Well Pump Calculator
Enter the well depth, flow rate and pressure to estimate pump horsepower.
What this calculator returns
You get two figures from the same arithmetic. Total head is the vertical distance the pump must push water, in feet, once pressure is converted into an equivalent column of water. Pump horsepower is the water horsepower needed to move your flow rate against that head. Change any input and both update together, so the two numbers always agree with each other.
How total head is built
The depth term is lift: the vertical distance from the pumping water level to the discharge point. Enter the static water level, not the depth you drilled. A 300 ft well with water standing at 60 ft lifts only 60 ft at rest, and reading the drilled depth as lift is the most common way people oversize a submersible by two frame sizes.
The pressure term turns your tank setting into feet of water. One psi supports 2.31 ft of water, so a 40 psi system adds 40 × 2.31 = 92.4 ft on top of the lift. Raising the setting from 40 to 60 psi adds 46.2 ft, which is 24 percent more than the 192.4 ft default and often enough to push a marginal pump onto the next motor size.
The 3960 divisor is unit conversion rather than a fudge factor. One horsepower equals 33,000 ft-lb per minute and a gallon of water weighs 8.34 lb, so 33,000 ÷ 8.34 ≈ 3960. That makes head × GPM ÷ 3960 exact hydraulic power at the impeller, with no efficiency allowance hidden inside the constant.
Worked example at the defaults
The defaults are a 100 ft well, 10 GPM and 40 psi. Head is 100 + 40 × 2.31 = 192.4 ft. Horsepower is 192.4 × 10 ÷ 3960 = 0.486 hp. That is the power delivered to the water, not the motor nameplate rating, and the gap between the two is what determines which pump you actually buy.
To choose a motor, divide by wire-to-water efficiency, which absorbs impeller losses, motor losses and voltage drop in the drop cable. At 55 percent, 0.486 ÷ 0.55 = 0.88 hp, so the well needs a 1 hp motor. At 45 percent, typical of a deep-set pump with 200 ft of drop pipe, the same duty needs 1.08 hp and the next standard frame is 1.5 hp.
Pump sizing at common depths and flows
This table runs the same formula at settings you are likely to meet. Motor size assumes 55 percent wire-to-water efficiency and rounds up to the nearest standard submersible frame: 0.5, 0.75, 1, 1.5, 2, 3 and 5 hp.
| Well depth | Flow | Pressure | Total head | Water hp | Motor at 55% |
|---|---|---|---|---|---|
| 40 ft | 5 GPM | 30 psi | 109.3 ft | 0.14 hp | 0.5 hp |
| 100 ft | 10 GPM | 40 psi | 192.4 ft | 0.49 hp | 1 hp |
| 200 ft | 10 GPM | 50 psi | 315.5 ft | 0.80 hp | 1.5 hp |
| 300 ft | 12 GPM | 60 psi | 438.6 ft | 1.33 hp | 3 hp |
| 500 ft | 15 GPM | 60 psi | 638.6 ft | 2.42 hp | 5 hp |
Read the first two rows against each other. Doubling the static level from 40 ft to 100 ft and adding 10 psi takes the duty from 0.14 hp to 0.49 hp, a 3.4-fold increase, and the motor jumps from 0.5 hp to 1 hp. Head is linear in depth, but the motor steps are not, which is why the cost curve looks jumpy rather than smooth.
What moves the number
- Static water level versus drilled depth: a 300 ft well with water at 60 ft needs 240 ft less lift than one with water at 300 ft
- Pressure setting: every 10 psi adds 23.1 ft of head, about 12 percent more at the 192.4 ft default
- Flow rate, which scales horsepower linearly — 20 GPM doubles 0.486 hp to 0.972 hp at the same head
- Drawdown, where the pumping level falls 20–50 ft in a low-yield well and adds that much head at full flow
- Friction in drop pipe and fittings, roughly 5–15 ft at 10 GPM in 1 in. pipe and considerably more in 3/4 in.
