Thermal Expansion Converter
Convert thermal expansion coefficient between units in real time. Enter a value, choose the from and to units, and read the result instantly.
What this converter returns
The coefficient of thermal expansion tells you what fraction of its length a material gains for each degree of temperature rise. This page converts between 1/K, 1/°C, 1/°F and µm/(m·°C). At the defaults it turns 12 µm/(m·°C) into 1.2 × 10−5 /°C, the expansion of ordinary structural steel.
The numbers are small, which is why the industry writes them in parts per million rather than as decimals. Steel at 12 ppm/K means one metre grows 12 micrometres per kelvin, or 12 millimetres over a kilometre for a 1,000 K rise. Small per degree, but decisive over long spans and large temperature swings.
The conversion rule
Expansion is proportional to original length and to the temperature change: ΔL = αLΔT. That fixes the unit as a pure reciprocal temperature, because the lengths cancel. A coefficient of 1.2 × 10−5 /°C applied to 10 m and 30 °C gives 1.2 × 10−5 × 10 × 30 = 3.6 mm.
The per-kelvin and per-Celsius factors are both 1 because a kelvin and a Celsius degree are the same size and only differences enter. The per-Fahrenheit factor is 1.8, because one Celsius degree spans 1.8 Fahrenheit degrees. The micrometre-per-metre-per-degree unit is 10−6 /°C, since a micrometre is a millionth of a metre.
Why the Fahrenheit number is not smaller
A Fahrenheit degree is smaller than a Celsius degree, so each one produces less expansion. The coefficient expressed per °F is therefore numerically smaller: steel at 12 ppm/°C is 6.67 ppm/°F. The factor of 1.8 works in the direction people usually get backwards, because the unit in the denominator shrank while the coefficient had to describe the same physical material.
Worked example at the defaults
Convert 12 µm/(m·°C) to 1/°C. Multiplying by 0.000001 gives 1.2 × 10−5 /°C, or 12 ppm/K. In Fahrenheit units the same steel is 12 ÷ 1.8 = 6.67 × 10−6 /°F.
Now put it to work. A 30 m steel bridge expands 1.2 × 10−5 × 30 × 40 = 14.4 mm across a 40 K swing, which is why bridges carry expansion joints of that order. A 2 m aluminium window frame at 23 ppm/K grows 23 × 10−6 × 2 × 35 = 1.6 mm between a cold night and a hot afternoon.
| Unit | In 1/K | One 1/K equals |
|---|---|---|
| 1/K | 1 | 1 1/K |
| 1/°C | 1 | 1 1/°C |
| 1/°F | 1.8 | 0.5556 1/°F |
| µm/(m·°C) | 0.000001 | 1,000,000 µm/(m·°C) |
Expansion of common materials
The table gives linear coefficients at room temperature. The spread from Invar to lead is a factor of 25, which is what makes material pairing a design decision rather than a detail.
| Material | ppm/K | 1/°C | ppm/°F |
|---|---|---|---|
| Invar 36 | 1.2 | 1.2 × 10−6 | 0.67 |
| Borosilicate glass | 3.3 | 3.3 × 10−6 | 1.83 |
| Concrete | 10 | 1.0 × 10−5 | 5.6 |
| Carbon steel | 12 | 1.2 × 10−5 | 6.7 |
| Copper | 17 | 1.7 × 10−5 | 9.4 |
| Aluminium | 23 | 2.3 × 10−5 | 12.8 |
| Lead | 29 | 2.9 × 10−5 | 16.1 |
Matching coefficients is the whole art of joining dissimilar materials. Borosilicate glass at 3.3 ppm/K seals to tungsten at 4.5 ppm/K well enough for lamp envelopes, while soda-lime glass at 9 ppm/K does not, and the seal cracks on the first thermal cycle. The same logic governs ceramic-to-metal feedthroughs and semiconductor packages.
