Heat Pump Calculator

Enter your home area and climate to estimate the heat pump capacity in tons.

=
Quick answer: with the default inputs (1,500 sq ft, mild), the heat pump size is 3.13. At these inputs: cooling capacity = 37,500. Change any input to update the result.
Heat pump size
—

What this calculator returns

You enter the conditioned floor area and a climate band, and the tool returns two numbers: capacity in BTU per hour and the same capacity expressed in tons, where one ton equals 12,000 BTU/h. At the defaults — 1,500 sq ft in a mild climate — it returns 37,500 BTU/h, which is 3.125 tons.

The sizing formula

t=A·f12000t=\frac{A\,f}{12000}

Three inputs, one multiplication and one division. A is the conditioned floor area in square feet and f is the climate factor in BTU per square foot. Multiply them to get the peak load; divide by 12,000 because residential equipment is bought and quoted in tons of cooling capacity, not in BTU.

The climate factors are 25 BTU per sq ft for mild, 30 for hot and 35 for cold. They exist because the same house leaks more heat through its envelope as the outdoor design temperature falls and gains more as it climbs. A 1,500 sq ft house therefore needs 37,500 BTU/h in a mild market and 52,500 BTU/h in a cold one — a gap of 1.25 tons that comes from climate alone.

Why a ton is 12,000 BTU

One ton of cooling was originally the rate at which a ton of ice absorbs heat while melting over 24 hours: 2,000 lb × 144 BTU/lb ÷ 24 h = 12,000 BTU/h. The unit survived the ice trade and now just describes compressor capacity.

Worked example at the defaults

Take 1,500 sq ft in a mild climate. Capacity = 1,500 × 25 = 37,500 BTU/h. Tons = 37,500 ÷ 12,000 = 3.125 tons. Because equipment ships in half-ton increments, the real choice is between a 3-ton unit rated 36,000 BTU/h and a 3.5-ton unit rated 42,000 BTU/h.

The 3-ton option is 4% below the calculated load and the 3.5-ton option is 12% above it. On a house with average insulation the 3-ton unit is the closer match, and any shortfall during the coldest week is covered by the auxiliary heat strip that every split system already carries. Choosing the 3.5-ton unit to be safe buys 4,500 BTU/h you pay for in short cycling.

Capacity by home size and climate

Every cell below is area × factor ÷ 12,000 using the same constants the calculator uses. Round to the nearest half ton; round up rather than down when the house is poorly insulated, has a lot of west-facing glass, or has ceilings above 9 ft.

Home areaMild (25 BTU/sq ft)Hot (30 BTU/sq ft)Cold (35 BTU/sq ft)
1,000 sq ft2.1 tons2.5 tons2.9 tons
1,500 sq ft3.1 tons3.8 tons4.4 tons
2,000 sq ft4.2 tons5.0 tons5.8 tons
2,500 sq ft5.2 tons6.3 tons7.3 tons
3,000 sq ft6.3 tons7.5 tons8.8 tons
4,000 sq ft8.3 tons10.0 tons11.7 tons

Read across a row to see what climate costs in equipment: at 2,000 sq ft the swing from mild to cold is 4.2 to 5.8 tons, roughly 40% more machine and a similar jump in installed price. Read down a column and the area effect is close to linear, about one ton per 480 sq ft in the mild band.

What moves the number beyond floor area

  • Insulation and air sealing. A tight house with R-19 walls and R-49 attic can run 20–30% below the table; a 1950s house with single glazing can run 30% above it.
  • Ceiling height. The factors assume 8 ft ceilings. A 12 ft great room holds 50% more air volume and adds load in proportion.
  • Window area and orientation. West glass gains roughly 30 BTU per sq ft of glazing on a summer afternoon, so 200 sq ft of west-facing windows adds about 6,000 BTU/h, or half a ton.
  • Climate banding is coarse. Mild covers everything from Seattle to Atlanta. Use the cold column whenever your winter design temperature is below 20°F, even if your summers are mild.

What the equipment costs

Installed prices in 2026 for a complete split-system heat pump, including line set, air handler, thermostat, refrigerant charge and permit. Equipment alone is 45–55% of the total; labour, attic access, electrical upgrade and disposal make up the rest.

  • 2 ton (24,000 BTU/h): $6,000–$9,500 installed
  • 3 ton (36,000 BTU/h): $7,500–$12,500 installed
  • 4 ton (48,000 BTU/h): $9,500–$15,500 installed
  • 5 ton (60,000 BTU/h): $11,500–$18,500 installed

The 3-ton system your defaults point to sits at $7,500–$12,500 before rebates. A ductless mini-split of the same capacity runs $4,500–$8,000 installed but needs one head per zone, so a three-zone house usually costs more than a ducted system. Add $1,200–$2,500 if the panel needs a dedicated 240 V circuit.

