What this converter returns

Kinematic viscosity is dynamic viscosity divided by density, so it measures how freely a fluid spreads under gravity rather than how hard it resists shear. This tool converts across four units: m²/s, centistokes, stokes and ft²/s. The default is 0.000001 m²/s into cSt, which returns 1 cSt, the viscosity of water at about 20 °C.

result = value × factorfrom ÷ factorto
1 cSt = 1 mm²/s = 10−6 m²/s · 1 St = 1 cm²/s = 10−4 m²/s · 1 ft²/s = 0.09290304 m²/s

Where the four factors come from

The stoke is a CGS unit defined as one square centimetre per second, and a square centimetre is 10−4 m², so 1 St is exactly 0.0001 m²/s. The centistoke is one hundredth of a stoke, which works out to 10−6 m²/s, and that is identical to one square millimetre per second. The identity is worth memorizing: cSt and mm²/s are the same unit, and oil datasheets switch between them without comment.

The square foot per second follows from the international foot, 0.3048 m, squared to 0.09290304 m²/s. There is no time conversion because both the metric and the US unit are per second. That leaves one awkward factor and three exact ones, which is the reverse of the thermal-conductivity converter where the US unit carries all the mess.

Kinematic is dynamic divided by density

The relation is ν = μ ÷ ρ. Water at 20 °C has a dynamic viscosity of 0.001 Pa·s and a density of 998 kg/m³, so its kinematic viscosity is 0.001 ÷ 998 = 1.002 × 10−6 m²/s, or about 1.002 cSt. Oil with the same 0.001 Pa·s dynamic viscosity but a density of 850 kg/m³ would be 1.18 cSt, which is why the two viscosities are not interchangeable in pipe calculations.

Worked example at the default settings

Take 0.000001 m²/s into cSt. The arithmetic is 0.000001 × 1 ÷ 0.000001 = 1 cSt. Into stokes it is 0.000001 ÷ 0.0001 = 0.01 St, and into ft²/s it is 0.000001 ÷ 0.09290304 = 0.000010764 ft²/s, a number small enough that no US oil datasheet would print it.

Try an oil instead. ISO VG 46 hydraulic oil is 46 cSt at 40 °C, which is 46 × 10−6 = 0.000046 m²/s and 0.46 St. The grade number in the ISO VG system is literally the viscosity in cSt at 40 °C, rounded to the nearest standard grade, which is why VG 46 is 46 cSt and not 45 or 47.

Viscosities in everyday fluids

FluidcStm²/sft²/s
Air (20 °C)151.5 × 10−51.6 × 10−4
Water (20 °C)1.01.0 × 10−61.08 × 10−5
SAE 30 at 100 °C111.1 × 10−51.18 × 10−4
ISO VG 46 at 40 °C464.6 × 10−54.95 × 10−4
Glycerol (20 °C)1,1801.18 × 10−31.27 × 10−2
Honey (20 °C)3,0003.0 × 10−33.23 × 10−2

The range from air at 15 cSt to honey at 3,000 cSt is only a factor of 200, which is why one unit serves the whole field. Dynamic viscosity spans a wider range and needs the poise and centipoise in the same way, but the shape of the problem is identical: pick the unit that keeps the printed number readable.

Where kinematic viscosity decides an outcome

  • Pipe flow: Reynolds number is Re = v·D ÷ ν, so water at 1 m/s in a 50 mm pipe gives 1 × 0.05 ÷ 1.0 × 10−6 = 50,000, firmly turbulent.
  • Lubrication: the same pipe with VG 46 oil at 1 m/s gives 0.05 ÷ 4.6 × 10−5 = 1,087, which is laminar and changes the pressure-drop formula entirely.
  • Oil grading: ISO VG numbers are cSt at 40 °C, so VG 32, VG 46 and VG 68 are 32, 46 and 68 cSt by definition.
  • Fuel injection: diesel at 3–4 cSt at 40 °C atomises well, and cold fuel at 20 cSt sprays as a stream rather than a mist.
  • Coating and printing: ink viscosity is controlled in cSt or in Saybolt seconds, and a 10% drift changes coat weight visibly.

The lubrication row is why the same pipe can be turbulent or laminar depending on what flows through it. Pressure drop scales roughly with velocity squared in turbulent flow and linearly in laminar flow, so the crossover at Re = 2,300 changes the pump curve, not just a constant. Getting the viscosity unit wrong by a factor of 1,000 moves that crossover by three orders of magnitude.

