Irradiance Converter
Convert irradiance between units in real time. Enter a value, choose the from and to units, and read the result instantly.
What irradiance is
Irradiance is power arriving per unit area, measured in watts per square metre. It is the number that describes sunlight, a laser spot, a UV lamp or the light inside a growth chamber, and it is the input to every solar panel yield calculation. At the defaults, 1,000 W/m² — one standard sun — converts to 100 mW/cm².
Four units cover the field: W/m² and kW/m² for solar and architectural work, mW/cm² for sensors and curing, and W/cm² for lasers. The conversion is one factor ratio: result = value × factor(from) ÷ factor(to).
Why mW/cm² is exactly 10 W/m²
A square centimetre is 1e-4 m², so the same power concentrated on a cm² is 10,000 times the density per m². A milliwatt is 1e-3 W. Dividing 1e-3 by 1e-4 gives 10, so 1 mW/cm² = 10 W/m² and 1 W/cm² = 10,000 W/m². Both factors are exact, which is why a 1,000 W/m² standard test condition converts to a clean 100 mW/cm².
Irradiance versus irradiation
Irradiance is a rate, W/m²; irradiation is energy per area, kWh/m² or MJ/m². Multiply irradiance by time to get irradiation: 1,000 W/m² for 5 hours is 5 kWh/m², which solar designers call five peak sun hours. A day with 5 kWh/m² of irradiation is a good summer day in most of the US, and a winter day in the north can fall to 1–2 kWh/m².
Worked example at the default settings
Convert 1,000 W/m² to mW/cm²: 1,000 × 1 ÷ 10 = 100 mW/cm². The same value is 1 kW/m² and 0.1 W/cm². All four describe standard test conditions for photovoltaics: 1,000 W/m², 25 °C cell temperature and an AM1.5 spectrum.
Now size a panel output. A 400 W module with an area of 1.95 m² receives 1,000 × 1.95 = 1,950 W at standard conditions, so its efficiency is 400 ÷ 1,950 = 20.5%. At a realistic 800 W/m² it produces about 320 W, and at 200 W/m² under heavy cloud, 80 W — the ratio holds because module current scales almost linearly with irradiance.
Common irradiance levels
| Situation | W/m² | mW/cm² | kW/m² |
|---|---|---|---|
| Direct sunlight (clear noon) | 1,000 | 100 | 1.0 |
| Solar constant at top of atmosphere | 1,361 | 136.1 | 1.361 |
| Overcast day | 100–200 | 10–20 | 0.1–0.2 |
| UV index 1 (erythemal) | 0.025 | 0.0025 | 0.000025 |
| Laser curing spot | 10,000 | 1,000 | 10 |
| Industrial UV curing | 50,000 | 5,000 | 50 |
The UV row explains the UV index: one index unit corresponds to 25 mW/m² of erythemal-weighted irradiance, so a UV index of 8 is 200 mW/m², or 0.02 mW/cm². That is four orders of magnitude below sunlight in total power, which is why UV damage is about spectrum rather than raw irradiance.
Where each unit is used
- Photovoltaics: W/m² for yield modelling, with 1,000 W/m² at STC and performance ratio computed against kWh/m² of irradiation.
- Sensors and optoelectronics: mW/cm² for photodiode responsivity, where 1 mW/cm² at 850 nm on a 1 mm² silicon detector produces roughly 5 µA.
- Laser and LED curing: W/cm² for dose, and 1 W/cm² for 10 s is 10 J/cm², a typical adhesive cure.
- Agriculture and horticulture: PPFD in µmol/m²/s rather than W/m², since plants respond to photon count, not energy; 1,000 W/m² of sunlight is about 2,000 µmol/m²/s.
Reading a module curve at other irradiances
Module current scales almost exactly with irradiance, so at 500 W/m² a panel rated 10 A at standard conditions delivers about 5 A. Voltage falls only slightly, from around 34 V to 32 V on a typical 60-cell module, so power drops a little faster than the irradiance ratio alone suggests: a 400 W panel at 800 W/m² delivers about 315 W, just under the 320 W that a strictly linear model would predict.
Why solar work still quotes 1,000 W/m²
The 1,000 W/m² standard is not the maximum. The solar constant at the top of the atmosphere is 1,361 W/m², and a clear noon at high altitude can exceed 1,100 W/m² at the surface. The lower figure is a convention that lets manufacturers compare panels, and it happens to sit near the typical peak at sea level with the sun overhead. Measured output above 1,000 W/m² is normal on cold, clear days, and it is one reason inverters are rated with a DC input margin.
Concentration photovoltaics and solar thermal deliberately exceed the standard: a 500-sun system runs at 500,000 W/m², or 50 W/cm². Converting that to W/cm² is a factor of 10,000, so the same concentration quoted as 50 W/cm² and 5 MW/m² describes one receiver, and unit errors at that scale destroy hardware in seconds.
Precision and measurement
All four factors are exact powers of ten, so the arithmetic carries no error. Measurement does: a calibrated pyranometer is good to ±2–5%, and a cheap lux meter converted to W/m² can be out by 30% because lux is weighted for human vision, not for power. Calibration certificates state the uncertainty in W/m², and no conversion can improve on it.
Mistakes worth avoiding
- Reading 1,000 W/m² as 1,000 mW/cm². The correct figure is 100 mW/cm², a tenfold difference.
- Multiplying by 10,000 when going from mW/cm² to W/m². The factor is 100, since 100 mW/cm² is 1,000 W/m².
- Confusing irradiance with irradiation: 1,000 W/m² is a rate, and it becomes 5 kWh/m² only after five hours.
- Comparing a lux reading with a W/m² specification, which mixes a photometric unit with a radiometric one.
Frequently asked questions
How many mW/cm² is 1,000 W/m²?
100 mW/cm², which is standard test conditions for solar panels. The factor is 10 W/m² per mW/cm².
How do I convert mW/cm² to W/m²?
Multiply by 10. A 50 mW/cm² lamp is 500 W/m², and 100 mW/cm² is 1,000 W/m².
What is 1 sun in W/m²?
1,000 W/m², or 100 mW/cm², or 1 kW/m². It is a testing convention, not the maximum, since the solar constant is 1,361 W/m².
How many W/m² is 1 W/cm²?
10,000 W/m². A 1 W/cm² laser spot is 10 kW/m², roughly seven times the solar constant of 1,361 W/m².
Is irradiance the same as solar irradiation?
No. Irradiance is instantaneous power per area in W/m²; irradiation is energy per area in kWh/m². Five hours at 1,000 W/m² gives 5 kWh/m².
How do I calculate a solar panel output from irradiance?
Multiply irradiance by area and by efficiency. A 400 W panel of 1.95 m² at 1,000 W/m² receives 1,950 W and converts at 20.5%.
What irradiance does a UV index of 5 represent?
About 125 mW/m² of erythemal-weighted UV, since one index unit is 25 mW/m². That is 0.0125 mW/cm².
How bright is a cloudy day in W/m²?
Roughly 100–200 W/m², which is 10–20 mW/cm². Panels still produce 10–20% of their rated output under that light.
Why is 1,000 W/m² used for panel ratings?
It is a round, reproducible reference close to sea-level peak sun, agreed so that a 400 W panel means the same thing in every market. Real sites vary from 100 to 1,100 W/m².
Method and sources
- Linear conversion through W/m²: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 mW/cm² = 10 W/m²; 1 kW/m² = 1000 W/m²; 1 W/cm² = 10000 W/m².
- Every factor is an exact decimal SI prefix of the base unit, so no rounded constant is involved.
- Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.