CalcSeed

Absorbed Dose Rate Converter

Convert absorbed dose rate between units in real time. Enter a value, choose the from and to units, and read the result instantly.

=
Absorbed Dose Rate Converter — convert between Gy/s, mGy/s, rad/s and more.
Result
—

What this converter returns

Absorbed dose rate is the energy a material absorbs from ionising radiation per unit mass per unit time, measured in gray per second. This page converts between Gy/s, mGy/s and rad/s. At the defaults it turns 1 mGy/s into 0.1 rad/s, which is the same dose rate in the older CGS unit.

The gray is the SI unit and equals one joule per kilogram. The rad is the CGS unit, defined as exactly one hundredth of a gray. Only two conversions exist here, both exact, which makes this one of the few converters where the arithmetic can never be the source of an error.

The conversion rule

dose rate = ΔD ÷ Δt, and result = value × factor(from) ÷ factor(to) with factors 1 Gy/s, 0.001 mGy/s, 0.01 rad/s

Dose rate is absorbed dose divided by the time over which it is delivered. Dose itself is D = ΔE ÷ Δm, energy deposited per unit mass, so 1 Gy means 1 J/kg. Dividing by seconds gives Gy/s, and everything else is a prefix or a definition applied to that base.

The milligray factor is 0.001 because the prefix is a thousandth. The rad factor is 0.01 because the rad was defined in 1953 as 100 ergs per gram, and 100 erg/g works out to 0.01 J/kg. That definition is exact, so 1 Gy equals exactly 100 rad and 1 rad/s equals exactly 0.01 Gy/s.

Dose rate is not dose

A dose of 2 Gy delivered in one minute and the same 2 Gy delivered over an hour are identical as dose and different as rate: 0.033 Gy/s against 0.00056 Gy/s. Biological response depends on both, which is why radiotherapy protocols specify the rate as carefully as the total. The same distinction separates an imaging scan from a chronic exposure of the same total.

Worked example at the defaults

Convert 1 mGy/s to rad/s. The from-factor is 0.001 and the to-factor is 0.01, so 1 × 0.001 ÷ 0.01 = 0.1 rad/s. In millrad it is 100 mrad/s. Going the other way, 1 rad/s is 0.01 Gy/s, or 10 mGy/s.

A radiotherapy linac delivering 2 Gy in one minute runs at 2 ÷ 60 = 0.0333 Gy/s, which is 3.33 rad/s. A CT scan giving 10 mGy in 5 s runs at 2 mGy/s, or 0.2 rad/s. Background at 0.1 µGy/h is 1 × 10−7 Gy ÷ 3,600 s = 2.78 × 10−11 Gy/s, roughly nine orders of magnitude below the linac.

UnitIn Gy/sOne Gy/s equals
Gy/s11 Gy/s
mGy/s0.0011,000 mGy/s
rad/s0.01100 rad/s

Dose rates across applications

The range covered by this converter spans about thirteen decades, from environmental monitoring to flash radiotherapy. The table gives representative values with the arithmetic shown so you can check any of them.

ApplicationTypical rateGy/srad/s
Natural background0.1 µGy/h2.8 × 10−112.8 × 10−9
Chest CT, 10 mGy in 5 s2 mGy/s0.0020.2
Conventional radiotherapy2 Gy/min0.0333.3
Flash radiotherapy40 Gy in 0.1 s40040,000
Sterilisation dose, 25 kGy in 1 h6.9 Gy/s6.9690

The sterilisation row is worth checking: 25,000 Gy over 3,600 s is 6.94 Gy/s, and multiplying by 100 gives 694 rad/s. Industrial irradiators run at that rate for hours, which is why the source is shielded by metres of concrete rather than a lead apron.

Why the rad survives in dosimetry

The rad is deprecated but not gone. Radiation-hardness testing of electronics still quotes total ionising dose in rad, and many detector calibrations are traceable to rad-based standards. Because the conversion is exactly 100, the two unit systems never disagree, so a specification written in rad can be met with a dosimeter read in gray without any rounding risk.