Viscosity index and why grades are quoted at 40 °C

Oil thins as it heats, and the rate of thinning is summarized by the viscosity index. A high-index oil might fall from 46 cSt at 40 °C to 9 cSt at 100 °C, a ratio of 5.1, while a low-index oil of the same grade might fall to 7 cSt, a ratio of 6.6. Both pass the grade test at 40 °C and behave differently in a hot bearing, which is why a single viscosity figure never describes an oil completely.

Mistakes that shift the number

  • Confusing stoke with centistoke: the factor is 100, so 46 cSt is 0.46 St, not 46 St.
  • Using cSt where Pa·s is needed: multiply by density, so 46 cSt of 850 kg/m³ oil is 0.0391 Pa·s.
  • Ignoring temperature: VG 46 oil is 46 cSt at 40 °C but nearer 8 cSt at 100 °C, an 83% drop.
  • Treating mm²/s as a different unit from cSt: they are identical, and converting between them should return the same number.

The density step is the one that catches people moving from oil data to a CFD model. Solvers usually want dynamic viscosity in Pa·s, while the datasheet gives kinematic in cSt. Multiply by density in kg/m³ and by 10−6 for the cSt, so 46 cSt at 850 kg/m³ is 46 × 10−6 × 850 = 0.0391 Pa·s.

Precision and rounding

The stoke and centistoke factors are exact, and the square foot factor is exact from the 1959 definition, so the conversion itself introduces no error. Viscosity measurement is another matter: a glass capillary tube is good to about 0.5%, and a rotational viscometer to 1–2%. Quoting 1.002 cSt from a nominal 1 cSt input overstates what any bench test can confirm.

A bearing oil check

A journal bearing running at 1,500 rpm with a 50 mm diameter has a surface speed of π × 0.05 × 25 = 3.93 m/s. With VG 46 oil at its 40 °C figure, the Sommerfeld number and the film thickness both depend on ν, and a drop from 46 to 8 cSt at operating temperature cuts the film by roughly the same ratio, which is why bearing clearances are specified against hot viscosity rather than the grade on the drum.

Frequently asked questions

How do I convert m²/s to cSt?

Multiply by 1,000,000. For example, 0.000046 m²/s is 46 cSt, the grade of ISO VG 46 oil at 40 °C.

Is 1 cSt the same as 1 mm²/s?

Yes, exactly. A centistoke is 10−6 m²/s and a square millimetre per second is also 10−6 m²/s, so the numbers are identical.

How many cSt are in 1 stoke?

Exactly 100. One stoke is 1 cm²/s and one centistoke is 1 mm²/s, and 1 cm² is 100 mm².

What is the kinematic viscosity of water?

About 1.0 cSt at 20 °C, which is 1.0 × 10−6 m²/s. It falls to 0.55 cSt at 40 °C and 0.29 cSt at 100 °C.

What does ISO VG 46 mean?

The oil has a kinematic viscosity of 46 cSt at 40 °C, which is 4.6 × 10−5 m²/s. The grade number is the viscosity itself, rounded to a standard step.

How do I convert cSt to Pa·s?

Multiply by density and by 10−6. For 46 cSt at 850 kg/m³: 46 × 10−6 × 850 = 0.0391 Pa·s.

How do I convert ft²/s to m²/s?

Multiply by 0.09290304. One square foot per second is exactly that many square metres per second, because the foot is 0.3048 m and 0.3048² = 0.09290304.

Why does viscosity fall when oil heats up?

Warmer molecules move more freely, so shear resistance drops. VG 46 oil falls from 46 cSt at 40 °C to around 8 cSt at 100 °C, which is why hot-bearing performance is not predicted by the grade alone.

How is kinematic viscosity used in pipe sizing?

Through the Reynolds number, Re = v·D/ν. Water at 1 m/s in a 50 mm pipe gives Re = 50,000 and turbulent flow; VG 46 oil under the same conditions gives Re = 1,087 and laminar flow.

Method and sources

Calculation basis

Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: November 19, 2026
Formula & data sources
  • Linear conversion through m²/s: result = value × factor(from) ÷ factor(to).
  • Factors applied: 1 Centistoke (cSt) = 0.000001 m²/s; 1 Stoke (St) = 0.0001 m²/s; 1 ft²/s = 0.09290304 m²/s.
  • The stoke and centistoke are exact CGS definitions (1 St = 10⁻⁴ m²/s), and the square foot per second is exactly 0.09290304 m²/s.
  • Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.