CalcSeed

Electrical Conductance Converter

Convert electrical conductance between units in real time. Enter a value, choose the from and to units, and read the result instantly.

=
Electrical Conductance Converter — convert between Siemens (S), Millisiemens (mS), Kilosiemens (kS) and more.
Result
—

What a siemens measures

Electrical conductance is how easily a component lets current through, and the siemens is one ampere per volt — the exact reciprocal of the ohm. This converter moves between siemens, millisiemens, kilosiemens and microsiemens. At the defaults it turns 1 S into 1,000 mS, which is the same thing as saying a one-ohm resistor conducts one siemens.

The conversion formula

result = value × factorfrom ÷ factorto  ·  G = 1 ÷ R  ·  1 mS = 0.001 S  ·  1 kS = 1,000 S  ·  1 µS = 0.000001 S

The siemens is defined through the ampere and the volt, so it needs no measured constant. Milli, kilo and micro are powers of ten, which makes every conversion in this tool a decimal shift. The only formula that matters beyond the prefix is the reciprocal: conductance is one divided by resistance, so a 4.7 kΩ resistor is 213 µS.

The unit was once called the mho, ohm spelled backwards, and its symbol was an inverted omega. You will still see mho in older American texts and in some relay settings, but the siemens has been the SI name since 1971 and the two are identical in size.

Worked example: 1 siemens

At the defaults the value is 1 and the units run from S to mS: 1 × 1 ÷ 0.001 = 1,000 mS. That conductance corresponds to a 1 Ω resistance, which at 1 V carries exactly 1 A.

Move along the scale to see how the numbers behave. A 1 kΩ resistor is 1 mS, a 10 kΩ resistor is 0.1 mS or 100 µS, and a 10 MΩ insulation path is 0.1 µS. Conductance compresses large resistances into small numbers, which is convenient for leakage and insulation work but awkward for ordinary circuit design.

Conductance conversions at a glance

FromTo unitMultiply by
1 SmS1,000
1 SµS1,000,000
1 SkS0.001
1 mSS0.001
1 mSµS1,000
1 µSS0.000001
1 kSS1,000

Two anchors are enough for bench work. A millisiemens is a thousand microsiemens, so 2.5 mS is 2,500 µS; a kilosiemen is a thousand siemens, and values that large appear only in power electronics and electrochemistry, where a cell might run at several kS.

Conductance in real devices and solutions

ItemConductanceEquivalent resistance
Wire shortabout 100 S10 mΩ
1 kΩ resistor1 mS1 kΩ
10 kΩ resistor100 µS10 kΩ
Dry skin path1–10 µS0.1–1 MΩ
Insulation at 1 MΩ1 µS1 MΩ
Seawater cellabout 5 S0.2 Ω

The seawater row is a reminder that conductance is not only an electronics quantity. A conductivity cell with 1 cm² plates 1 cm apart holding seawater reads about 5 S, because seawater conductivity is roughly 5 S/m. The same cell in drinking water reads 20 to 80 mS, and in ultrapure water it reads 0.055 µS.

Where the conversion bites in practice

  • Conductivity meters report S/cm, not S. A reading of 1,000 µS/cm is 0.1 S/m, because the centimetre in the denominator is 100 times smaller than a metre.
  • Conductances add in parallel while resistances add in series, so a parallel pair of 10 kΩ resistors is 200 µS, not 100 and not 50.
  • Electroplating and battery electrolyte specs use S/m, while water-treatment instruments use µS/cm. The two differ by a factor of 100, and a 500 µS/cm mains reading is 5 mS/m.
  • Leakage current in a capacitor is often specified as an insulation resistance in MΩ, which is a conductance in µS; a 100 MΩ part leaks 10 nA at 1 V.

The distinction that causes the most confusion is conductance against conductivity. Conductance is a property of a particular object and is measured in siemens; conductivity is a property of the material and is measured in siemens per metre. A short fat wire and a long thin one of the same copper have very different conductances and identical conductivity.

Common mistakes

Forgetting the reciprocal

It is tempting to treat siemens like a scaled ohm and multiply where you should divide. A 250 Ω resistor is 4 mS, not 250,000. Whenever you cross between the two quantities, write the reciprocal explicitly: G = 1/R, so R = 1/G. A 0.5 S device is 2 Ω, and a 2 S device is 0.5 Ω.

