Radiant Floor Heating Calculator
Enter the floor area and tube spacing to estimate tubing length and heat output.
What this calculator does
Radiant floor heating runs PEX tubing in loops beneath the floor surface and warms the room from the ground up. This calculator takes two inputs — the floor area and the tube spacing — and returns two outputs: the total linear footage of tubing you need to order, and the heat output the floor can deliver in BTU per hour. At the defaults, a 300 sq ft floor at 12 inch spacing works out to 300 linear feet of tube supplying about 9,000 BTU/h.
How the tube length formula works
Each pass of the loop covers one strip of floor as wide as the spacing itself. A 12 inch spacing means every square foot of floor gets one linear foot of tube directly beneath it, because one strip-foot of tube serves one strip-foot of width. Tighten the spacing to 6 inches and the same floor needs twice the tube, since each strip narrows to half a foot. That is the whole relationship: tube length scales inversely with spacing.
Spacing is not arbitrary. Six inches is reserved for high-loss rooms — bathrooms, sunrooms, rooms over unheated garages. Nine inches is the workhorse spacing for living areas in cold climates. Twelve inches suits well-insulated interior rooms and basement slabs with under-slab insulation. Eighteen inches appears only in very low-loss applications such as heated driveways or mild-climate slabs, and it is rarely used inside living space.
Tube per square foot by spacing
| Spacing | Tube per sq ft | Tubing for 300 sq ft | Loops (300 ft max) |
|---|---|---|---|
| 6 in | 2.00 ft | 600 ft | 2 |
| 9 in | 1.33 ft | 400 ft | 2 |
| 12 in | 1.00 ft | 300 ft | 1–2 |
| 18 in | 0.67 ft | 200 ft | 1 |
The loops column matters as much as the length column. Half-inch PEX should stay under roughly 300 feet per loop to keep pressure drop reasonable and heat delivery even, so a floor that needs 600 ft of tube must be split into at least two loops on the manifold, not run as one continuous circuit.
Where the 9,000 BTU/h output comes from
The calculator estimates heat output at 30 BTU per square foot, the typical sustained output of a hydronic floor with supply water around 100–120°F under tile or hardwood. Multiply the area by 30 and you get the floor’s working capacity: 300 sq ft × 30 = 9,000 BTU/h. A 600 sq ft open-plan level would deliver 18,000 BTU/h — comparable to a large space heater, but spread evenly across the floor instead of blowing from one register.
Real output shifts with three things the formula holds fixed: supply water temperature, floor covering, and spacing. Raise the water temperature to 130°F and output climbs toward 40 BTU/sq ft. Cover the slab with thick carpet and it drops toward 20 BTU/sq ft. Tighten spacing from 12 to 6 inches and you can run cooler water yet still hit the same 30 BTU/sq ft, which is why high-loss rooms use tight spacing rather than hotter water.
Worked example: a 300 sq ft great room
Start with the defaults. Area is 300 sq ft and spacing is 12 in, so tube length = 300 × 12 ÷ 12 = 300 ft. Heat output = 300 × 30 = 9,000 BTU/h. Because 300 ft sits right at the practical loop maximum, plan two loops of about 150 ft each rather than one loop of exactly 300 ft; shorter loops run at lower head pressure and heat more evenly.
Scaling up: an 800 sq ft basement slab
Change the area to 800 sq ft and keep 12 inch spacing: tube length = 800 × 12 ÷ 12 = 800 ft, and output = 800 × 30 = 24,000 BTU/h. Divided into three loops of roughly 267 ft each, that fills three ports on a standard manifold and pairs with a small dedicated circulator. If the basement sits over uninsulated earth, drop the spacing to 9 in — 800 × 12 ÷ 9 ≈ 1,067 ft, four loops — to recover the output lost through the slab.
What moves the number
- Spacing: going from 12 in to 6 in doubles the tube count, from 300 ft to 600 ft on a 300 sq ft floor
- Floor covering: thick carpet adds about R-2.5 of resistance and cuts output roughly a third
- Slab edge and under-slab insulation: uninsulated edges can bleed 10–20% of output to the outdoors
- Exterior walls and windows: a room with two glass walls often needs 9 in or 6 in spacing
- Supply water temperature: hotter water means more output per square foot, but costs more to run
Tube length is the one input you control at design time and the only one this calculator measures. The other factors decide whether 30 BTU per square foot is enough, so run the room-by-room heat load first and then choose spacing to match.
