 0.01, a shift of two places and no rounding.

Reverse the default to check the tool: 0.577789 × 1.730735 ÷ 1 = 1.0000 W/(m·K), returning exactly the input. Any converter that does not round-trip is using inconsistent factors, and this one passes because each unit is defined against the same pivot rather than against another converted unit.

Conductivity of common materials

MaterialW/(m·K)BTU/(h·ft·°F)kcal/(h·m·°C)
Copper401231.7344.8
Aluminium237136.9203.8
Carbon steel5028.943.0
Stainless steel169.2413.8
Glass1.00.5780.860
Water (20 °C)0.600.3470.516
Mineral wool0.0400.02310.0344
Air (20 °C)0.0260.01500.0224

Read the table by ratios. Copper conducts 401 ÷ 0.040 = 10,025 times better than mineral wool, and air is worse than glass by a factor of 38. That spread is the whole basis of insulation: you are not making a wall conduct less, you are trapping a low-conductivity material in a thickness that matters.

Where conductivity units decide an outcome

  • Heat sinks: an aluminium extrusion at 237 W/(m·K) versus copper at 401 is a 1.69:1 advantage, worth the cost only when the fin geometry is already at its limit.
  • Building insulation: mineral wool at 0.040 W/(m·K) in 100 mm gives R = 2.5 m²·K/W and U = 0.40 W/(m²·K).
  • Heat exchangers: stainless at 16 W/(m·K) needs about 25 times more area than copper at 401 for the same duty and wall thickness.
  • Electronics packaging: a gap filler at 3 W/(m·K) versus air at 0.026 is a 115-fold difference across the same 0.5 mm gap.
  • Cookware: an aluminium pan at 237 spreads heat far faster than a 16 W/(m·K) stainless base, which is why clad pans sandwich copper or aluminium.

The insulation row is the one to keep in your head. A 100 mm batt at 0.040 W/(m·K) gives R = 2.5 m²·K/W, so a 20 °C indoor-to-outdoor difference drives 20 ÷ 2.5 = 8 W through every square metre. Double the thickness to 200 mm and the loss halves to 4 W/m², which is why doubling insulation is usually cheaper than doubling the heating plant.

k-value, R-value and U-value are not the same number

Conductivity k is a property of the material alone. R is thickness divided by k, so it depends on how much you install. U is 1/R for the whole assembly, and it is the figure a heating engineer needs. A 0.040 W/(m·K) product at 100 mm is R-2.5 in metric; the same product at 4 inches is about R-14 in US units, and neither figure tells you the U-value until the other layers are counted.

Mistakes that shift the result

  • Dropping the per-metre basis: a quoted 0.04 W/(m·K) is not 0.04 W/(m·K·mm), and mixing the two changes an R-value by 1,000.
  • Using the cm unit by habit: 1 W/(cm·K) is 100 W/(m·K), so a value of 0.5 in cm units is a very conductive 50 W/(m·K).
  • Treating k as constant with temperature: mineral wool rises from about 0.036 to 0.045 W/(m·K) between 10 and 100 °C, a 25% change.
  • Confusing conductivity with conductance: k is per metre, while a conductance or U-value already includes thickness.

The temperature point matters more than most tables admit. Insulation datasheets quote k at a stated mean temperature, usually 10 °C or 24 °C, and a roof in summer runs far above that. Using the 10 °C figure for a hot roof overstates performance by roughly 20%, which is why manufacturers publish a curve rather than a single number.

Precision and how to quote it

Conductivity is measured, not defined, and test methods differ by several percent between laboratories. Two or three significant figures are all a datasheet supports, so a result shown as 0.577789 should be quoted as 0.578. The stored factors are exact to seven digits; the uncertainty lives in the material value, not in the conversion.

A pipe lagging check

A 50 mm layer of 0.040 W/(m·K) lagging on a hot pipe is 1.25 m²·K/W, so each square metre loses 1 ÷ 1.25 = 0.8 W per kelvin of difference. At 80 °C pipe and 20 °C air that is 48 W/m². Halving the lagging to 25 mm doubles the loss to 96 W/m², which is why lagging thickness is specified against a target loss rather than picked by eye.

Frequently asked questions

How do I convert W/(m·K) to BTU/(h·ft·°F)?

Divide by 1.730735. For example, 50 W/(m·K) ÷ 1.730735 = 28.89 BTU/(h·ft·°F), the conductivity of carbon steel.

How many W/(m·K) is 1 kcal/(h·m·°C)?

Exactly 1.163, because 4,186.8 J ÷ 3,600 s = 1.163 W/(m·K). The conversion is exact to the definition of the International Table calorie.

What is 1 W/(cm·K) in W/(m·K)?

100, exactly. A centimetre is 0.01 m, so the per-centimetre unit is 100 times larger and a value of 0.02 W/(cm·K) is 2 W/(m·K).

What is the thermal conductivity of copper?

About 401 W/(m·K), which is 231.7 BTU/(h·ft·°F) or 344.8 kcal/(h·m·°C).

Why is the BTU conversion factor so awkward?

It combines four unit changes: BTU to joules, hour to seconds, foot to metres and Fahrenheit to kelvin. The result is 1,055.0559 ÷ 609.63 = 1.730735.

How do I get an R-value from thermal conductivity?

Divide thickness in metres by k. A 0.040 W/(m·K) insulation at 100 mm gives R = 0.1 ÷ 0.04 = 2.5 m²·K/W, and U = 1/R = 0.40 W/(m²·K).

How much better is copper than stainless steel?

401 against 16 W/(m·K) is a factor of 25. A heat exchanger in stainless needs about 25 times the area of a copper one for the same duty and wall thickness.

Does thermal conductivity change with temperature?

Yes. Insulation rises from about 0.036 to 0.045 W/(m·K) between 10 and 100 °C, and gases rise faster than metals. Use a value at the mean operating temperature.

What is the conductivity of air and why does it matter?

About 0.026 W/(m·K), which is 0.0150 BTU/(h·ft·°F). It is the reason foams and batts work: they hold still air in small cells and stop convection from carrying heat.

Method and sources

Calculation basis

Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: November 19, 2026
Formula & data sources
  • Linear conversion through W/(m·K): result = value × factor(from) ÷ factor(to).
  • Factors applied: 1 W/(cm·K) = 100 W/(m·K); 1 BTU/(h·ft·°F) = 1.730735 W/(m·K); 1 kcal/(h·m·°C) = 1.163 W/(m·K).
  • Watts per centimetre-kelvin is an exact power of ten and the kilocalorie factor is exactly 1.163 from the International Table calorie. BTU per hour-foot-°F uses the International Table BTU, the international foot and 5/9 kelvin per Fahrenheit degree, and is stored rounded.
  • The SI prefixes are exact; the BTU/(h·ft·°F) factor is stored as a rounded decimal, the largest deviation being 1.9e−5% relative. A result carries that rounding on top of floating-point arithmetic.