Permittivity Converter
Convert permittivity between units in real time. Enter a value, choose the from and to units, and read the result instantly.
What permittivity measures
Permittivity describes how much electric flux a material admits for a given field, the ratio of electric displacement to field strength. Its SI unit is the farad per metre (F/m), and the vacuum value is ε₀ = 8.8541878128 × 10⁻¹² F/m, which this converter writes as 8.854 pF/m.
Every material has a relative permittivity that multiplies the vacuum value: 1.0006 for air, 2.1 for PTFE, 4.4 for FR-4 laminate, 11.7 for silicon and about 80 for water. That single multiplier drives cable capacitance, signal velocity and capacitor value.
The conversion rule
The prefixes are nano and pico, so nF/m to pF/m is a factor of 1,000 and pF/m to F/m is 10⁻¹². Both are exact decimal definitions, which means the conversion is a decimal shift and not an approximation.
The vacuum default of 8.854 pF/m is ε₀ rounded to four significant figures. The full value is 8.8541878 pF/m, so a calculation that needs six digits should use the longer form rather than the default.
Worked example: 8.854 pF/m in F/m
The defaults put 8.854 in the pF/m box and target F/m. Multiply by 10⁻¹²: 8.854 × 10⁻¹² F/m, which the four-decimal display rounds to 0.0000.
The rounded display is not a failed conversion. Switch the target to nF/m and the answer appears as 0.008854 nF/m, which keeps the digits. In scientific notation the result is simply 8.854e-12 F/m.
Conversion table
| pF/m | nF/m | F/m |
|---|---|---|
| 1 | 0.001 | 1 × 10⁻¹² |
| 8.854 | 0.008854 | 8.854 × 10⁻¹² |
| 52 | 0.052 | 5.2 × 10⁻¹¹ |
| 1,000 | 1 | 1 × 10⁻⁹ |
| 88,540 | 88.54 | 8.854 × 10⁻⁴ |
The 52 pF/m row is a twisted-pair data cable, which is 16 pF per foot. The 88,540 row is a hundred times vacuum, close to what a high-permittivity ceramic or a wet soil presents.
Where the number is used
Permittivity per metre is the native unit of cable and transmission-line work, where capacitance is distributed along length rather than concentrated in a component.
- Coaxial and twisted-pair cable, where capacitance per metre sets bandwidth and crosstalk.
- PCB transmission lines, where the effective permittivity fixes propagation delay.
- Capacitor dielectric selection, where permittivity times area over thickness gives capacitance.
- Soil moisture and dielectric logging, which infer water content from bulk permittivity.
Capacitance per metre of a coax
A coaxial cable has C = 2πε ÷ ln(b/a) farads per metre. With a solid polyethylene dielectric at εₗ = 2.3, a 1 mm inner conductor and a 3.6 mm shield, ln(b/a) is 1.28 and the capacitance works out near 100 pF/m, which is 0.1 nF/m.
Signal speed follows permittivity
Propagation velocity is c ÷ √εₗ. In vacuum that is 3 × 10⁸ m/s, in polyethylene about 1.98 × 10⁸, and in FR-4 with an effective permittivity of 3.3 about 1.65 × 10⁸ m/s. The practical figure for FR-4 is a delay near 6 ns per metre, or 1.8 ns per foot, which every board designer memorises.
Because delay scales as the square root, halving permittivity only cuts delay by 29 percent. That is why low-permittivity laminates buy bandwidth in modest steps rather than doubling it, and why a 4.4 to 3.3 change moves delay from 6.6 to 5.7 ns/m.
Precision and common mistakes
- Quoting relative permittivity as if it were absolute, which drops the 8.854 × 10⁻¹² factor entirely.
- Reading pF/m as pF: the first is per unit length, the second is a capacitance.
- Using the vacuum value for a cable whose dielectric is polyethylene at 2.3 times higher.
- Entering 8.85 as F/m when the intended value was 8.85 pF/m, an error of 10⁻¹².
