CalcSeed

Electric Resistivity Converter

Convert electric resistivity between units in real time. Enter a value, choose the from and to units, and read the result instantly.

=
Electric Resistivity Converter — convert between Ω·m, Ω·cm, µΩ·m and more.
Result
—

What resistivity measures

Resistivity is the resistance of a material itself, normalised to a one-metre cube, so it is quoted in ohm-metres. Resistance depends on the object; resistivity does not. This converter switches between ohm-metres, ohm-centimetres and microhm-metres. At the defaults it turns 0.01 Ω·m into 1 Ω·cm, which is the sort of figure you meet in soil and water surveys.

The conversion formula

result = value × factorfrom ÷ factorto  ·  ρ = R × A ÷ L  ·  1 Ω·cm = 0.01 Ω·m  ·  1 µΩ·m = 0.000001 Ω·m

The ohm-metre is the coherent SI unit. The ohm-centimetre comes from CGS practice: a centimetre is 0.01 m long and a square centimetre is 10-4 m², so the ratio of length to area changes by 0.01 ÷ 10-4 = 100. That is why 1 Ω·cm is 0.01 Ω·m, a factor of one hundred rather than a thousand.

The microhm-metre is a pure prefix: 10-6 Ω·m. Metals sit in that range, so copper at 1.68 × 10-8 Ω·m is 0.0168 µΩ·m. Handbooks sometimes quote 1.68 µΩ·cm, which is the same material described in a smaller unit still.

Worked example: 0.01 ohm-metres

At the defaults the value is 0.01 and the units run from Ω·m to Ω·cm: 0.01 × 1 ÷ 0.01 = 1 Ω·cm. Read that as a soil sample or a brackish water layer, where conduction happens through dissolved ions rather than through a metal lattice.

Convert the same value to microhm-metres: 0.01 ÷ 0.000001 = 10,000 µΩ·m. The number is large because the unit is tiny; nothing about the material changed. This is why engineers pick a unit matched to the decade they work in and stay there.

Resistivity conversions at a glance

FromTo unitMultiply by
1 Ω·mΩ·cm100
1 Ω·mµΩ·m1,000,000
1 Ω·cmΩ·m0.01
1 Ω·cmµΩ·m10,000
1 µΩ·mΩ·m0.000001
1 µΩ·mΩ·cm0.0001
1.68 × 10-8 Ω·mµΩ·m0.0168

The hundred-fold step is the one to internalise. Copper at 1.68 × 10-8 Ω·m is 1.68 × 10-6 Ω·cm, not 1.68 × 10-5. Anyone who has compared a US wire table in ohm-circular-mil-per-foot with a metric table in ohm-square-millimetre-per-metre has met this factor from the other side.

Resistivity of real materials

MaterialΩ·mΩ·cm
Copper1.68 × 10-81.68 × 10-6
Aluminium2.65 × 10-82.65 × 10-6
Nichrome1.10 × 10-61.10 × 10-4
Seawaterabout 0.220
Drinking water10–1001,000–10,000
Ultrapure water1.82 × 1051.82 × 107
PTFEabout 10231025

The range is twenty-nine orders of magnitude, which is why no single unit serves every case. Copper and aluminium differ by 58 percent, which is exactly why aluminium transmission cable needs a larger cross-section for the same current. Nichrome, at 1.1 × 10-6 Ω·m, is sixty-five times more resistive than copper, and that is the point of a heating element.

Where the conversion bites in practice

  • Water purification quotes 18.2 MΩ·cm, which is 182,000 Ω·m. Converting with a division by 1,000 instead of 100 costs a decade, and it is the usual slip.
  • Cable sizing uses resistivity directly: R = ρL/A. A 100 m run of 2.5 mm² copper is 1.68 × 10-8 × 100 ÷ 2.5 × 10-6 = 0.67 Ω, which at 16 A drops 10.7 V.
  • Semiconductor data is quoted in Ω·cm because wafer dimensions are in centimetres. Intrinsic silicon near 2.3 × 105 Ω·cm is 2,300 Ω·m, and doped wafers drop to 0.01–10 Ω·cm.
  • Soil resistivity surveys report Ω·m and drive earthing design: 100 Ω·m soil gives a rod resistance near 30 Ω, while 1,000 Ω·m rock gives about 300 Ω for the same rod.

Note how often the arithmetic is R = ρL/A rather than a unit conversion. Resistivity converters are usually a step inside a bigger calculation, so the value has to land in the unit the rest of the formula expects: metres with square metres, centimetres with square centimetres, never mixed.

