Shower Pan Calculator
Enter the shower dimensions and membrane upturn to estimate the pan and membrane area.
What the calculator measures
You get three numbers: the floor area of the pan in square feet, the perimeter in feet, and the waterproofing membrane area that covers the floor plus the upturn at each wall. At the defaults, a 48 in by 36 in shower has a 12 sq ft pan, a 14 ft perimeter and 19 sq ft of membrane.
The formula
Pan area is width × length ÷ 144, because the dimensions arrive in inches and 144 sq in make a square foot. Perimeter is 2 × (width + length) ÷ 12 to get feet. Membrane area is the pan plus the perimeter multiplied by the upturn converted to feet, so a 6 in upturn is 0.5 ft.
The upturn is the part people skip. Water that reaches the base of the wall wicks upward behind the tile and the backer board, so the liner has to run up the wall at least 3 in above the curb, and 6 in is the common detail. Each extra inch of upturn on the default pan adds 1.17 sq ft, which is why raising it from 6 to 12 in costs 7 sq ft.
The result is membrane area, not membrane purchased. A liner is cut from a sheet and folded at the corners, and every fold consumes roughly a square foot that ends up under the wall. Buy a sheet at least 25% larger than the computed area: 19 sq ft becomes a 5 ft by 5 ft sheet at 25 sq ft, which is the smallest standard size that covers it.
Worked example at the defaults
48 in wide, 36 in long, 6 in upturn. The floor is 48 × 36 = 1,728 sq in, and 1,728 ÷ 144 = 12 sq ft. The perimeter is 2 × 84 = 168 in, or 14 ft. The membrane is 12 + 14 × 0.5 = 19 sq ft.
- Pan: 48 × 36 = 1,728 sq in ÷ 144 = 12 sq ft
- Perimeter: 2 × (48 + 36) = 168 in ÷ 12 = 14 ft
- Upturn: 6 in ÷ 12 = 0.5 ft
- Membrane: 12 + 14 × 0.5 = 19 sq ft
Nineteen square feet covers a 12 sq ft floor, so the upturn is 37% of the total. That ratio explains two things: a 3 in upturn instead of 6 in saves only 3.5 sq ft, and a 12 in upturn adds more than half a pan again. Cutting the upturn to save liner is a false economy on a job this size.
Pan and membrane by shower size
| Shower | Pan area | Perimeter | Membrane at 6 in |
|---|---|---|---|
| 30 × 30 in | 6.3 sq ft | 10 ft | 11.3 sq ft |
| 36 × 36 in | 9 sq ft | 12 ft | 15 sq ft |
| 36 × 48 in | 12 sq ft | 14 ft | 19 sq ft |
| 36 × 60 in | 15 sq ft | 16 ft | 23 sq ft |
| 42 × 60 in | 17.5 sq ft | 17 ft | 26 sq ft |
| 48 × 48 in | 16 sq ft | 16 ft | 24 sq ft |
The membrane grows with the perimeter as well as the floor. The 36 × 60 in tub replacement has 25% more floor than the 48 × 36 in shower and 21% more membrane, while the 48 in square has 33% more floor than the 36 in square but 60% more membrane, because it carries 4 ft of extra perimeter.
Upturn changes the order
| Upturn | Membrane area | Sheet to buy |
|---|---|---|
| 3 in | 15.5 sq ft | 20 sq ft |
| 4 in | 16.7 sq ft | 21 sq ft |
| 6 in | 19 sq ft | 25 sq ft |
| 9 in | 22.5 sq ft | 30 sq ft |
| 12 in | 26 sq ft | 35 sq ft |
The sheet column is the computed area plus 25%, rounded to a size a supplier stocks. Above 6 in you are usually waterproofing a seat, a bench or a window sill, and those get their own pieces rather than a taller upturn all round. A 40 mil PVC liner at $1–$2 per sq ft makes the difference between a 25 sq ft and a 35 sq ft sheet $10–$20, which is not the place to economize.