Low-yield wells and short cycling
A well that makes 3 GPM cannot feed a 10 GPM pump continuously. The pump pulls the water level down to the intake, the motor loses its cooling flow and the overload trips, and the cycle repeats until the motor burns out. Size the pump to the well yield rather than to household peak demand, and add a 50–120 gallon storage tank plus a booster if the house still needs 8–10 GPM at the fixtures.
Constant pressure versus a standard tank
A variable-frequency controller holds 50–60 psi at the tap instead of swinging between 40 and 60 psi. That steadier setting means the pump works against 138.6 ft of head rather than 92.4 ft at the top of its range, so the minimum motor size usually climbs one frame step. You trade a larger pump and a soft-start control for a shower that does not surge when the toilet fills.
Mistakes that shorten pump life
- Using drilled depth as the lift figure, which inflates head by 100–200 ft on a deep well with a shallow water table
- Treating the pressure term as zero, when a 40 psi tank already carries 92.4 ft of head
- Buying a motor sized to water horsepower alone, which leaves it running at 90–100 percent load with no margin for drawdown
- Sizing to three fixtures running at once instead of the fixture-unit load that the plumbing code actually calculates
Each mistake fails in a different way. Oversizing from drilled depth wastes $150–$400 on a bigger motor and throttles flow through a valve, which wastes energy every hour. Undersizing the pressure term leaves the pump unable to reach 60 psi on a two-story house. Running at full load shortens motor life from a typical 10–15 years to 6–8, and replacing a submersible means pulling the drop pipe, which is a $500–$1,500 job before the pump is even priced.
Adding margin without oversizing
Add 10 to 15 percent head for future drawdown and another 10 percent for friction when the run from well to house exceeds 100 ft, then round to the next standard motor size and stop there. A 0.486 hp duty belongs on a 1 hp motor. Putting a 2 hp motor on the same well with a 20 gallon tank gives a pump that fills the tank in under a minute, cycles dozens of times a day and wears out its start capacitor long before the impeller wears out.
Frequently asked questions
What size well pump do I need for a 100 ft well?
At 10 GPM and 40 psi the duty is 192.4 ft of head and 0.486 water hp, which lands on a 1 hp submersible once you allow for efficiency. A shallow static level or a 5 GPM flow drops the same well to 0.5 hp.
How many feet of head is 1 psi?
2.31 ft of water. A 40 psi system therefore counts as 92.4 ft of lift and a 60 psi system as 138.6 ft, so the pressure setting alone accounts for nearly half the total head at the defaults.
Is the horsepower here the motor size I buy?
No. The output is water horsepower. Divide by 0.5–0.7 for wire-to-water efficiency and round up to the next standard frame, so 0.486 hp becomes a 1 hp motor at 55 percent efficiency.
Why does my pump need more head than my well is deep?
Because pressure is part of the load. At 40 psi the tank adds 92.4 ft on top of the lift, so a 100 ft well with water at 100 ft requires 192.4 ft of head, not 100 ft.
How much head does pipe friction add?
Allow 5–15 ft per 100 ft of 1 in. drop pipe at 10 GPM, and roughly triple that in 3/4 in. pipe. A 200 ft run in 3/4 in. can add 60–90 ft, which is another full motor size.
Can I run a 3 GPM well with a 10 GPM pump?
Not continuously. The pump will draw the level down to the intake and trip on overload within minutes. Match the pump to the 3 GPM yield and store water in a 50–120 gallon tank to cover peak demand.
What pressure should I set my well tank to?
40/60 psi is the common residential setting and gives 92.4–138.6 ft of head. A 30/50 setting lowers the head by 23 ft but leaves weak pressure on a second floor.
Does a deeper well always need a bigger pump?
No. Head follows the static water level, not the drilled depth. A 400 ft well with water at 50 ft needs less lift than a 150 ft well with water at 140 ft, and the pump sizes accordingly.
How do I convert GPM to pump horsepower?
Use head × GPM ÷ 3960. At the defaults that is 192.4 × 10 ÷ 3960 = 0.486 hp, and at 20 GPM the same head needs 0.972 hp.
Method and sources
- Total head = depth + psi × 2.31; water hp = head × GPM ÷ 3960.