R-Value Converter
Convert thermal insulance (R-value) between units in real time. Enter a value, choose the from and to units, and read the result instantly.
What this converter returns
You enter an R-value in one unit system and the page returns the same insulation resistance in the other. The metric unit is m²·K/W, which European datasheets also call RSI; the imperial unit is ft²·°F·h/BTU, the number printed on every batt in a US building supply aisle. At the defaults, 3.5 m²·K/W comes back as 19.87 ft²·°F·h/BTU.
The conversion
One imperial R unit is one square foot of area, one hour of time, one Fahrenheit degree of temperature difference, per British thermal unit of heat flow. Written out, that is ft²·°F·h/BTU, and it describes resistance rather than conductance, so bigger is better insulation.
Where 0.17611 comes from
Rebuild the factor from SI definitions: 1 hour is 3,600 s, 1 ft² is 0.09290304 m², a 1 °F difference is 5/9 K, and the International Table BTU is 1,055.05585 J. Multiply through: 3,600 × 0.09290304 × (5/9) ÷ 1,055.05585 = 0.176110 m²·K/W. The tool stores that constant at five decimals, so a converted result carries a relative error under 0.0001 percent.
Inverting it gives 1 m²·K/W = 5.67827 ft²·°F·h/BTU. Because both units start at zero, the two scales are strictly proportional — no offset term appears anywhere. Doubling the metric value doubles the imperial one, which is not true of temperature or gauge scales.
Worked example at the defaults
The default is 3.5 m²·K/W converting to imperial: 3.5 ÷ 0.17611 = 19.87. A European wall spec of 3.5 therefore describes the same assembly as a US label of R-19.9, a little better than the R-19 batts sold for 2×6 framing.
Run the arithmetic backwards and the same identity holds: 38 × 0.17611 = 6.69 m²·K/W, so an R-38 attic is a 6.69 metric assembly. That is roughly 300 mm of blown mineral wool at λ = 0.044 W/m·K, since 0.300 ÷ 0.044 = 6.82. The two answers agree because they describe the same thickness of the same material.
R-values you meet in a house
| US label | m²·K/W | Where it is used |
|---|---|---|
| R-11 | 1.937 | 2×4 wall, low-density batt |
| R-13 | 2.289 | 2×4 wall, standard batt |
| R-15 | 2.642 | 2×4 wall, high-density batt |
| R-19 | 3.346 | 2×6 wall |
| R-21 | 3.698 | 2×6 wall, high-density |
| R-30 | 5.283 | attic floor, cathedral ceiling |
| R-38 | 6.692 | attic, cold climate |
| R-49 | 8.629 | attic, very cold climate |
Read the table with one rule: multiply the left column by 0.17611 to reach the middle, divide to come back. Every row checks out that way — 19 × 0.17611 = 3.346, and 8.629 ÷ 0.17611 = 49.0.
The same insulation described three ways
R-value, RSI and lambda
Conductivity λ (W/m·K) is a material property; resistance is what you build with it: R = thickness ÷ λ. A 100 mm mineral wool batt at λ = 0.035 gives 0.100 ÷ 0.035 = 2.857 m²·K/W, which is 16.2 imperial — R-16 in a 4-inch cavity, noticeably better than the R-13 label you would expect from the same depth of fiberglass.
U-value is the reciprocal and runs the other way: 1 ÷ 2.289 m²·K/W = 0.437 W/m²·K for an R-13 wall, or 0.0769 BTU/h·ft²·°F. A window rated U-0.30 in imperial terms is R-3.3, or 0.587 m²·K/W. Putting a U-0.30 window into an R-13 wall means most of the heat leaves through the glass, not the studs.
What moves the number
- Thickness moves R linearly, so doubling a batt from 89 mm to 178 mm doubles resistance from 2.29 to 4.58 m²·K/W.
- Material conductivity sets the per-inch return: fiberglass runs about R-3.1–3.4 per inch, extruded polystyrene 5.0, polyisocyanurate 5.6–6.5. That spread is λ = 0.044 against 0.029 W/m·K.
- Framing interrupts the cavity. Studs at 16 in on centre displace 15–25 percent of the area, and a stud is about R-1.0 per inch, so a nominal R-19 wall measures near R-16 whole-wall.
