Floor Transition Calculator
Enter the doorway opening width to estimate the transition strip length.
What this calculator returns
The result is one cut length for one doorway, printed in inches and in feet. At the defaults a 36 in opening with 2 in of overlap on each side returns 40 in, or 3.33 ft. That figure is the length of strip you cut and fasten, not the clear width you walk through. Run it once per doorway: a three-door hallway needs three separate lengths, and each opening should be measured instead of assumed to match the last one.
The measurement formula
Opening width is the clear distance between the finished jambs, taken at floor level rather than up at the header. Measure both sides and the middle, then use the widest reading. A doorway framed in the 1950s is rarely square, and a strip cut to the narrow side shows a gap at one casing that no amount of caulk hides cleanly.
Overlap is how far the strip runs past each jamb onto the adjoining floor. Two inches is the working default because the strip has to be fastened into solid subfloor, not into the thin edge of a casing or the hollow behind drywall. The multiplier of two appears because the strip extends at both ends. Set overlap to zero and the strip stops exactly where there is nothing to nail into, which is why a strip that measured perfectly still lifts at one corner after a season of foot traffic.
Worked example: a 36 inch doorway
A standard interior doorway is 36 in across. With the default overlap the arithmetic is 36 + (2 × 2) = 40 in, and 40 ÷ 12 = 3.33 ft.
Forty inches is not a stock length. Strips ship in 36, 48, 72 and 96 in pieces, so you buy the 48 in strip and trim 8 in off one end. Buying the 36 in piece to save two dollars leaves you 4 in short, and a spliced transition in a doorway catches the light on every pass through it. The offcut is long enough for a closet threshold, so keep it.
Where the overlap actually lands
The 2 in at each end sits on finished flooring on either side of the jamb and covers the joint line where the two floors meet. If the tile on one side is 3/8 in thick, the strip also has to be tall enough to bridge that step, not just long enough to reach across it. Length and profile height are separate decisions; this tool settles only the first one.
Profiles and the length each one needs
| Situation | Profile | Typical width | Length rule |
|---|---|---|---|
| Same-height hard floors | T-molding | 2 in | opening + 2 in per side |
| Drop up to ½ in | Reducer | 2¼ in | same rule |
| Drop over ½ in | Threshold | 4 in | add ¾ in for casing |
| Carpet to hard floor | End cap or tack strip | 1½–2 in | add 1 in for pile |
| Exterior door | Sill with seal | 5 in | fit inside jamb legs |
Profile width and strip length are independent variables. A 4 in threshold on a 36 in opening still needs 40 in of length; the extra width runs out into the room, not along the wall. The one case where the length rule changes is an exterior door, where the sill has to sit between the jamb legs rather than overlapping flooring on both sides, so you measure the jamb-to-jamb distance and add nothing.
What changes the length
- Opening width is the only input that scales linearly: every extra inch of opening adds one inch of strip.
- Deep craftsman casing can swallow the 2 in overlap, so add 1 in per side on a thick trim profile.
- Floors that are out of square by more than ¼ in need the widest of three measurements, not the average.
- An exterior door reverses the rule and needs the jamb-to-jamb distance instead of opening plus overlap.
- A pocket door with a flush track leaves no jamb face, so the strip runs wall to wall.
Only the first and fourth items on that list touch the number this tool prints. The rest change which profile you buy or where you place the cut, which is why a strip that fits one doorway in a house rarely fits the next one, even when both doors are nominally 36 in.
Where people come up short
The most common failure is measuring the door slab instead of the opening. A 36 in slab hangs inside a rough opening closer to 38 in, and once the jamb and casing are on, the finished clear width can be 34½ in. Measuring the slab and adding 4 in gives a strip that overhangs the casing on both ends and has to be re-cut, or worse, a strip bought to the slab width that leaves a 3/4 in gap at each side.
- Cutting to the narrow side of an out-of-square opening leaves a visible gap at one casing.
- Forgetting that the strip must land on floor, not on the jamb face, shortens the usable bearing by an inch per side.
- Trimming a 48 in strip to 40 in without squaring the end first leaves one end proud by up to ¼ in.
Height difference decides the profile
Length is settled first, then height. A T-molding bridges two floors that sit within about 1/8 in of each other and relies on a spline or track underneath. Once the drop passes ½ in, a T-molding starts to rock underfoot and a reducer takes over. Past 1 in, a threshold with a sloped face is the only profile that does not become a trip hazard in a main walkway.
Measuring the step
Set a straightedge across the higher floor and measure down to the lower one at both jambs. If the two readings differ by more than 1/8 in, the subfloor is out of level and the wider reading governs, because the strip sits on the high side and ramps down. Write both numbers on the back of the strip before you cut; the second doorway in the same hall is often a different height.
Buying and cutting
Buy the next stock length above your cut length, never the length below it. For the default 40 in doorway that means a 48 in strip, which also covers any measuring error up to 8 in. Prices run roughly $12–$30 for a 48 in unfinished oak T-molding and $18–$45 for a matching reducer, with prefinished aluminum thresholds at $25–$60 depending on width.
Cut with a fine-tooth blade and score the prefinished face with tape to stop tear-out. Test-fit before fastening: the strip should sit flat with the 2 in bearing on each side and no rock in the middle. Fasten through the spline or track rather than the face so the strip can be lifted later without destroying it, and leave the flooring expansion gap intact underneath.
Frequently asked questions
How long should a transition strip be for a 36 inch door?
40 in with the default 2 in overlap on each side, which is 3.33 ft. Buy a 48 in strip and trim 8 in, since 40 in is not a stock length.
How much overlap do I need past the jamb?
Two inches per side is the working figure. The strip needs solid subfloor to fasten into, and 2 in clears the casing thickness on most interior trim.
Can I use a 36 inch strip on a 36 inch opening?
No. It would end exactly at both jambs with no bearing on the floor, and it would leave no room for the ¼–3/8 in expansion gap. You need 40 in for that opening.
What is the difference between a T-molding and a reducer?
A T-molding joins two floors of the same height and sits flat, typically 2 in wide. A reducer has a sloped face for a drop up to about ½ in and is usually 2¼ in wide.
How do I measure a doorway that is out of square?
Take three readings at floor level, one at each jamb and one in the middle, and use the widest. Out-of-square openings commonly differ by ¼–½ in, which is visible on a finished strip.
What width transition covers a half inch height difference?
A 2¼ in reducer handles a ½ in drop. Past ½ in the slope gets steep enough to trip on, so move up to a 4 in threshold.
Do I still leave an expansion gap under the strip?
Yes, keep the ¼–3/8 in gap the flooring maker specifies on each side. The overlap covers it, and the strip is fastened to the subfloor rather than pinning both floors together.
How much strip do three doorways need?
Three separate measurements, not one multiplied by three. Three 36 in openings at 2 in overlap come to 120 in total, or 2½ sticks of 48 in if the offcuts are long enough to reuse.
Does an exterior door use the same length rule?
No. An exterior threshold sits between the jamb legs, so measure jamb to jamb and add nothing. That is typically 2–4 in shorter than the same width measured as an interior opening plus overlap.
Method and sources
- Transition strip length = opening width + 2 × overlap.