Insulation Calculator
Enter the area and batt type to estimate insulation batts and cost.
What this calculator estimates
This calculator converts the area you want to insulate into a count of fiberglass batts and a material cost. At the defaults it prices a 40 × 25 ft space — 1,000 sq ft — in R-19 batts: 1,000 ÷ 32 = 31.25, rounded up to 32 batts, which costs $800.00 at $25 per batt. Each batt type in the dropdown carries a different coverage figure, because higher R-value means more glass per batt and less area covered.
The formula
Coverage per batt is what the package promises in open framing: R-13 batts sized for 2×4 walls cover 40 sq ft, R-19 batts for 2×6 walls cover 32 sq ft, and R-30 attic batts cover 25 sq ft. The count is rounded up to a whole batt, which provides most of the waste margin on its own — the default job rounds from 31.25 to 32 batts, or 2.4% extra.
The coverage figures assume standard 16-inch or 24-inch on-center framing and the listed product. Unfaced batts and different brands vary by a square foot or two per batt, so check the labeled square footage per package if your count comes out close to a whole pallet.
Worked example: a 1,000 sq ft attic
A 40 × 25 ft attic floor is 1,000 sq ft. In R-19 batts at 32 sq ft each: 1,000 ÷ 32 = 31.25, so you carry down 32 batts. At the default $25 per batt the bill is 32 × $25 = $800.00. Switching the same space to R-13 takes 1,000 ÷ 40 = 25 batts for $625, and R-30 takes 1,000 ÷ 25 = 40 batts for $1,000 — deeper insulation costs more both per batt and in count, which is the arithmetic behind every upgrade quote.
Batts needed by coverage
Why coverage differs
R-value measures resistance to heat flow, and fiberglass delivers roughly R-3.2 per inch of thickness. R-13 fills the 3½-inch cavity of a 2×4 wall, R-19 fills the 5½-inch cavity of a 2×6 wall, and R-30 runs about 9–10 inches deep across attic joists. The coverage figure falls as the R-value rises because the same batt width is simply thicker.
| Batt type | Fits | Coverage per batt | Batts for 1,000 sq ft | Cost at $25 |
|---|---|---|---|---|
| R-13 | 2×4 walls | 40 sq ft | 25 | $625 |
| R-19 | 2×6 walls | 32 sq ft | 32 | $800 |
| R-30 | attic joists | 25 sq ft | 40 | $1,000 |
The fitting matters as much as the number: squeezing R-19 into a 2×4 wall compresses it down to roughly R-13, so you pay for glass whose R-value you never receive. Match the batt to the cavity depth instead of forcing the highest R-value into every bay.
What R-value you actually need
- Walls in most climates: R-13 to R-21 — R-13 in 2×4 framing, R-19 to R-21 in 2×6
- Attics in warm climates (zones 1–3): R-30 to R-38
- Attics in mixed climates (zones 4–5): R-38 to R-49
- Attics in cold climates (zones 6–8): R-49 to R-60
- Floors over unheated space: R-19 to R-30
These minimums come from the IECC climate-zone tables, and many states now require R-49 or better in attics on new construction. Upgrading an existing attic from R-19 to R-49 is usually done as a second layer run perpendicular to the joists rather than one thick layer squeezed between them.
Waste, compression and gaps
Batts are forgiving, but two failures are common and both waste money. Compression cuts R-value sharply — a batt compressed to half its thickness loses roughly half its rating, which is what happens when wiring is mashed flat behind it or storage boards are laid on attic insulation. Gaps do worse damage in the other direction: a 5% gap in coverage reduces the effective performance by far more than 5%, because air bypasses the insulation entirely at the gap.