Microsiemens are not megohms

1 µS equals 1 MΩ, because both are the reciprocal pair of the same decade. That coincidence makes water-quality and insulation work easy once you see it: 0.1 µS/cm water is 10 MΩ·cm water, and a 10 MΩ insulation tester is reading 0.1 µS of leakage. Mixing up the direction turns a pass into a fail.

A second trap is the temperature coefficient. Electrolytic conductivity rises about 2 percent per °C, so a cell calibrated at 25 °C reads roughly 20 percent higher at 35 °C. Meters compensate automatically, but only if the temperature sensor is connected and the compensation is set to the right standard.

  • G = 1/R always: 250 Ω is 4 mS and 4 mS is 250 Ω, so multiplying instead of dividing squares the error.
  • 1 µS equals 1 MΩ, which is why 0.1 µS/cm water is 10 MΩ·cm water and a 100 MΩ part leaks 10 nA at 1 V.
  • Electrolytic conductivity rises about 2 percent per °C, so a cell calibrated at 25 °C reads 20 percent high at 35 °C without compensation.

Precision and rounding

All four factors are exact, so the converter is not the limiting factor. Real measurements are: a handheld conductivity meter is good to 1 to 2 percent of reading, and a bench meter to about 0.5 percent. Report two or three significant figures and stop.

At the low end the numbers get awkward. A 0.055 µS/cm ultrapure water reading is 5.5 × 10-5 mS/cm, and the converter keeps enough decimals to show it, but the practical floor for a cheap meter is around 1 µS. Below that you are measuring the cell, not the water.

Frequently asked questions

How many millisiemens are in 1 siemens?

Exactly 1,000. A one-ohm resistor conducts 1 S, a 1 kΩ resistor conducts 1 mS, and a 1 MΩ resistor conducts 1 µS, so each decade of resistance is a decade of conductance.

How do I convert siemens to ohms?

Take the reciprocal: R = 1/G. A conductance of 4 mS is 1 ÷ 0.004 = 250 Ω, and 0.5 S is 2 Ω. The units are exact inverses, not a scale factor.

Is a mho the same as a siemens?

Yes, identical in size. The mho was the older name, chosen because it is ohm spelled backwards, and it survives in legacy relay and cable documents. One mho is one siemens.

How many microsiemens is 1 millisiemens?

1,000. A 2.5 mS conductance is 2,500 µS, and 0.05 mS is 50 µS. Microsiemens is the working unit for water purity and leakage measurements.

What is the conductance of pure water?

About 0.055 µS/cm of conductivity, which for a standard 1 cm cell is 0.055 µS of conductance. That is roughly 18 MΩ·cm resistivity, the specification quoted for ultrapure water.

Why is seawater around 5 siemens?

Seawater conductivity is about 5 S/m, so a cell with plates 1 cm apart and 1 cm² in area reads roughly 5 S. That is why marine corrosion happens fast: the water itself is a low-resistance path.

Does conductance add in parallel?

Yes, conductances add in parallel because currents add. Two 10 kΩ resistors in parallel give 200 µS, while their resistances combine to 5 kΩ. Resistances add in series and conductances add in parallel.

What is the difference between conductance and conductivity?

Conductance is a property of an object and is measured in siemens; conductivity is a property of a material and is measured in siemens per metre. Dividing conductance by the cell constant in metres gives conductivity.

How much leakage is 1 microsiemens at 5 volts?

5 µA, from I = V × G. That is why 1 µS is the same as 1 MΩ: at 5 V a 1 MΩ path also passes 5 µA.

Method and sources

Calculation basis

Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: November 19, 2026
Formula & data sources
  • Linear conversion through S: result = value × factor(from) ÷ factor(to).
  • Factors applied: 1 Millisiemens (mS) = 0.001 S; 1 Kilosiemens (kS) = 1000 S; 1 Microsiemens (µS) = 0.000001 S.
  • Every factor is an exact decimal SI prefix of the base unit, so no rounded constant is involved.
  • Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.

Cite this page

Reference formats
APA 7CalcSeed. (2026, November 19). Electrical Conductance Converter. https://calcseed.com/c/unit/electrical-conductance-converter/
MLA 9"Electrical Conductance Converter." CalcSeed, 19 Nov. 2026, calcseed.com/c/unit/electrical-conductance-converter/.
ChicagoCalcSeed. "Electrical Conductance Converter." Last modified November 19, 2026. https://calcseed.com/c/unit/electrical-conductance-converter/

Related calculators