Electric Field Strength Converter

Convert electric field strength between units in real time. Enter a value, choose the from and to units, and read the result instantly.

=
Electric Field Strength Converter — convert between V/m, kV/m, N/C and more.
Result
—

What electric field strength measures

Electric field strength is the force a unit charge would feel at a point, and the SI unit is volts per metre. It is also newtons per coulomb, which is the same thing written from the force side. This converter handles V/m, kV/m, N/C and kV/cm. At the defaults it turns 1,000 V/m into 1 kV/m, the field between two plates a millimetre apart at one volt.

The conversion formula

result = value × factorfrom ÷ factorto  ·  1 kV/m = 1,000 V/m  ·  1 N/C = 1 V/m  ·  1 kV/cm = 100,000 V/m

Volts per metre is the coherent form: a field of 1 V/m exerts 1 V of potential difference across each metre, so the unit follows directly from the definition of the volt. The kilovolt prefix is an exact thousand, and the kilovolt per centimetre combines that with a hundred, giving 100,000 V/m.

Newtons per coulomb is not a different quantity. Since one volt is one joule per coulomb and one joule is one newton-metre, a volt per metre is a newton-metre per coulomb per metre, and the metres cancel. The two units are interchangeable at exactly 1:1, which is why dielectric-strength tables mix them without comment.

Worked example: 1,000 V/m

At the defaults the value is 1,000 and the units run from V/m to kV/m: 1,000 × 1 ÷ 1,000 = 1 kV/m. Physically that is the field between two plates 10 mm apart with 10 V across them, or 1 mm apart with 1 V across them.

The same field written in the other two units is 1,000 N/C and 0.01 kV/cm. The kV/cm figure looks small because a centimetre is a large fraction of a metre for this purpose, and it is the unit high-voltage engineers use because insulation thickness is quoted in centimetres or millimetres.

Electric field conversions at a glance

FromTo unitMultiply by
1 V/mkV/m0.001
1 V/mN/C1
1 V/mkV/cm0.00001
1 kV/mV/m1,000
1 kV/mkV/cm0.01
1 kV/cmV/m100,000
1 kV/cmkV/m100

The kV/m to kV/cm row is the one that catches people out: 1 kV/cm is 100 kV/m, not 10. A dielectric test at 3 kV/mm is 3,000 kV/m and 30 kV/cm, and all three describe the same stress on the same insulation.

Fields you meet in the world

SituationV/mkV/cm
Fair-weather atmospheric field1200.0012
Under a 400 kV line at groundabout 5,0000.05
Inside a 10 kV/mm capacitor10,000,000100
Air breakdown at sea level3,000,00030
CRT anode surface>107>100
Laser-induced plasma109107

Air breakdown is the number worth remembering: about 3 MV/m at sea level, which is 30 kV/cm. Every high-voltage design is an argument about staying below that figure with margin, since humidity, surface contamination and electrode shape all lower it. At altitude the breakdown field falls roughly 10 percent per 1,000 m, which is why aircraft and mountain substations need wider gaps.

Where the conversion bites in practice

  • Dielectric strength data is quoted in kV/mm in Europe and V/mil in the US. A 3 kV/mm rating is 3,000 kV/m, and it is also 76 V per mil.
  • Safety standards set exposure limits in kV/m: the public guideline at power frequency is 5 kV/m, which is 50 V/cm, and the field under a 400 kV line at ground level is typically about 5 kV/m.
  • ESD testing sometimes describes the field rather than the voltage: 100 V across a 1 mm air gap is 100 kV/m just before breakdown.
  • Electrophoresis and electroporation are specified in V/cm, so a 200 V/cm gel run is 20,000 V/m and 0.2 kV/cm; the units are chosen so the number stays between 1 and 1,000.

The recurring theme is that field is voltage divided by distance, so a small change in gap changes the field more than a small change in voltage. A 1 mm gap at 3 kV is 3 MV/m, already at the breakdown limit for air, while the same 3 kV across 10 mm is 300 kV/m and perfectly safe.