Slope, mortar and the drain
Building the preslope
The pan slopes 1/4 in per ft to the drain. On the default shower the long dimension is 4 ft, so the perimeter sits 1 in above the drain, and the short dimension is 3 ft, so that side is 0.75 in above it. The preslope goes under the liner, with a minimum of 3/4 in of mud at the drain so the clamping ring has something to sit on.
A preslope averaging about 1.1 in over 12 sq ft is 1.1 cu ft of deck mud. Sand-topping mix yields about 0.5 cu ft per 60 lb bag, so that is 2.2 bags, or 3 bags to buy. The same again for the final bed above the liner, which makes 6 bags of 60 lb for a complete pan, or about 360 lb of mix.
The drain and the weep holes
The drain has to be a clamping-ring type with a weep-hole collar, not a glue-on shower drain. The liner is clamped between the two rings and the weep holes let any water that reaches it drain away. Mortar blocking those holes is the most common reason a pan passes a visual inspection and fails a flood test two days later.
Testing and the curb
Plug the drain, fill the pan to the top of the curb and leave it 24 hours. A drop of more than 1/8 in is a leak, and the fix is a new liner, not a patch. Test before the tile goes on, because everything after that point is demolition.
The curb takes its own strip of liner, wide enough to wrap over the top and 3 in down each face. A 6 ft curb with a 2 in wide cap needs a strip about 12 in wide and 7 ft long, allowing 6 in of overlap at each end. That piece is cut from the same roll, so add a square yard to any liner order for the curb and the dam corners.
Where the number stops
- Wall waterproofing above the upturn is not counted. Three walls of the default shower at 5 ft high are about 55 sq ft.
- The mortar, thinset and tile are separate quantities priced by the square foot of finished surface.
- The curb strip and the dam corners add roughly 6 sq ft of liner beyond the computed area.
- A bench or a niche adds its own surfaces and its own pieces, usually 3–6 sq ft each.
Adding it up for the default shower: 19 sq ft of pan membrane, about 55 sq ft of wall board and surface membrane, and 6 bags of mud. That is the real material list behind a 48 in by 36 in stall, and the 19 sq ft figure is the part this calculator answers exactly.
Frequently asked questions
What size shower pan do I need for a 48 by 36 shower?
A 48 × 36 in pan is 12 sq ft with a 14 ft perimeter. With a 6 in upturn you need 19 sq ft of membrane.
How much waterproofing membrane for a shower floor?
Floor area plus perimeter times upturn. A 12 sq ft pan with 14 ft of perimeter and a 6 in upturn is 19 sq ft, so buy a 25 sq ft sheet for the folds.
How high should the shower membrane go up the wall?
3 in minimum above the curb, 6 in typical. Each extra inch on a 14 ft perimeter adds 1.17 sq ft.
What is the slope for a shower pan?
1/4 in per ft. On the default 4 ft run the perimeter is 1 in above the drain, and on the 3 ft run it is 0.75 in.
How much mortar for a shower pan?
About 1.1 cu ft of deck mud for a 12 sq ft preslope averaging 1.1 in, which is 3 bags of 60 lb sand mix. Double it for preslope plus final bed.
Can I use a pre-sloped foam tray instead?
Yes. A 48 × 36 in tray replaces the preslope, which cuts the mud from about 6 bags to 3 and removes the sloped screed work.
How do I test a shower pan for leaks?
Plug the drain, fill to the top of the curb, wait 24 hours. More than 1/8 in of loss means the liner or a corner is leaking.
What is the minimum shower size?
30 × 30 in is the common code minimum. That is 6.3 sq ft of pan and 11.3 sq ft of membrane at a 6 in upturn.
How much does a shower pan liner cost?
A 40 mil PVC liner runs $1–$2 per sq ft, so 19 sq ft is $19–$38. A 5 × 5 ft sheet is $25–$50.
Do I need membrane on the shower walls too?
Yes, above the upturn. Three walls of a 48 × 36 in alcove at 5 ft high is about 55 sq ft, so the full waterproofing is roughly 74 sq ft.
Method and sources
- Shower pan membrane area from floor area plus perimeter upturn.