CalcSeed

Stair Stringer Layout Calculator

Enter total rise, run and target riser and tread to size a straight staircase.

=
Quick answer: with the default inputs (105 in, 120 in, 7 in, 11 in), the number of risers is 15. At these inputs: riser height = 7, tread depth = 8.57. Change any input to update the result.
Number of risers
—

What this calculator returns

This tool lays out a straight stair run from four inputs and returns the riser count, the actual riser height, the actual tread depth and the stringer length. At the defaults — a 105 in total rise, a 120 in total run, a 7 in target riser and an 11 in target tread — it returns 15 risers, a 7.00 in riser, an 8.57 in tread and a 159.45 in stringer, which is 13.29 ft.

Those four numbers are the whole layout. The riser count fixes every cut on the stringer, the riser height decides comfort, the tread depth decides whether the stair passes code, and the stringer length decides what lumber you buy.

The formula the calculator uses

n=⌈Rrt⌉,L=R2+G2n = lceil R / r_t ceil, L = sqrt{R^2 + G^2}

The riser count rounds up, never down. A 105 in rise divided by a 7 in target is exactly 15, but a 106 in rise would give 15.14 and round to 16 risers, which then makes every riser 6.63 in instead of 7. That rounding is why you always divide the real rise by the chosen count afterward rather than trusting the target.

The tread count is one less than the riser count, because the top riser lands on the upper floor rather than on a tread. The run is then divided by the tread count, not the riser count, which is where most layout errors start.

The stringer is the diagonal of a right triangle with the total rise and total run as its legs. That is the line length along the top edge of the board, before any notching, plumb cuts or landing allowances.

Worked example at the defaults

Risers: 105 ÷ 7 = 15, so 15 risers and an actual riser of 105 ÷ 15 = 7.00 in. Treads: 15 − 1 = 14, so the actual tread is 120 ÷ 14 = 8.57 in.

Stringer: 105² = 11,025 and 120² = 14,400. Their sum is 25,425, and the square root is 159.45 in, or 13.29 ft.

That 8.57 in tread is the number to notice. It is well under the 10 in minimum in the IRC, so this stair is too steep even though the riser height is perfect. The 120 in run is the problem, not the riser count.

2026 stair dimension rules

DimensionCode limitComfortable target
Riser height7.75 in max (IRC)7.0–7.5 in
Tread depth10 in min (IRC)10–11 in
Riser plus treadno code value17–18 in
2 × riser + treadno code value24–25 in
Headroom6 ft 8 in min6 ft 10 in or more
Handrail height34–38 in36 in
Stair width36 in min42 in for two-way traffic

The oldest rule of thumb is the 7-11 stair: a 7 in riser with an 11 in tread. It satisfies both the 17–18 in rule and the 24–25 in rule at once, which is why it feels right underfoot. The default riser passes at 7.00 in; the default tread fails at 8.57 in.

Fixing a run that is too short

Lengthen the run

For 15 risers and a compliant 11 in tread you need 14 × 11 = 154 in of run, not 120 in. That adds 34 in of floor space and pushes the stringer to √(105² + 154²) = 186.39 in, or 15.53 ft, which means buying an 18 ft 2x12 instead of a 16 ft board.

Or add a landing and turn the stair

When the floor plan cannot give up 154 in in a straight line, an L-shaped stair with a landing splits the run into two shorter flights. A landing counts as a tread but is square, so each flight stays within a comfortable riser count and the total footprint drops. The trade-off is more framing and a second stringer set.

Cutting the stringer

The calculated length is the diagonal line, not the board length. A notched stringer needs a plumb cut at the top, a level cut at the bottom and usually 12 in of extra material for clamping and for the birdsmouth that sits on the landing. At 159.45 in, a 14 ft board leaves only 8.5 in of margin, which is why most carpenters buy a 16 ft 2x12 even for this stair. Check the board for crown and mark the notches from the same edge so the treads sit level.

What moves the layout

  • Floor thickness: a 3/4 in hardwood floor on top of the subfloor adds to the finish rise
  • Target riser: dropping from 7 to 6.75 in usually adds a riser and one more tread
  • Nosing: a 3/4–1-1/4 in nosing adds to the effective tread without changing the run
  • Landing thickness: a mid-landing consumes one riser and one tread from the flight
  • Stringer stock: 2x10 is too shallow once the notches are cut, so plan on 2x12

Mistakes that ruin a stair

  • Dividing the run by the riser count instead of the tread count, which makes one tread short
  • Letting the riser heights vary more than 3/8 in, the usual trip-hazard tolerance
  • Forgetting the finish floor thickness, so the top and bottom risers end up unequal
  • Cutting the stringer from a 2x10, which leaves too little wood under the notch
  • Setting the stringers before checking headroom, then finding 6 ft 4 in at the middle

Check the whole stair, not just the numbers

Walk the layout before you cut. Confirm 6 ft 8 in of headroom measured vertically from the tread nosing, a 36 in minimum width clear of the handrail, and a handrail at 34–38 in on at least one side. Where the stair meets a door at the bottom, codes want a landing at least as deep as the door width. None of those appear in the four outputs, but each one can fail an inspection after the stringers are already nailed in.

Frequently asked questions

How many risers do I need for a 105 in rise?

Divide 105 by the target riser. At 7 in that is exactly 15 risers, each 7.00 in tall. At 6.75 in it would be 16 risers of 6.56 in.

What is the 7-11 rule?

A 7 in riser with an 11 in tread. It satisfies the 17–18 in rule and the 24–25 in rule, and it is the geometry most people find comfortable.

Why is my tread only 8.57 in?

Because the default 120 in run is split across 14 treads. A compliant 11 in tread needs 154 in of run for 15 risers, 34 in more than the default.

How long a stringer do I need?

The diagonal of rise and run: √(105² + 120²) = 159.45 in, or 13.29 ft. Buy a 16 ft 2x12 to allow for the plumb and level cuts.

What is the maximum riser height?

The IRC caps residential risers at 7.75 in. Many carpenters hold to 7.5 in or less because taller risers tire people on a long flight.

What is the minimum tread depth?

10 in under the IRC, measured nosing to nosing. The 11 in of the 7-11 rule gives more margin and a better feel underfoot.

How much can riser heights vary?

No more than 3/8 in between the tallest and shortest riser in a flight. Unequal risers are the most common cause of stair falls.

Can I use a 2x10 for the stringer?

Only for a shallow stair. Once a 7 in riser notch is cut from a 9.25 in board, too little wood remains under the notch. Use a 2x12.

How much headroom do I need?

6 ft 8 in minimum, measured vertically from the tread nosing to the ceiling or the floor above. Aim for 6 ft 10 in to allow for finish materials.

Method and sources

Calculation basis

Cost ranges reflect 2026 U.S. national averages for materials and labor; regional pricing varies, so use results as a planning baseline and confirm with local quotes.

Last updated: November 18, 2026
Formula & data sources
  • Standard stair layout uses 7-inch risers, 11-inch treads, and Pythagorean stringer length.

Cite this page

Reference formats
APA 7CalcSeed. (2026, November 18). Stair Stringer Layout Calculator. https://calcseed.com/c/home/stair-stringer-layout-calculator/
MLA 9"Stair Stringer Layout Calculator." CalcSeed, 18 Nov. 2026, calcseed.com/c/home/stair-stringer-layout-calculator/.
ChicagoCalcSeed. "Stair Stringer Layout Calculator." Last modified November 18, 2026. https://calcseed.com/c/home/stair-stringer-layout-calculator/

Related calculators