- Cut batts to fit around wiring, boxes and plumbing; do not mash them behind
- Fill small gaps between batts with offcuts rather than leaving bays uncovered
- Face vapor barriers toward the warm side — the interior in heating climates
- In attics, run a second layer perpendicular to the joists and keep soffit vents clear with baffles
2026 insulation prices
Fiberglass batts run $0.50–$1.20 per sq ft of coverage in material. The $25 default expressed that way is $25 ÷ 32 = $0.78 per sq ft for R-19, squarely mid-range. Blown fiberglass runs $0.90–$1.50 per sq ft installed, cellulose $1.00–$1.80, and spray foam $1.50–$3.50 — spray foam costs more per R but seals the air leaks that batts cannot.
| Insulation type | Material per sq ft | Installed per sq ft |
|---|---|---|
| Fiberglass batts | $0.50–$1.20 | $1.00–$2.00 |
| Blown fiberglass | $0.60–$1.00 | $0.90–$1.50 |
| Cellulose (blown) | $0.70–$1.10 | $1.00–$1.80 |
| Spray foam (closed cell) | $1.00–$1.80 | $1.50–$3.50 |
DIY or hire an installer
Batts are the most DIY-friendly insulation there is: no equipment, friction-fit between studs or joists, and the $800 default job is one or two weekends of work for two people. Blown insulation needs a rental blower at $50–$100 a day (often free with a material purchase) and a second person feeding the hopper. Wear gloves, goggles and a respirator either way; fiberglass dust is not dangerous long-term but it is miserable to work in unprotected.
What the calculator leaves out
- Air sealing before insulating, which does more for comfort per dollar than the last R-10
- Kraft facing versus unfaced batts, which changes both price and vapor handling
- Ducts, recessed lights and attic hatches, each of which needs its own treatment
- Framing lumber itself — batts fill cavities, not the studs that divide them
For a mixed climate attic, the practical sequence is: seal penetrations and the hatch, add baffles at the eaves, then layer to the R-value your zone requires. The calculator handles the count; the sequence is what makes the count worth buying.
Frequently asked questions
How many batts do I need for 1,000 sq ft?
25 R-13 batts, 32 R-19 batts or 40 R-30 batts, depending on coverage: 1,000 ÷ 40, ÷ 32 and ÷ 25 respectively, each rounded up.
What R-value should I use in my attic?
R-30 to R-38 in warm climates, R-38 to R-49 in mixed climates and R-49 to R-60 in cold ones. Many states require R-49 or better in attics on new construction.
What is the difference between R-13, R-19 and R-30?
Thickness, mostly. All are fiberglass at about R-3.2 per inch: R-13 fits a 3½-inch 2×4 cavity, R-19 a 5½-inch 2×6 cavity, and R-30 about 9–10 inches across attic joists.
How much does it cost to insulate 1,000 sq ft?
In batts at the defaults, $800 in material (32 R-19 batts at $25). Installed by a contractor expect $1,000–$2,000; blown cellulose lands near $1,000–$1,800.
Can I compress insulation?
No. R-19 squeezed into a 2×4 wall performs at roughly R-13, so you pay for glass whose R-value you never receive. Cut batts to fit instead.
Can I layer batts?
Yes, and it is the standard way to reach R-49 in an attic: run the second layer perpendicular to the joists. Layering adds R-values; compressing subtracts them.
How many batts are in a bag?
Packaging varies by brand, but an R-19 bag commonly holds 8–9 batts, so the default 32-batt job is about four bags. Every package prints its total square footage, which is the number to check.
Does insulation need a vapor barrier?
Kraft-faced batts have one built in, and it goes toward the warm side — the interior in heating climates. Unfaced batts in cold climates usually pair with a separate poly sheet.
Is blown insulation cheaper than batts?
Material cost is similar at $0.60–$1.10 per sq ft, but blown cellulose installs faster over joists and fills gaps better, so for open attics it often wins; batts win in walls between studs.
Method and sources
- Fiberglass batt coverage: R-13 ~40 sq ft, R-19 ~32 sq ft, R-30 ~25 sq ft per batt.