Generator Size Calculator

Enter the running watts of your essential appliances to estimate the generator size.

=
Quick answer: with the default inputs (700 W, 800 W, 600 W, 300 W), the recommended generator is 4,500. At these inputs: running watts = 3,400, starting watts = 4,400. Change any input to update the result.
Recommended generator
—

What this calculator does

This calculator sizes a backup generator in watts from the appliances you plan to run during an outage. At the default inputs — a refrigerator, sump pump, furnace fan, lights and outlets, and a well pump — the running load is 3,400 W, the starting load is 4,400 W, and the recommended generator is 4,500 W. That last figure is the number to take shopping.

How generator sizing works

Every appliance has a running wattage, the continuous draw while it operates. Motors such as pumps and furnace fans also have a starting surge, a brief spike of one and a half to three times their running draw when they kick on. Adding every running watt gives the steady load; adding the surge of the single largest motor gives the worst simultaneous peak, since two big motors rarely start at the exact same moment.

Ps=Pr+PmP_s=P_r+P_m

Worked example

Take the defaults: refrigerator 700 W + sump pump 800 W + furnace fan 600 W + lights and outlets 300 W + well pump 1,000 W = 3,400 W running. The largest motor is the well pump at 1,000 W, so starting watts = 3,400 + 1,000 = 4,400 W. Generators are sold in steps (2,000 / 3,500 / 5,000 / 7,500 W), so the calculator rounds up to the next common size: 4,500 W.

Typical appliance wattages

ApplianceRunning wattsStarting surge
Refrigerator600–800 W1,200–2,000 W
Sump pump (½ hp)800–1,050 W1,300–2,600 W
Furnace fan (¼ hp)600–700 W1,000–2,300 W
Well pump (⅓ hp)750–1,100 W1,500–3,000 W
LED lights & phone chargers100–300 Wnone

Check the nameplate or plug each appliance into a $15 watt meter rather than trusting generic tables — an older refrigerator can draw 50 percent more than a modern one, and deep-well pumps pull far more than shallow ones.

What moves the recommended size

  • Which appliances run simultaneously — only count the load during the worst hour of an outage, not everything you own
  • The largest motor, because its surge sets the peak the generator must absorb
  • Adding a window air conditioner (1,000–1,500 W running, 2,000–3,000 W starting) jumps the requirement by a full size class
  • Whether you choose an inverter generator, which tolerates surges gracefully, or a conventional unit
  • Future needs: a transfer switch installed now makes adding circuits cheap later

Common sizing mistakes

  • Summing every appliance in the house instead of the outage-hour essentials
  • Forgetting the well pump or sump pump, the two loads that matter most in a storm
  • Buying exactly at the calculated peak with no margin — leave 10–20 percent headroom for surges stacking
  • Overlooking fuel: a 4,500 W generator burns roughly 0.5–0.7 gallons of gasoline per hour at half load

The opposite mistake is overbuying. A 9,000 W generator sized for a central air conditioner runs at 15 percent load during a normal outage, which wastes fuel and, on conventional units, causes wet stacking and gummed carburetors from prolonged light loading. Inverter generators avoid that penalty, but the cheapest correct plan is still to size for the outage-hour essentials and add circuits only when a real need appears.

What a 4,500-watt generator actually runs

At the defaults, a 4,500 W unit carries all five essentials at once: food stays cold, the basement stays dry, the furnace heats, the well delivers water and lights stay on. It will not run a central air conditioner, an electric water heater, an electric range or a clothes dryer — each of those alone matches or exceeds the entire essential load. Households that want those comforts move to 7,500 W portables or 10,000–20,000 W standby units with automatic transfer switches.

Portable versus standby

A 4,500 W portable costs $500–$1,100 and starts by hand or electric button; a standby unit of comparable essential coverage costs $5,000–$8,000 installed but starts within seconds of an outage and runs on natural gas. For short storm outages the portable covers the same critical circuits through a transfer switch or heavy-duty cords. The transfer switch is the safety line either way: back-feeding a house panel through a dryer outlet is illegal in most jurisdictions and has killed utility linemen.

Fuel runtime planning

Sizing is only half the plan; fuel is the other half. A typical 4,500 W portable consumes about 3–4 gallons of gasoline in 8 hours at half load, so a 3-day outage needs 15–20 gallons stored safely away from the house. Inverter models of the same rating stretch that by 30–40 percent at low loads. If your essentials are the calculator defaults, the electrical load calculator helps when you later want whole-house capacity, and the sump pump size calculator confirms the pump wattage you entered here.

Frequently asked questions

What size generator do I need for a house outage?

Add the running watts of the essentials you will run together, add the surge of the largest motor, and round up to the next common size. The defaults here land on a 4,500 W generator for refrigerator, sump pump, furnace, lights and well pump.

What is the difference between running and starting watts?

Running watts is the continuous draw while operating; starting watts is the brief surge when a motor spins up, often 1.5–3 times its running draw. Generators must cover both.

Will a 4,500-watt generator run a house?

It runs the essentials — fridge, sump pump, furnace fan, lights and well pump total 3,400 W running at these defaults. It will not run central air, an electric range or an electric dryer.

Why add only the largest motor’s surge?

Because two large motors almost never start at the same instant. Adding every surge would overestimate the peak and push you to buy a bigger generator than the worst moment requires.

How many watts does a well pump use?

A typical ⅓ hp residential well pump draws 750–1,100 W running and can surge to 1,500–3,000 W at startup, which is why it dominates the sizing in homes with wells.

Can I run a generator without a transfer switch?

Only by plugging appliances in directly with outdoor-rated cords. Connecting a generator to house wiring requires a transfer switch, both by code and to protect utility workers from back-feed.

How much fuel does a 4,500 W generator use?

Roughly 0.5–0.7 gallons of gasoline per hour at half load, or 3–4 gallons over an 8-hour night. A 3-day outage budget is 15–20 gallons.

Should I round up the recommended watts?

Yes. Generators are sold in size steps such as 2,000, 3,500, 5,000 and 7,500 W, and leaving 10–20 percent headroom absorbs stacked motor surges and future loads.

What happens if the generator is too small?

It bogs down and trips its breaker when the largest motor starts, and sustained overload overheats the windings. Undersizing by more than about 20 percent makes outages a juggling exercise.

Do inverter generators change the math?

The wattage math is the same, but inverter units handle motor surges more gracefully and throttle fuel use to the actual load, stretching runtime 30–40 percent at light loads.

Method and sources

Calculation basis

Cost ranges reflect 2026 U.S. national averages for materials and labor; regional pricing varies, so use results as a planning baseline and confirm with local quotes.

Last updated: November 17, 2026
Formula & data sources
  • Generator sizing from running watts plus largest motor starting surge.

Cite this page

Reference formats
APA 7CalcSeed. (2026, November 17). Generator Size Calculator. https://calcseed.com/c/home/power-outage-calculator/
MLA 9"Generator Size Calculator." CalcSeed, 17 Nov. 2026, calcseed.com/c/home/power-outage-calculator/.
ChicagoCalcSeed. "Generator Size Calculator." Last modified November 17, 2026. https://calcseed.com/c/home/power-outage-calculator/