From capacitance to permittivity
A parallel-plate capacitor gives permittivity directly: C = εA ÷ d. With 1 m² of plates, a 1 mm gap and polyethylene at εₗ = 2.3, the capacitance is 2.036 × 10⁻¹¹ × 1 ÷ 0.001 = 20.4 nF, so the permittivity is 20.4 nF/m, or 20,400 pF/m.
Halve the gap and the capacitance doubles to 40.8 nF without any change to the material. That is the trap in reading a capacitance value as a material property: geometry and permittivity both enter, and only the per-metre form isolates the dielectric.
Time-domain reflectometry uses the same relation in reverse. A probe sends a pulse down a rod buried in soil and times the echo: t = 2L√εₗ ÷ c. Over a 0.3 m probe the round trip takes 4 ns in dry soil at εₗ = 4 and 10 ns at εₗ = 25, which is wet soil. The delay alone gives the water content.
Permittivity is also frequency dependent, which is why one number rarely describes a material. Water holds a relative permittivity near 80 below 1 GHz and falls to about 5 above 100 GHz as the molecular dipoles stop following the field. A capacitor specified at 1 kHz and a radar absorber specified at 10 GHz are describing different regimes of the same substance.
Datasheets always state a test frequency, and the number drifts with it. Polyester film reads a relative permittivity near 3.3 at 1 kHz and closer to 3.0 at 1 MHz, so a capacitor designed from the low-frequency value will measure a few percent low at radio frequencies. Convert the per-metre value from the same frequency the design uses, not from whichever table is closest to hand.
A quick check
One nanofarad per metre is 1,000 pF/m, and one picofarad per metre is 10⁻¹² F/m. Multiply a pF/m figure by 10⁻¹² to reach SI, or shift the decimal twelve places left. For a 100 pF/m cable, 10 m of length holds 1,000 pF, which is 1 nF.
Frequently asked questions
What is the permittivity of free space?
8.8541878128 × 10⁻¹² F/m, which is 8.854 pF/m to four significant figures. This converter’s default is that rounded value.
How many pF/m is 1 nF/m?
1,000 pF/m. Nano is 10⁻⁹ and pico is 10⁻¹², so the ratio is exactly 1,000.
How many F/m is 100 pF/m?
1 × 10⁻⁴ F/m. Multiply 100 by 10⁻¹², or shift the decimal twelve places: 100 pF/m = 0.000000000100 F/m.
What is the permittivity of FR-4?
About 3.9 × 10⁻¹¹ F/m for εₗ = 4.4, which is 39 pF/m. The effective value in a microstrip is lower, near 3.3, because part of the field travels in air.
How do I convert relative permittivity to F/m?
Multiply by ε₀ = 8.854 × 10⁻¹². Water at 80 becomes 7.08 × 10⁻⁵ F/m, and air at 1.0006 becomes 8.859 pF/m.
Why does the result show 0.0000?
The display keeps four decimals, and 8.854 × 10⁻¹² is far below that threshold. Convert to nF/m to see 0.008854, or read the scientific-notation figure.
What is the capacitance of 10 m of 100 pF/m cable?
1,000 pF, or 1 nF. Capacitance adds with length, so 100 m of the same cable is 10 nF.
How does permittivity affect signal speed?
Velocity is c ÷ √εₗ. At εₗ = 4.4 the speed is 0.48c, and at 3.3 it is 0.55c, giving delays of 7.0 and 6.1 ns/m.
Is permittivity the same as conductivity?
No. Permittivity stores electric energy, conductivity dissipates it. A material can have a high permittivity and negligible conductivity, as dry soil does, or both high, as seawater does.
Method and sources
- Linear conversion through F/m: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 nF/m = 1 × 10⁻⁹ F/m; 1 pF/m = 1 × 10⁻¹² F/m.
- Every factor is an exact decimal SI prefix of the base unit, so no rounded constant is involved.
- Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.