Common mistakes

Field is not potential

A 400 kV line has a voltage of 400 kV to earth, but the field at the ground beneath it is only about 5 kV/m. Quoting the voltage as if it were a field is a category error: volts measure potential difference between two points, volts per metre measures the gradient at one point. To get from one to the other you need the distance.

The centimetre version is a hundred, not ten

Because 1 kV/cm is 100 kV/m, a 30 kV/cm air breakdown becomes 3,000 kV/m, not 300. The factor is 100, and it comes from the centimetre being 0.01 m. Checking against the familiar 3 MV/m figure is the fastest way to catch a slip.

Rounded values are the other hazard. Air breakdown is often written as 3 MV/m for a uniform field with polished spheres, but a needle point or a humid day can take it down by a factor of two or more. Design to the worst case for the geometry you actually have, not to the handbook number.

  • 1 kV/cm is 100 kV/m, so the 30 kV/cm breakdown strength of air is 3,000 kV/m rather than 300.
  • Field is voltage divided by distance: 3 kV across 1 mm is 3 MV/m at the breakdown limit, while the same 3 kV across 10 mm is 300 kV/m.
  • N/C and V/m are identical, so a 1,000 V/m field is also 1,000 N/C and needs no factor at all.

Precision and rounding

The factors are exact, so the conversion is exact. Measurements are not: field mills and capacitive probes are good to a few percent, and the field near a conductor varies so steeply that probe position matters more than meter accuracy. Quote two significant figures unless you have a calibrated, mapped setup.

Very large fields exhaust the display quickly. A laser plasma at 109 V/m is 107 kV/cm, and the converter prints it in scientific notation rather than as a long string of zeros. Stay in V/m at that scale and the exponent does the work.

Frequently asked questions

How many volts per metre is 1 kV/m?

1,000 V/m. The kilo prefix is an exact thousand, so 5 kV/m is 5,000 V/m and 0.2 kV/m is 200 V/m. Most outdoor field measurements are quoted in kV/m.

Is N/C the same as V/m?

Yes, exactly. One volt is one joule per coulomb and one joule is one newton-metre, so the metre cancels and a newton per coulomb equals a volt per metre. The two units are used interchangeably.

How many kV/m is 1 kV/cm?

100 kV/m. A centimetre is 0.01 m, so dividing by a smaller distance raises the field by 100. A 30 kV/cm breakdown strength is 3,000 kV/m.

What is the breakdown field of air?

About 3 MV/m at sea level, which is 3,000 kV/m or 30 kV/cm, for a uniform field between polished electrodes. Points, humidity and altitude all reduce it.

How strong is the electric field under a power line?

Typically around 5 kV/m directly beneath a 400 kV line at ground level, which is 50 V/cm. That is six hundred times below air breakdown, but it is at the public exposure guideline of 5 kV/m.

How do I convert V/cm to V/m?

Multiply by 100. A 200 V/cm electrophoresis gel runs at 20,000 V/m. The factor is 100 because there are 100 centimetres in a metre.

What is the fair-weather atmospheric field?

About 120 V/m at ground level on a clear day, pointing downward. It rises to several kV/m under a thundercloud, which is what triggers lightning.

Can an electric field be zero between two charged plates?

No, a uniform field between plates is V/d and is zero only if the voltage is zero. It can be zero at a neutral point between two like charges, where the two fields cancel.

How much field does 1 kV across 1 mm produce?

1,000 kV/m, or 100 kV/cm, or 106 V/m. That is a third of the breakdown strength of air, so a 1 mm gap at 1 kV is usually safe but has little margin.

Method and sources

Calculation basis

Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: November 19, 2026
Formula & data sources
  • Linear conversion through V/m: result = value × factor(from) ÷ factor(to).
  • Factors applied: 1 kV/m = 1000 V/m; 1 N/C = 1 V/m; 1 kV/cm = 100000 V/m.
  • The kilovolt prefixes are exact, and 1 N/C is exactly 1 V/m: the two are the same unit written differently.
  • Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.