- Air films add resistance outside the material: about 0.12 m²·K/W indoors and 0.03 outdoors, roughly 0.85 imperial R combined, and they change with wind and surface finish.
- Moisture degrades fibrous insulation quickly. A damp batt reads far below its label, which is why a wall that tests at R-19 in a dry climate tests lower after a roof leak.
Mistakes that produce a wrong number
- Reading “R-13” as 13 m²·K/W. It is 2.289 — an error of a factor of 5.7, which would make a wall look like a passive house.
- Confusing R per inch with total R. A 3.5-inch batt at R-3.7 per inch is R-13 total, not R-3.7.
- Adding a metric number to an imperial one in a spreadsheet, then wondering why the total exceeds every product on the market.
- Quoting cavity R as assembly R, which ignores studs, plates, headers and the air films that a whole-wall calculation includes.
All four are unit errors rather than arithmetic errors, and each has a cheap check. If a single residential wall converts to more than 8 m²·K/W, you divided when you should have multiplied — only a thick roof or a vacuum panel reaches that territory.
Precision and where the stored factor bites
The factor is held at 0.17611 rather than the full 0.1761102. Converting R-49 gives 8.629 where the unrounded constant gives 8.6294; the fifth digit is the first to drift, and across a whole envelope the difference is under 0.02 m²·K/W, well inside the tolerance of any installed batt.
Hand conversion is where rounding actually costs something. Take R-19 to 3.35, then back: 19.02. Two roundings at two decimals are harmless. Round to one decimal — 3.3 — and the round trip returns 18.74, a quarter of an R lost to a pencil. Keep the intermediate value at four significant figures and round only the answer you publish.
Frequently asked questions
How do I convert an R-value to metric?
Multiply the imperial R-value by 0.17611. R-13 becomes 2.289 m²·K/W, R-19 becomes 3.346, and R-38 becomes 6.692.
What is 3.5 m²·K/W in R-value?
Divide by 0.17611 to get 19.87, which is about R-20. That is slightly better than a standard R-19 2×6 batt.
Is RSI the same as R-value?
RSI is the metric R-value in m²·K/W, so yes — the same quantity in different units. RSI 2.29 and R-13 describe the same wall.
How many m²·K/W is R-38 attic insulation?
6.692 m²·K/W, which is about 300 mm of blown mineral wool at λ = 0.044 W/m·K.
Why is one imperial R unit only 0.176 m²·K/W?
Because the imperial unit is built from a square foot and a Fahrenheit degree: 3,600 s × 0.0929 m² × 5/9 K ÷ 1,055.06 J = 0.17611 m²·K/W. The small number reflects a small area and a small temperature step, not a weak insulation.
What is the difference between R-value and U-value?
They are reciprocals. An R-13 wall has R = 2.289 m²·K/W and U = 0.437 W/m²·K; multiply the two and you get 1.0. Add U-values in parallel paths, add R-values for layers in series.
Can I add R-values of separate layers?
Yes, for layers in series. A 2.289 cavity plus 0.880 of polyiso plus 0.15 of air films gives about 3.32 m²·K/W, or R-18.9 — and the figure is only valid if the foam is continuous, with no studs bridging it.
Which is better, R-19 or 3.3 m²·K/W?
R-19 equals 3.346 m²·K/W, so 3.3 is just under it — a difference of about 1.4 percent, invisible in a real wall.
How thick is an R-13 fiberglass batt?
89 mm (3.5 in), because those batts run about R-3.7 per inch: 13 ÷ 3.5 = 3.71. A low-density batt of the same R-value would need about 4.2 inches.
Method and sources
- Linear conversion through m²·K/W: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 ft²·°F·h/BTU = 0.17611 m²·K/W.
- The R-value factor is the reciprocal of the BTU per hour-square foot-°F conductance: 3600 s/h times 0.09290304 m²/ft² times 5/9 K per °F, divided by the International Table BTU. It is stored rounded.
- The SI prefixes are exact; the ft²·°F·h/BTU factor is stored as a rounded decimal, the largest deviation being 1.0e−4% relative. A result carries that rounding on top of floating-point arithmetic.