Stair Stringer Calculator
Enter the total rise, desired riser height and tread depth to size stair stringers.
What this calculator returns
You enter three numbers — total rise, a desired riser height and a tread depth — and the tool returns four: the number of risers, the number of treads, the actual riser height after the rise is split evenly, and the stringer length measured along its angled edge. At the defaults of 96 in of rise, a 7 in riser target and a 10 in tread, that is 14 risers, 13 treads, 6.86 in per riser and a 161.6 in stringer, or about 13 ft 6 in.
The stringer formula
Rise is the finished floor to finished floor height, measured with a level and a tape — not the height of a single step. Run is horizontal: the tread count multiplied by the tread depth. With 13 treads at 10 in the run is 130 in, so the stringer is the hypotenuse of a right triangle with a 96 in leg and a 130 in leg.
The riser count always rounds up, because a stair that lands 2 in below the upper floor is not a stair. Dividing 96 by 7 gives 13.71, which becomes 14 risers, and the real riser height is then 96 ÷ 14 = 6.86 in — comfortably under the 7.75 in ceiling in the International Residential Code. Treads are always one fewer than risers because the upper floor itself acts as the last tread.
Tread depth is a separate input because it changes the run, not the step count. Moving from a 10 in tread to 11 in on this flight adds 13 in of run and stretches the stringer to 172.2 in. Tread choice therefore moves your lumber length more than riser choice does.
Worked example at the defaults
Start with a 96 in rise. 96 ÷ 7 = 13.71, rounded up to 14 risers. Check the riser: 96 ÷ 14 = 6.857 in, so every step rises 6.86 in. Treads: 14 − 1 = 13. Run: 13 × 10 = 130 in. Stringer: √(96² + 130²) = √(9,216 + 16,900) = √26,116 = 161.6 in, or 13 ft 6 in.
That length fits on a 14 ft 2×12 with about 6 in to spare before the notches are cut. Raise the floor to 108 in with the same 7 in target and you need 16 risers, 15 treads, a 150 in run and a 184.8 in stringer — 15 ft 5 in, which only fits on a 16 ft board.
Stringer length by total rise
| Total rise | Risers | Treads | Run at 10 in | Stringer |
|---|---|---|---|---|
| 84 in (7 ft) | 12 | 11 | 110 in | 138.4 in |
| 96 in (8 ft) | 14 | 13 | 130 in | 161.6 in |
| 108 in (9 ft) | 16 | 15 | 150 in | 184.8 in |
| 120 in (10 ft), 7.5 in riser | 16 | 15 | 150 in | 192.1 in |
| 96 in, 11 in tread | 14 | 13 | 143 in | 172.2 in |
Two patterns show up in the table. Taller floors add both risers and treads, so the stringer grows faster than the rise does — a 12 in jump in rise costs 23 in of stringer. A longer tread adds length without changing the step count, which is why the last row has the same 14 risers as the second row but a stringer 10.6 in longer.
The 7-11 rule and the code floor
Where the 7-11 rule comes from
A 7 in riser paired with an 11 in tread is the classic comfortable stair, and the reason is leg geometry rather than regulation. A comfortable step satisfies 2R + T ≈ 25 in. At the defaults, 2 × 6.86 + 10 = 23.7 in, which is slightly steep; a true 7 in riser with an 11 in tread hits 25 in exactly, which is why that pairing gets repeated so often.
Code is a floor, not a target. The IRC caps risers at 7.75 in and requires a minimum 10 in tread, with nosing making the effective walking depth 11 in or more. The stricter rule is consistency: the tallest and shortest riser in one flight may not differ by more than 3/8 in. That is why you divide the total rise once and use that single number for every notch instead of eyeballing each step.
Cutting and fitting the stringer
Lay out the board with a framing square and stair gauges set to the riser and tread values. The top notch is set back from the end of the board by one riser so the stringer meets the header flush, and the bottom is notched to sit on the landing.
- Use the calculated riser (6.86 in), never the nominal 7 in.
- Lock the stair gauges so every notch repeats exactly.
- Subtract the tread thickness from the top cut of each notch or the top step sits high.
- Cut one stringer, test-fit it, then use it as a template for the rest.
- Leave the bottom long enough to notch around the landing thickness.
What moves the number
- Total rise: 12 in more floor height adds about 2 risers and 20 in of run at a 7 in target.
- Riser target: on a 96 in rise, dropping from 7.5 in to 7 in goes from 13 risers to 14 and adds 10 in of run.
- Tread depth: every extra inch adds one full tread depth to the run, 13 in at these defaults.
- Landings: a mid-flight landing splits the work into two shorter stringers and resets the notch layout.
- Nosing and tread thickness: they change the cuts and the finished height, not the calculated hypotenuse.
Mistakes that leave you short
The most common error is measuring the rise from the basement slab to the top of the first tread instead of to the finished upper floor. That undercounts by one riser and leaves the whole flight low. Measure finished floor to finished floor, including the thickness of the flooring above.
The second is confusing stringer length with board length. You cannot buy a 161.6 in board, and the top notch plus the bottom plumb cut consume another 10–14 in. A 14 ft 2×12 is the true minimum for this flight; 16 ft is the safe purchase, and it is the length most yards stock.
Wide stairs need more than two stringers. Up to roughly 36 in of width, three stringers — two outer and one center — is standard. Beyond that, add one every 16–24 in on center so the treads do not deflect under a footfall.
Open versus closed stringers
Open stringers show the sawtooth profile and need a full 2×12 so the remaining wood under each notch still carries load. Closed stringers hide the notches behind risers and can be built from a narrower board with glued and screwed cleats. Closed stairs use more material and about 1 in more depth, but they stiffen the flight and stop dust from sifting through the treads.
Frequently asked questions
How many risers do I need for an 8-foot ceiling?
For a 96 in finished rise at a 7 in target, 96 ÷ 7 = 13.71, so you build 14 risers of 6.86 in each and 13 treads. That gives a 130 in run at a 10 in tread and a 161.6 in stringer.
What is the 7-11 rule for stairs?
A 7 in riser with an 11 in tread satisfies 2R + T = 25 in, the classic comfortable step. The defaults here give 2 × 6.86 + 10 = 23.7 in, which is a slightly steeper stair than the rule describes.
How long is a stringer for a 96 in rise?
161.6 in with 10 in treads, which works out to 13 ft 6 in. Use 11 in treads and the run grows to 143 in, pushing the stringer to 172.2 in.
How many stringers do I need for a 36 in wide stair?
Three: two outer stringers and one in the center. Add another for every 16–24 in of extra width so the treads stay stiff.
Can I cut this stringer from a 14 ft 2x12?
Yes for a 161.6 in stringer, but only just. The top notch and bottom plumb cut eat 10–14 in, so a 16 ft board is the safer buy and leaves room for a mistake.
What is the maximum riser height allowed?
The IRC caps risers at 7.75 in and requires treads of at least 10 in. The 3/8 in rule also forbids more than 3/8 in of variation between the tallest and shortest riser in a flight.
Why are there fewer treads than risers?
Because the upper floor is the final tread. A 14 riser flight has 13 cut treads; the 14th step is the landing surface you walk onto.
What tread depth should I use?
10 to 11 in covers most residential stairs. At 10 in on a 96 in rise the run is 130 in; at 11 in it is 143 in, a 13 in difference in floor space.
How do I measure total rise?
Measure from the finished lower floor to the finished upper floor, including flooring thickness on both levels. Measuring to the top of the first tread undercounts by one riser and makes the flight short.
Method and sources
- Stair stringer length via Pythagorean theorem; standard riser height and tread depth ranges.