Common mistakes

Resistivity is not resistance

A copper busbar and a copper wire can both measure 1 mΩ while sharing a resistivity of 1.68 × 10-8 Ω·m. Resistance scales with length and inversely with area; resistivity does not scale at all. If your number changes when you cut the sample in half, it was resistance.

The hundred-fold trap

Because 1 Ω·cm is 0.01 Ω·m, converting the wrong way costs exactly two decades. A 500 Ω·cm reading is 5 Ω·m, not 50 and not 0.5. Write the factor as 100 Ω·cm per Ω·m and check the direction against something you know, such as copper at 1.68 microhm-centimetres.

Temperature is the other silent variable. Copper resistivity rises about 0.39 percent per °C, so a winding measured at 20 °C and again at 75 °C differs by 21 percent. Reference tables are quoted at 20 °C, and comparing a hot measurement to a cold table without correction is a routine source of apparent faults.

  • 100 Ω·cm is 1 Ω·m, so this conversion moves two decades, not three.
  • Copper at 1.68 × 10-8 Ω·m is 1.68 microhm-centimetres, and a slip of 100 makes a metal look like a resistor.
  • Copper resistivity rises 0.39 percent per °C, so a winding at 75 °C measures 21 percent above its 20 °C value.

Precision and rounding

All factors here are exact decimals, so the converter adds nothing. Real uncertainty comes from the sample: alloy composition moves copper from 1.68 to 1.72 × 10-8 Ω·m, and annealing changes it again. Two significant figures is honest for most metals, three for a certified reference.

Very large values lose meaning on the display. PTFE at 1023 Ω·m is beyond any meter and beyond most published ranges; treat insulators as greater than 1014 unless you have a specific test standard and a guarded fixture.

Frequently asked questions

How many ohm-centimetres are in 1 ohm-metre?

Exactly 100. A centimetre is 0.01 m and a square centimetre is 10-4 m², so the length-to-area ratio changes by 100. Copper at 1.68 × 10-8 Ω·m is 1.68 × 10-6 Ω·cm.

What is the resistivity of copper?

About 1.68 × 10-8 Ω·m at 20 °C, which is 0.0168 µΩ·m or 1.68 microhm-centimetres. Aluminium is 2.65 × 10-8 Ω·m, about 58 percent higher.

How do I convert 18.2 M ohm-cm to ohm-metres?

Multiply by 0.01: 18.2 MΩ·cm is 182,000 Ω·m. That is ultrapure water at 25 °C, the specification used for laboratory reagent water.

Is resistivity the same as resistance?

No. Resistance in ohms depends on the size and shape of the object; resistivity in ohm-metres is a material property. They are linked by R = ρL/A, so a long thin wire and a short thick bar can share a resistance but not a resistivity.

What is 1 microhm-metre in ohm-metres?

0.000001 Ω·m. The micro prefix is 10-6, and the unit is used for metals: copper at 1.68 × 10-8 Ω·m is 0.0168 µΩ·m.

Why is seawater so conductive?

Dissolved salts provide mobile ions, giving a resistivity near 0.2 Ω·m, about a hundred times lower than drinking water at 20 Ω·m. That is why marine structures need cathodic protection.

Does temperature change resistivity?

Yes, for metals it rises about 0.4 percent per °C: copper goes from 1.68 to 2.03 × 10-8 Ω·m between 20 and 75 °C. Semiconductors move the other way, falling as they warm.

How do I get resistance from resistivity?

Multiply by length and divide by cross-sectional area, keeping both in the same length unit as the resistivity. A 100 m copper run of 2.5 mm² comes to 0.67 Ω.

What resistivity is used for earthing design?

Soil surveys typically report 10 to 1,000 Ω·m. Moist clay near 10 Ω·m needs a short rod, while dry sand or rock above 500 Ω·m needs a grid or chemical electrodes.

Method and sources

Calculation basis

Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: November 19, 2026
Formula & data sources
  • Linear conversion through Ω·m: result = value × factor(from) ÷ factor(to).
  • Factors applied: 1 Ω·cm = 0.01 Ω·m; 1 µΩ·m = 0.000001 Ω·m.
  • Every factor is an exact decimal SI prefix of the base unit, so no rounded constant is involved.
  • Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.

Cite this page

Reference formats
APA 7CalcSeed. (2026, November 19). Electric Resistivity Converter. https://calcseed.com/c/unit/electric-resistivity-converter/
MLA 9"Electric Resistivity Converter." CalcSeed, 19 Nov. 2026, calcseed.com/c/unit/electric-resistivity-converter/.
ChicagoCalcSeed. "Electric Resistivity Converter." Last modified November 19, 2026. https://calcseed.com/c/unit/electric-resistivity-converter/

Related calculators