Where the conversion goes wrong

  • Confusing rad with rem. The rad measures absorbed dose, the rem measures equivalent dose after weighting, and 1 rad is not 1 rem for neutrons or alpha particles.
  • Dropping the per-second. A total dose in Gy and a rate in Gy/s differ by the exposure time, and 2 Gy over 60 s is 0.033 Gy/s, not 2 Gy/s.
  • Converting mGy to rad by dividing by 1,000 instead of by 10. One mGy is 0.1 rad, not 0.001 rad.
  • Treating an hourly rate as a per-second rate. 0.1 µGy/h is 2.8 × 10−11 Gy/s, not 0.1 µGy/s.

The hourly-to-second slip is the most common in environmental work. A monitor that logs 0.1 µGy/h and a model that expects Gy/s differ by a factor of 3,600, and a report that mixes them will be wrong by three and a half orders of magnitude.

Common mistakes

  • Assuming dose rate scales linearly with distance without checking whether the source is a point, a line or a plane.
  • Ignoring build-up. The dose in a material rises with depth before it falls, so surface rate is not the rate at the target.
  • Using absorbed dose rate where equivalent dose rate is required, which needs a radiation weighting factor.
  • Rounding 0.1 rad/s to 0.1 Gy/s, a factor-of-ten error that changes a shielding thickness by metres.

Precision and rounding

Both factors are exact definitions, so the only loss is binary floating point at about 1 part in 1016. Dosimetry itself is far looser: a calibrated ion chamber is good to 3 to 5 percent, and film or TLD systems to 10 percent. Report rates to two significant figures, such as 0.033 Gy/s, and keep four only when you are summing many small contributions in a shielding calculation.

Frequently asked questions

How do I convert mGy/s to rad/s?

Divide by 10, or multiply by 0.1. A rate of 1 mGy/s is 0.1 rad/s, and 2 mGy/s is 0.2 rad/s.

How many rad are in one gray?

Exactly 100. The rad is defined as 0.01 Gy, so 1 Gy/s is 100 rad/s and 25 kGy is 2.5 million rad.

Is the rad the same as the rem?

No. The rad is absorbed dose, 0.01 Gy. The rem is equivalent dose, 0.01 Sv, and the two differ by the radiation weighting factor.

What dose rate does radiotherapy use?

A conventional linac delivers about 2 Gy per minute, which is 0.033 Gy/s or 3.3 rad/s. Flash protocols reach 400 Gy/s or 40,000 rad/s.

What is the background dose rate in Gy/s?

About 0.1 µGy/h, which is 2.8 × 10−11 Gy/s or 2.8 × 10−9 rad/s.

Why is the rad factor 0.01?

The rad was defined as 100 ergs per gram, and 100 erg/g equals 0.01 J/kg. That makes 1 rad exactly 0.01 Gy with no rounding.

How many mGy/s are in 1 Gy/s?

1,000. The milli prefix only rescales the gray, so 1 Gy/s is 1,000 mGy/s and 0.001 Gy/s is 1 mGy/s.

Does dose rate matter biologically?

Yes. The same total dose delivered slowly is less damaging, with a dose and dose rate effectiveness factor of about 2 for low-LET radiation at low rates.

Can I convert a total dose with this tool?

Not directly. Enter the total divided by the exposure time in seconds. A 2 Gy fraction in 60 s becomes 0.033 Gy/s before conversion.

How accurate is the result?

The factors are exact definitions, so the arithmetic is perfect. Real dosimetry uncertainty of 3 to 10 percent is what limits any reported rate.

Method and sources

Calculation basis

Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: November 19, 2026
Formula & data sources
  • Linear conversion through Gy/s: result = value × factor(from) ÷ factor(to).
  • Factors applied: 1 mGy/s = 0.001 Gy/s; 1 rad/s = 0.01 Gy/s.
  • The milligray is an exact SI submultiple. The rad is the CGS unit of absorbed dose, defined as exactly 0.01 Gy.
  • Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.

Cite this page

Reference formats
APA 7CalcSeed. (2026, November 19). Absorbed Dose Rate Converter. https://calcseed.com/c/unit/absorbed-dose-rate-converter/
MLA 9"Absorbed Dose Rate Converter." CalcSeed, 19 Nov. 2026, calcseed.com/c/unit/absorbed-dose-rate-converter/.
ChicagoCalcSeed. "Absorbed Dose Rate Converter." Last modified November 19, 2026. https://calcseed.com/c/unit/absorbed-dose-rate-converter/

Related calculators