Energy cost: what SEER2 and HSPF2 buy

Ratings decide the operating bill, not the size. Cooling energy is capacity × full-load hours ÷ SEER2; heating energy is capacity × full-load hours ÷ HSPF2. At 3.125 tons with 1,500 cooling hours, 1,000 heating hours and electricity at $0.17/kWh, the same 37,500 BTU/h machine costs:

EfficiencyCooling per yearHeating per yearCombined
SEER2 14.3 / HSPF2 7.5$669$850$1,519
SEER2 16 / HSPF2 8.5$598$750$1,348
SEER2 18 / HSPF2 10$531$638$1,169

Stepping from 14.3 to 18 SEER2 saves $138 a year on cooling at these hours. The price premium for that step is roughly $1,800, so the simple payback is about thirteen years in a mild climate and under seven in a hot one running 2,500 cooling hours.

Heat pump versus a 95% gas furnace

Per 100,000 BTU delivered, a heat pump at HSPF2 7.5 draws 13.3 kWh, or $2.27 at $0.17/kWh. A 95% AFUE furnace burns 1.05 therms, or $1.16 at $1.10 per therm. Gas is roughly half the cost at those prices, and the two reach parity near $0.10/kWh electricity.

Undersizing, oversizing and when to pay for a Manual J

An undersized heat pump never reaches setpoint on the design day and falls back on resistance strips, which deliver heat at roughly one third the efficiency of the compressor. An oversized one satisfies the thermostat in short bursts, never runs long enough to dehumidify, and cycles three to five times more often than it was built for. Both failures show up as a higher bill rather than a visible fault.

Manual J is the ACCA load calculation the IRC points to, and it replaces every factor here with a room-by-room envelope model: window U-values, duct losses, infiltration in air changes per hour, internal gains. It usually lands within 10–15% of the rule of thumb for average construction, and further off for unusual glazing.

Pay for the full calculation when the house predates 1980, when you are replacing a system that never felt right, when more than 30% of wall area is glass, or when the quote passes $12,000. For a like-for-like swap in a tract house, this table plus a contractor walk-through is enough.

Frequently asked questions

How many tons of heat pump do I need for a 1,500 sq ft house?

In a mild climate the calculator returns 1,500 times 25, which is 37,500 BTU/h or 3.125 tons, so you would buy a 3-ton or 3.5-ton unit. In a cold climate the same house returns 52,500 BTU/h, or 4.375 tons.

How many BTU per square foot for a heat pump?

This tool uses 25 BTU per sq ft for mild climates, 30 for hot and 35 for cold. Older, leaky houses often need 40 or more, and a well-sealed new build can come in near 20.

Is 3 tons enough for a 2,000 square foot house?

Only in the mild band. At 2,000 sq ft the mild factor gives 50,000 BTU/h or 4.17 tons, so a 3-ton unit would be roughly 28% short. Hot needs 5.0 tons and cold 5.8 tons at the same area.

What is a heat pump ton?

A rate of heat transfer equal to 12,000 BTU per hour, originally the cooling delivered by melting one ton of ice in 24 hours. A 3-ton heat pump moves 36,000 BTU/h at rated conditions.

How much does a 3-ton heat pump cost installed?

Expect $7,500 to $12,500 in 2026 for a complete split system with air handler, line set and permit. Equipment is about half; the rest is labour, electrical work and disposal.

Does a higher SEER2 rating pay for itself?

At 1,500 cooling hours and $0.17/kWh, moving from 14.3 to 18 SEER2 saves about $138 a year, so the $1,800 premium takes about thirteen years to repay. In a hot climate the payback drops under seven years.

Is a heat pump cheaper to run than a gas furnace?

At $0.17/kWh and $1.10 per therm, a 95% furnace costs about $1.16 per 100,000 BTU delivered while an HSPF2 7.5 heat pump costs about $2.27. They reach parity near $0.10/kWh electricity.

What happens if I oversize a heat pump?

It satisfies the thermostat in short bursts, so it never runs long enough to remove humidity, and it cycles three to five times more often than needed. A 5-ton unit on a house that needs 3 tons is 60% excess.

Should I size for heating or cooling?

Size for whichever load is larger. In cold climates the heating load usually wins, which is why the cold factor is 35 rather than 25 BTU per sq ft; in hot-dry climates cooling sets the size.

Is this a real load calculation?

No. It is a rule of thumb that lands within 10 to 15% of a Manual J result for average construction. Get a Manual J if the house is pre-1980, heavily glazed, or the quote exceeds $12,000.

Method and sources

Calculation basis

Cost ranges reflect 2026 U.S. national averages for materials and labor; regional pricing varies, so use results as a planning baseline and confirm with local quotes.

Last updated: November 17, 2026
Formula & data sources
  • Heat pump sizing: area × climate factor (25–35 BTU/sq ft) ÷ 12,000 for tons.