Radiation Dose Converter
Convert radiation absorbed dose between units in real time. Enter a value, choose the from and to units, and read the result instantly.
What this converter returns
Absorbed dose is the energy radiation deposits in matter, measured per kilogram of tissue. This tool converts it across four units: gray, milligray, rad and millirad. The default is 1 Gy into rad, which returns 100 rad, and that factor of 100 is the single most useful number on this page because medical physics still quotes doses in both systems.
1 Gy = 1 J/kg · 1 mGy = 0.001 Gy · 1 rad = 0.01 Gy · 1 mrad = 10−5 Gy = 0.01 mGy
Why the factor is 100 rather than 1,000
The gray is the SI unit and is defined as one joule of absorbed energy per kilogram of matter, so its factor is 1. It is named after Louis Harold Gray, who worked out how to measure energy deposition in tissue. The rad, short for radiation absorbed dose, is the older CGS unit and was defined as 100 erg per gram. Since 1 erg is 10−7 J and there are 1,000 g in a kilogram, 100 erg/g is 0.01 J/kg, exactly 0.01 Gy.
That history is why the conversion is exactly 100 rather than a power of ten: the rad was built from centimetres and grams and the gray from metres and kilograms, so two decimal steps appear at once and cancel into a hundred. The prefixes on top are ordinary SI ones, so 1 mGy is 0.001 Gy and 1 mrad is 0.00001 Gy, which makes 1 mGy exactly 100 mrad.
Conversion factors
Worked example at the default settings
Take 1 Gy into rad. The arithmetic is 1 × 1 ÷ 0.01 = 100 rad. The same dose in the other units: 1,000 mGy and 100,000 mrad. Everything is a power of ten once you are inside one system, which is why the only conversion worth memorizing is the 100:1 bridge between gray and rad.
Now a clinically realistic figure. A chest CT delivers about 7 mGy, which is 0.007 Gy, 0.7 rad or 700 mrad. A dental bitewing at 0.005 mGy is 0.5 mrad, two thousand times smaller. That span, from half a millirad to a hundred thousand millirad, is why radiographers change units rather than write long strings of zeros.
Doses you can compare against
| Exposure | mGy | rad | mrad |
|---|---|---|---|
| Dental bitewing | 0.005 | 0.0005 | 0.5 |
| Chest X-ray, 2 views | 0.1 | 0.01 | 10 |
| Mammogram | 0.4 | 0.04 | 40 |
| Chest CT | 7 | 0.7 | 700 |
| Annual background (US) | 2.4 | 0.24 | 240 |
| Acute syndrome threshold | 1,000 | 100 | 100,000 |
| 50% lethal whole-body dose | 4,000 | 400 | 400,000 |
| Radiotherapy course | 60,000 | 6,000 | 6,000,000 |
The radiotherapy row explains why the units look alarming out of context. A curative course delivers about 60 Gy to a tumour, but it is fractionated into 30 or so doses of 2 Gy aimed at a small volume, so healthy tissue sees far less. Reading 60,000 mGy without the fractionation detail suggests a lethal exposure, which it would be if it arrived all at once and to the whole body.
Where absorbed dose units decide an outcome
- Medical imaging: dose reports often give mGy while the referral guideline is written in mSv, and for photons the two are numerically equal.
- Radiation therapy: prescription and planning systems work in Gy, while older linac documentation and some protocols still list rad.
- Occupational monitoring: dosimeters read in mSv, but a neutron or proton field needs the absorbed dose in Gy converted with a quality factor.
- Food irradiation: allowed doses are written in kGy, where 10 kGy is 1 Mrad, a unit combination that catches people out.
- Emergency response: triage thresholds are in Gy, and 1 Gy of whole-body dose is where acute radiation syndrome begins.
The food irradiation row is a good test of unit discipline. A 10 kGy treatment is 10,000 Gy and also 1 million rad, or 1 Mrad, and old US regulations still use the Mrad figure. Nothing about the physics changed between the two documents; only the century in which they were written.
