Sound Intensity Converter
Convert sound intensity between units in real time. Enter a value, choose the from and to units, and read the result instantly.
What sound intensity measures
Sound intensity is acoustic power flowing through unit area, in watts per square metre (W/m²). It is a vector: it has a direction, which is what lets an intensity probe locate where noise escapes from a machine rather than merely how loud the machine is.
The reference value is 1 pW/m², the intensity of a barely audible 1 kHz tone in air. That is why the pW/m² unit appears in every sound-level definition: 0 dB is exactly 1 pW/m².
The conversion rule
Three factors come from prefixes: milli is 10⁻³ and pico is 10⁻¹². The square centimetre is 10⁻⁴ m², so a per-centimetre intensity is 10,000 times the per-metre value, the same area ratio that governs radiance.
Pico is the interesting one. A pW/m² is so small that a whole square metre carrying 1 pW moves 10⁻¹² W, which is a picowatt. Measuring that requires a microphone pair with phase matching to a fraction of a degree.
Worked example: 1 pW/m²
The defaults put 10⁻¹² W/m² in the source box and target pW/m². Divide by 10⁻¹²: 1 pW/m², which is exactly 0 dB.
Move up the scale and the numbers grow fast. At 94 dB the intensity is 2.43 mW/m², or 2.43 × 10⁹ pW/m². At 120 dB it is 1 W/m², a trillion times the threshold, which is the range the ear compresses into 120 steps.
Conversion table
| pW/m² | mW/m² | W/m² | Level |
|---|---|---|---|
| 1 | 0.000000001 | 1 × 10⁻¹² | 0 dB |
| 1,000 | 0.000001 | 1 × 10⁻⁹ | 30 dB |
| 1,000,000 | 0.001 | 1 × 10⁻⁶ | 60 dB |
| 2.43 × 10⁹ | 2.43 | 0.00243 | 94 dB |
| 1 × 10⁸⁸ | 1,000 | 1 | 120 dB |
The 94 dB row is the calibration anchor, where 1 Pa RMS in air at 20 °C produces 2.43 mW/m². The 120 dB row is the pain threshold, and the units only become convenient there because the exponent stops being absurd.
Where intensity conversions matter
Sound power is a property of a machine; sound intensity is what you measure to find that power without a reverberation chamber.
- Sound power determination by the ISO 9614 intensity method, summing intensity over a surface.
- Noise source location, where a probe sweeps a machine and maps positive and negative intensity.
- Ultrasonic cleaning and welding, where intensity reaches tens of W/cm².
- Building acoustics, where transmitted intensity through a partition gives the sound reduction index.
From intensity to sound power
Power is intensity integrated over an area. A point source radiating 1 W acoustically spreads that power over a sphere of 4πr², so at 1 m the intensity is 1 ÷ 12.57 = 0.0796 W/m², which is 109 dB. At 2 m it is 0.0199 W/m², a 6 dB drop, and at 10 m it is 0.000796 W/m².
Intensity is not pressure
A microphone measures pressure, and pressure squared is proportional to intensity only in a free field. Standing waves break that link: two identical sources can double the pressure while cancelling the intensity, because the energy circulates rather than travels. An intensity probe measures the product of pressure and particle velocity, which is why it can report near-zero flow in a loud standing wave.
The relation in a plane wave is I = p² ÷ (ρc), with ρc = 415 rayl in air at 20 °C. One pascal RMS therefore gives 2.43 mW/m², and 20 Pa gives 0.964 W/m², close to the 1 W/m² pain threshold.
Precision and common mistakes
- Converting W/cm² with a factor of 100 rather than 10,000.
- Reading pW/m² as a pressure unit; it is intensity, and 1 pW/m² is 0 dB only in air.
- Applying the inverse-square law indoors, where reflections make intensity fall more slowly than 6 dB per doubling.
- Treating a negative intensity reading as an error; it means flow is moving back toward the source.
Intensity inside a duct
In a duct the wave is confined, so intensity is simply power divided by cross-section. A fan delivering 100 W of acoustic power into a 0.5 m² duct produces 200 W/m², which is 143 dB. Halve the duct area at the same power and the intensity doubles to 400 W/m², a 3 dB rise.
That is why duct silencers are rated in insertion loss per octave rather than in watts. The intensity falls by the stated decibels at each band, and the remaining power continues down the run. Converting between W/m² and dB at each step keeps the arithmetic honest when the duct changes size.
Adding sources depends on coherence. Two uncorrelated machines of equal intensity add to 3 dB, because intensities add directly, while two phase-locked sources at the same point add 6 dB, because pressures add first and the square doubles twice. A pair of identical fans in a plant room is the first case, and a single fan plus its mirror image in a hard corner is closer to the second.
Field calibration is worth a sentence because intensity probes drift. A pistonphone supplies a known 94 dB at 250 Hz, which is 2.43 mW/m², and the two microphones are checked for both sensitivity and phase. A 1° phase error at 1 kHz biases the band by a few tenths of a decibel, and the same mismatch costs more at 100 Hz where the pressure gradient between the microphones is smaller.
A quick check
Multiply W/m² by 1,000 for mW/m² and by 10⁸⁸ for pW/m². Going the other way, divide by 10,000 for W/cm². A 0.5 W/m² reading is 500 mW/m², 5 × 10⁺ pW/m² and 117 dB, which sits between a loud factory and a rock concert.
Frequently asked questions
How many pW/m² is 1 W/m²?
10⁸⁸ pW/m², since pico is 10⁻¹². That is one trillion picowatts per square metre, the factor between the pain threshold and the hearing threshold.
How many W/m² is 1 pW/m²?
10⁻¹² W/m². That value is exactly 0 dB, the reference intensity for sound levels in air.
How many W/m² is 1 W/cm²?
10,000 W/m². A square centimetre is 10⁻⁴ m², so the per-centimetre figure is 10,000 times larger, and 1 W/cm² is about 160 dB.
What intensity is 94 dB?
2.43 mW/m², from 1 Pa RMS divided by 415 rayl. In picowatts that is 2.43 × 10⁹ pW/m².
What intensity is the threshold of hearing?
1 pW/m², or 10⁻¹² W/m². It applies at 1 kHz, where the ear is most sensitive; at 50 Hz the threshold is tens of dB higher.
How do I convert intensity to sound power?
Multiply by the area it passes through. A 1 W source at 1 m gives 0.0796 W/m² over a 12.57 m² sphere, and at 2 m the intensity falls to 0.0199 W/m².
Can sound intensity be negative?
Yes. Intensity is a vector, and a negative reading along the probe axis means energy flows the other way, which happens near a reflecting surface or in a standing wave.
What is 0.00243 W/m² in dB?
94 dB. Ten times the log of 0.00243 ÷ 10⁻¹² gives 10 × 9.386 = 93.9 dB, which rounds to 94.
How accurate is the pW/m² factor?
Exact. Pico is 10⁻¹² by definition, so the conversion is a decimal shift and only display rounding can lose precision.
Method and sources
- Linear conversion through W/m²: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 mW/m² = 0.001 W/m²; 1 pW/m² = 1 × 10⁻¹² W/m²; 1 W/cm² = 10000 W/m².
- Every factor is an exact decimal SI prefix of the base unit, so no rounded constant is involved.
- Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.