Section Modulus Converter
Convert section modulus between units in real time. Enter a value, choose the from and to units, and read the result instantly.
What section modulus measures
Section modulus is the geometric property that converts a bending moment into a stress: S = I ÷ c, where I is the second moment of area and c is the distance from the neutral axis to the extreme fibre. Its SI unit is the cubic metre (m³), though practical sections are quoted in cm³ or in³.
The unit is a length cubed because bending stress scales with the square of depth and linearly with width. Doubling a beam’s depth quadruples its section modulus, which is why depth buys strength far more cheaply than width.
The conversion rule
The cubic inch factor is exact: 25.4 mm cubed is 16,387.064 mm³, which is 16.387064 cm³ or 1.6387064 × 10⁻⁵ m³. Nothing is rounded in that chain, so a conversion between cm³ and in³ is a division by 16.387064.
Engineers work in cm³ for metric steel tables and in³ for US shapes, so the pair dominates practice. One cubic metre is a million cm³, which means an SI figure for a real beam is always a small decimal and the prefixed unit is the readable one.
Worked example: 100 cm³
The defaults convert 100 cm³ to in³. Divide by 16.387064: 6.10 in³. The reverse, 6.10 × 16.387 = 100.0 cm³, closes the loop.
A 100 mm diameter solid circle has S = πd³ ÷ 32 = 98,175 mm³, which is 98.2 cm³ or 5.99 in³. That is a solid round bar of respectable size, and it shows how modest the numbers are for compact sections compared with rolled shapes.
Conversion table
| cm³ | in³ | m³ |
|---|---|---|
| 10 | 0.610 | 0.00001 |
| 50 | 3.051 | 0.00005 |
| 100 | 6.102 | 0.0001 |
| 500 | 30.512 | 0.0005 |
| 1,000 | 61.024 | 0.001 |
The 500 cm³ row is a small rolled I-beam; 1,000 cm³ is 61 in³, close to a W10×49 bending about its strong axis. Residential timber joists sit far lower, often between 100 and 400 cm³.
Where the conversion is used
Steel catalogues, timber span tables and cold-formed design guides all publish section modulus, but not in the same unit.
- Structural steel selection, where US shapes list Sx and Sy in in³ and metric tables in cm³.
- Timber joist sizing, where span tables use either unit depending on the publisher.
- Cold-formed steel studs, where the effective section modulus accounts for local buckling.
- Mezzanine and racking design, where imported profiles arrive with metric datasheets.
From section modulus to bending stress
Stress is moment divided by section modulus. A 20 kN·m moment on a 100 cm³ section gives σ = 20,000 N·m ÷ 0.0001 m³ = 200 MPa. Against a 250 MPa yield strength that is a utilisation of 0.8, which passes but leaves little room for deflection limits or load factors.
Strong axis and weak axis
Every asymmetric section has two values. A 2×10 joist has Sx near 350 cm³ about its strong axis and Sy near 57 cm³ about the weak axis, a ratio of about six. Loading the joist on its flat would cut capacity by that factor.
Conversions do not change the axis, only the unit, so a table of Sx values stays a table of Sx values after conversion. The mistake to watch for is comparing a strong-axis figure in in³ against a weak-axis figure in cm³, which can hide a sixfold difference behind numbers that look similar.
Precision and common mistakes
- Confusing cm³ with mm³; there are 1,000 mm³ in a cm³, a factor-of-1,000 error.
- Reading a second moment of area in cm⁴ as a section modulus in cm³.
- Using an elastic section modulus for a plastic-design check that needs the plastic modulus Z.
- Converting a nominal shape name (2×10) instead of the actual dressed dimensions.
Strength and stiffness are different checks
Section modulus governs bending stress; the second moment of area governs deflection. A beam can pass the stress check and still sag beyond L/360, and the two properties are quoted in different units, cm³ against cm⁴.
A 4 m simply supported span carrying 10 kN/m with I = 4,100 cm⁴ and E = 200 GPa deflects 5wL⁴ ÷ (384EI) = 5 × 10,000 × 256 ÷ (384 × 2 × 10⁷⁺ × 4.1 × 10⁻⁵) = 4.1 mm. The L/360 limit is 11.1 mm, so it passes comfortably, even though its 350 cm³ modulus is what limits the load.
Unit consistency is easier to keep in one system. A 20 kN·m moment is 177 kip-in, and dividing by 6.10 in³ gives 29.0 ksi, which is 200 MPa. The same 200 MPa appears whether you work entirely in SI or entirely in imperial, but mixing 100 cm³ with kip-in gives an answer wrong by a factor of 16.
Design codes also distinguish gross and effective section modulus. A cold-formed stud with slender flanges buckles locally, so its effective modulus can be 20 to 40 percent below the gross value, and using the gross figure overstates capacity by roughly a third. The unit conversion is the same either way, but the number you start from has to be the right one.
A quick check
One in³ is 16.39 cm³, so multiply cm³ by 0.061 to reach in³ and by 16.39 to come back. For a quick estimate, divide cm³ by 16 and add 2 percent: 200 cm³ is 12.2 in³, and the rough rule gives 12.5.
Frequently asked questions
How many in³ is 100 cm³?
6.102 in³. One inch is 2.54 cm, so a cubic inch is 16.387064 cm³, and 100 ÷ 16.387 = 6.102.
How many cm³ is 1 in³?
16.387064 cm³ exactly, since 2.54³ = 16.387064. A 10 in³ shape is 163.9 cm³.
Is section modulus the same as moment of inertia?
No. Section modulus is inertia divided by the distance to the extreme fibre, so it carries cm³ while inertia carries cm⁴. A 2×10 joist has I near 4,100 cm⁴ and S near 350 cm³.
How do I get bending stress from section modulus?
Divide the moment by S. A 20 kN·m moment on 100 cm³ gives 200 MPa, because 20,000 N·m ÷ 0.0001 m³ = 2 × 10⁸ Pa.
Why does doubling depth increase strength so much?
Because S scales with depth squared. Doubling depth from 100 to 200 mm takes S from 100 to 400 cm³ for the same width, a fourfold gain in bending capacity.
What is the section modulus of a rectangle?
S = bd² ÷ 6. For a 100 mm wide, 200 mm deep section that is 100 × 40,000 ÷ 6 = 666,667 mm³, or 667 cm³.
How many cm³ is a W10×49?
About 895 cm³, since Sx is 54.6 in³ and 54.6 × 16.387 = 895. The weak axis is far lower, at 18.7 in³, or 306 cm³.
Does the unit change the utilisation check?
No, as long as moment and modulus use consistent units. Converting 100 cm³ to 6.10 in³ and the moment to kip-in gives the same stress ratio.
How accurate is the in³ factor?
Exact. The inch is defined as 25.4 mm, so 2.54³ gives 16.387064 with no rounding beyond the printed decimals.
Method and sources
- Linear conversion through m³: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 cm³ = 0.000001 m³; 1 in³ = 0.000016387064 m³.
- The cubic centimetre is an exact power of ten, and the cubic inch is exactly 0.0254³ = 1.6387064 × 10⁻⁵ m³ from the international inch.
- Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.