Gray is absorbed dose, sievert is equivalent dose
The gray measures energy deposited per kilogram and says nothing about biological harm. The sievert multiplies by a radiation weighting factor: 1 for X-rays and gamma, 1 for electrons, and 20 for alpha particles. A 1 Gy alpha dose therefore equals 20 Sv of equivalent dose, while 1 Gy of gamma equals 1 Sv. Confusing the two understates an alpha exposure by a factor of twenty, which is why internal contamination is treated so seriously.
Mistakes that change the number
- Reading rad as radian: the same three letters mean an angle, and a spreadsheet that mixes them is off by a factor of 57.3.
- Confusing rad with rem: 1 rad is 0.01 Gy, while 1 rem is 0.01 Sv, and they are equal only for gamma and beta radiation.
- Using 1,000 instead of 100 between Gy and rad: an error of ten, and a dose report that reads ten times low.
- Treating mGy and mSv as different for photons: they are numerically identical when the weighting factor is 1.
The radian confusion is more common than it sounds because both symbols appear in imaging software. A CT gantry tilt of 0.1 rad is 5.7 degrees, while a dose of 0.1 rad is 1 mGy. If a report mixes the two, the angular value looks like a dose and the dose looks like an angle, and neither number is wrong in isolation.
Precision and how to quote a dose
All four factors here are exact definitions, so the conversion introduces no error. The uncertainty is in the measurement: a CT dose index is typically quoted to one decimal place in mGy. Reporting 7.000 mGy implies a precision the scanner does not have, and the professionally correct form is 7 mGy, or 0.7 rad if the older unit is required.
Dose and dose rate are different quantities, and both show up in reports. A CT scanner delivers about 7 mGy in 10 seconds, which is 42 mGy per minute, while natural background delivers 2.4 mGy in a year, or roughly 4.6 nGy per minute. The same unit covers both because it is a dose; a rate needs its own time divisor before the two can be compared.
A quick background-dose check
The US average background is about 2.4 mGy per year, mostly from radon and cosmic rays, which is 0.24 rad. A chest CT at 7 mGy equals roughly three years of background, and a full-body PET-CT at 15 mGy is about six. Those comparisons are the ones patients actually understand, and they only work if the mGy figures are converted consistently.
Frequently asked questions
How do I convert Gy to rad?
Multiply by 100. For example, 7 mGy is 0.007 Gy, which is 0.7 rad, and 1 Gy is exactly 100 rad.
How many mGy are in 1 rad?
10 mGy, because 1 rad is 0.01 Gy and 0.01 Gy is 10 mGy. Equivalently 1 mGy is 100 mrad.
What is the difference between Gy and Sv?
Both are joules per kilogram, but the sievert multiplies by a radiation weighting factor. For gamma and beta the factor is 1, so 1 Gy equals 1 Sv; for alpha it is 20, so 1 Gy equals 20 Sv.
How much radiation does a chest CT give?
About 7 mGy, which is 0.7 rad or 700 mrad. That is roughly three years of average US background exposure at 2.4 mGy per year.
How much radiation is dangerous?
Acute radiation syndrome begins around 1 Gy (100 rad) of whole-body dose, and 4 Gy (400 rad) is lethal to about half of untreated people within 60 days.
What is a dental X-ray dose in rad?
A bitewing delivers about 0.005 mGy, which is 0.0005 rad or 0.5 mrad, roughly 1/1,400 of a chest CT.
Is the rad unit still used?
Yes, in older US medical and regulatory documents. The gray has been the SI unit since 1975, and most modern dosimetry reports use mGy while legacy protocols still list rad.
How do I convert kGy to Mrad?
Divide by 10. A 10 kGy food-irradiation dose is 1 Mrad, because 1 Mrad is 10,000 Gy.
Why is 1 rad 0.01 Gy and not 0.001 Gy?
The rad was defined as 100 erg per gram in CGS units. That works out to 0.01 J/kg, so the two systems differ by a factor of 100 rather than a clean power of ten.
Method and sources
- Linear conversion through Gy: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 Milligray (mGy) = 0.001 Gy; 1 Rad (rad) = 0.01 Gy; 1 Millirad (mrad) = 0.00001 Gy.
- The milligray is an exact SI prefix; the rad and millirad are CGS units defined as exactly 0.01 Gy and 10⁻⁵ Gy.
- Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.