Bimetallic strips and constrained expansion
Bond two metals with different coefficients and the pair bends on heating, which is the principle of the bimetallic thermostat. The deflection is proportional to the difference in coefficients, so steel and copper at 12 and 17 ppm/K give a 5 ppm/K differential, enough to switch a contact over a 20 K swing. The same differential, when it cannot bend, becomes stress: a fully constrained steel bar heated 100 K develops about 250 MPa, since 200 GPa × 1.2 × 10−5 × 100 = 240 MPa.
Where the conversion goes wrong
- Multiplying by 1.8 when converting to per-°F. The correct direction divides, so 12 ppm/°C is 6.67 ppm/°F, not 21.6.
- Using a Celsius coefficient with a Fahrenheit temperature change, which overstates expansion by 1.8.
- Treating the coefficient as constant over a wide range. Aluminium rises about 5 percent between 0 and 200 °C.
- Applying a linear coefficient to a polymer part, where mould shrinkage and moisture movement can exceed thermal expansion.
The second item is the practical one on US drawings: a length in inches, a temperature change in Fahrenheit degrees and a coefficient in ppm/K. Convert the temperature difference first, or convert the coefficient to per-°F, but never mix the two inside the same multiplication.
Common mistakes
- Confusing linear expansion with volumetric expansion, which is roughly three times larger for an isotropic solid.
- Forgetting that the coefficient refers to the original length, not the heated length, when the rise is large.
- Assuming a composite expands like its matrix and ignoring fibre direction.
- Dropping the micro prefix and treating 12 µm/(m·°C) as 12 /°C.
The volumetric point matters for castings and for liquid-filled vessels: a solid cube at 12 ppm/K expands about 36 ppm/K in volume, so a 1 m³ block gains 36 cm³ per kelvin. Liquids are worse, with water near 200 ppm/K and oils near 700 ppm/K.
Precision and rounding
The unit factors are exact, with 1/°F equal to 1.8/°C by definition. Material values carry more uncertainty than the conversion, typically ±5 percent between handbooks and wider between batches. Report coefficients in whole ppm/K, as in 12 ppm/K or 23 ppm/K, and give the temperature range they apply to.
Frequently asked questions
How do I convert µm/(m·°C) to 1/°C?
Multiply by 0.000001. Steel at 12 µm/(m·°C) is 1.2 × 10−5 /°C, or 12 ppm/K.
How many ppm per °F is 12 ppm/K?
6.67. Divide by 1.8, because a Fahrenheit degree is smaller and therefore produces less expansion per degree.
Is 1/K the same as 1/°C?
Yes, exactly. A kelvin and a Celsius degree are the same size and the coefficient uses only differences.
How much does a 10 m steel beam grow in 30 °C?
3.6 mm, from 1.2 × 10−5 × 10 × 30. A 30 m span over 40 K grows 14.4 mm.
Why is the per-°F coefficient smaller?
Because each Fahrenheit degree represents less temperature change. The same material property restated per °F is 1.8 times smaller in numerical value.
What is the expansion coefficient of aluminium?
About 23 ppm/K, or 2.3 × 10−5 /°C, and 12.8 ppm/°F. That is nearly double steel at 12 ppm/K.
Which material hardly expands at all?
Invar 36, at about 1.2 ppm/K, roughly a tenth of steel. Borosilicate glass at 3.3 ppm/K is the common low-expansion alternative for optics.
How do I find the stress from constrained expansion?
Multiply the modulus by the coefficient and the temperature change. Steel at 200 GPa, 12 ppm/K and 100 K develops about 240 MPa.
Is volumetric expansion three times linear?
For an isotropic solid, yes, to first order. A material at 12 ppm/K expands about 36 ppm/K in volume.
How accurate is the conversion?
The factors are exact, with 1.8 fixed by the degree definitions. Handbook values vary by about 5 percent, so whole ppm/K is the right precision.
Method and sources
- Linear conversion through 1/K: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 1/°C = 1 1/K; 1 1/°F = 1.8 1/K; 1 µm/(m·°C) = 0.000001 1/K.
- Every factor is exact: a 1 °C interval equals 1 K, a 1 °F interval is 5/9 K (so its reciprocal is 1.8), and micrometres per metre-°C is 10⁻⁶ per kelvin.
- Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.