Common mistakes that leave you short
- Ordering exactly the calculated length with no margin — add 5–10% for supply tails, bends and miscuts
- Running one 500 ft loop where the layout demands two 250 ft loops, then chasing cold spots near the far end
- Spacing 12 in or wider under carpet, which quietly halves the floor’s output
- Forgetting the runs from manifold to room: a loop 25 ft from the boiler adds 50 ft of tube nobody counted
The last item bites often. This calculator measures tube inside the heated area only. Measure the actual distance from the manifold location to each zone and add it before ordering; on a two-loop job that is commonly 50–100 extra feet.
Buying the right amount of PEX
PEX for radiant work is sold in 100, 300, 500 and 1,200 ft coils. Round up to the next coil size, not the next foot: a job needing 400 ft should buy one 500 ft coil rather than a 300 plus a 100, because mid-loop couplings are a failure point you do not want buried in a slab. On the default 300 sq ft job, order a 500 ft coil and you will finish with a comfortable spare instead of a splice under the concrete.
Radiant floor versus forced air at the same output
A 9,000 BTU/h radiant floor and a 9,000 BTU/h forced-air register heat the same room, but the radiant version runs water at 100–120°F while a forced-air system heats air to 120–140°F and loses duct losses on the way. That efficiency gap is why radiant floors pair so well with modern condensing boilers and heat pumps, which hit their best coefficients of performance at exactly the low water temperatures a tight-spaced, well-insulated slab allows. Tighter spacing lets you run cooler water; cooler water means cheaper heat over the life of the system.
Frequently asked questions
How much tubing do I need per square foot?
At 12 inch spacing, one linear foot of tube per square foot. At 9 inch spacing it is 1.33 ft, and at 6 inch spacing it doubles to 2 ft per square foot. A 300 sq ft floor therefore needs 300 ft at 12 in, 400 ft at 9 in, or 600 ft at 6 in.
What tube spacing should I use?
Twelve inches for well-insulated interior rooms and insulated basement slabs, nine inches for living areas in cold climates, and six inches for high-loss rooms such as bathrooms or rooms over garages. Eighteen inches is generally too wide for occupied living space.
How much heat does a radiant floor produce?
About 30 BTU per square foot at typical water temperatures. This calculator’s default 300 sq ft floor therefore delivers roughly 9,000 BTU/h, and a 600 sq ft level delivers about 18,000 BTU/h.
How long can one PEX loop be?
Keep half-inch PEX loops under roughly 300 ft to limit pressure drop and even out heat along the loop. If the calculated length exceeds 300 ft, split it across multiple manifold loops instead.
What size PEX is used for radiant floors?
Half-inch PEX is standard for residential floors. Five-eighths or three-quarter inch tube appears on long runs or commercial work where lower pressure drop matters.
Can I install radiant heat under carpet?
Yes, but carpet and pad add about R-2.5 of insulation and can cut output by a third. Compensate with tighter spacing, such as 6 in instead of 12 in, or a modestly higher supply water temperature.
How many loops does an 800 sq ft floor need?
At 12 inch spacing it needs 800 ft of tube, which splits into three loops of about 267 ft each on a standard manifold. At 9 inch spacing, plan for about 1,067 ft and four loops.
Should I buy extra tubing beyond the calculated length?
Yes. Add 5–10% for supply and return tails, bends and miscuts, plus the runs from the manifold to each room. Buy the next full coil size up — a 400 ft job takes a 500 ft coil — and avoid mid-slab couplings.
Does tighter spacing let me use cooler water?
Yes. Halving the spacing from 12 in to 6 in puts twice the tube in the floor, so the same 30 BTU/sq ft output can be reached with water 10–20°F cooler, which improves boiler or heat pump efficiency.
Method and sources
- Radiant tube length = area × 12 ÷ spacing; hydronic output ~30 BTU/sq ft.