slug: vapor-pressure-calculator
title: "Vapor Pressure Calculator"
category: scientific
updated: 2026-11-18
canonical: https://calcseed.com/c/scientific/vapor-pressure-calculator/
html: /c/scientific/vapor-pressure-calculator/
---

# Vapor Pressure Calculator

Calculate the vapor pressure of a liquid at a new temperature using the Clausius-Clapeyron equation.

## Quick answer

**Quick answer:** with the default inputs (101.33 kPa, 373.15 K, 40,660 J/mol, 363.15 K), the vapor pressure is **70.63**. Change any input to update the result.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Known vapor pressure | 101.325 | kPa |
| Known temperature | 373.15 | K |
| Heat of vaporization | 40660 | J/mol |
| New temperature | 363.15 | K |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Vapor pressure | 70.6284 |  |

## Formula

```text
ln(P_2_ ÷ P_1_) = −(&Delta;H_vap_ ÷ R)(1/T_2_ − 1/T_1_)
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Known vapor pressure | number | kPa | 101.325 |
| Known temperature | number | K | 373.15 |
| Heat of vaporization | number | J/mol | 40660 |
| New temperature | number | K | 363.15 |

## Outputs

| Result | Format |
| --- | --- |
| Vapor pressure | primary |
| Vapor pressure at new temperature | number |

## How it works

### What this calculator returns

The output is the vapour pressure at the new temperature, in the same units as the known pressure you enter. At the defaults — 101.325 kPa at 373.15 K (100&deg;C), &Delta;H_vap_ = 40,660 J/mol and a new temperature of 363.15 K (90&deg;C) — it returns **70.63 kPa**.

That is a 30% drop in pressure for a 10 K drop in temperature, which is the practical message of the whole tool: vapour pressure is steeply sensitive to temperature, and the steepness is set by the heat of vaporization.

### The equation and its terms

P_1_ and P_2_ are the two vapour pressures, T_1_ and T_2_ the matching absolute temperatures in kelvin, &Delta;H_vap_ the molar heat of vaporization in J/mol, and R = 8.314 J/(mol&middot;K). Water&rsquo;s 40,660 J/mol is the energy needed to turn one mole of liquid into vapour at its boiling point.

The form the calculator actually evaluates is P_2_ = P_1_ &middot; exp[−(&Delta;H_vap_÷R)(1/T_2_ − 1/T_1_)]. If T_2_ is below T_1_, the bracket is positive, the exponent is negative and the pressure falls; above T_1_ it rises. The signs take care of themselves, which is why a wrong answer usually means a Celsius temperature crept in.

#### Why the reciprocal temperatures appear

The derivation integrates d(ln P) = (&Delta;H_vap_ ÷ RT²) dT between the two states, and the integral of 1/T² is −1/T. That is where the difference of reciprocals comes from, and it is also why a plot of ln P against 1/T is a straight line whose slope is −&Delta;H_vap_÷R. Two measured points are enough to find the heat of vaporization, which is how the value for a new compound is usually obtained.

### Worked example at the defaults

&Delta;H_vap_ ÷ R = 40,660 ÷ 8.314 = 4,890.6 K. Reciprocal temperatures: 1 ÷ 363.15 = 0.0027537 K^−1 and 1 ÷ 373.15 = 0.0026799, a difference of 0.0000738. Multiply: 4,890.6 × 0.0000738 = 0.3608. Then exp(−0.3608) = 0.6972, and 101.325 × 0.6972 = **70.63 kPa**.

Read the result as a boiling point. Water boils where its vapour pressure equals the surrounding pressure, so 70.63 kPa corresponds to a boiling point of 90&deg;C. That is roughly the pressure at 3,000 m of altitude, and the reason a pot of water there cooks food about 25% slower.

### Water vapour pressure from 70 to 120&deg;C

| Temperature | Kelvin | Vapour pressure |
| --- | --- | --- |
| 70&deg;C | 343.15 K | 32.2 kPa |
| 80&deg;C | 353.15 K | 48.2 kPa |
| 90&deg;C | 363.15 K | 70.6 kPa |
| 100&deg;C | 373.15 K | 101.3 kPa |
| 120&deg;C | 393.15 K | 197.4 kPa |

Every 10 K step multiplies the pressure by roughly 1.5 below 100&deg;C and by about 1.9 above it, which is why pressure cookers reach 120&deg;C at 197 kPa and cut cooking times for beans and stews by two thirds. The curve is exponential, not linear, so interpolating between rows gives the wrong answer outside a narrow band.

### What moves the number

- Heat of vaporization: raising &Delta;H_vap_ from 40,660 to 44,000 J/mol lowers the 90&deg;C result to 68.6 kPa, because the liquid holds its molecules more tightly.
- New temperature: 80&deg;C instead of 90&deg;C drops the answer from 70.6 to 48.2 kPa.
- Reference point: an error of 1 K in T_1_ shifts P_2_ by about 3.5% at these conditions.
- Molar basis: using 2,260 J/mol (the per-gram value) instead of 40,660 produces a pressure barely above the reference.

#### Boiling point and altitude

At sea level the atmosphere pushes 101.3 kPa and water boils at 100&deg;C. At 2,000 m the pressure is near 79.5 kPa and the boiling point falls to roughly 93&deg;C; at 3,000 m, 70.6 kPa gives 90&deg;C. The same arithmetic explains why a vacuum pump can boil water at room temperature: drop the pressure to 2.3 kPa and 20&deg;C water is already at its boiling point.

### Mistakes that break the calculation

- Entering Celsius. The equation needs kelvin, and 90 instead of 363.15 produces a nonsensical exponent.
- Flipping the temperature difference, which inverts the ratio and reports 145 kPa instead of 70.6.
- Mixing kJ/mol with J/mol, a factor of 1,000 that drives the result to either the reference pressure or near zero.
- Treating &Delta;H_vap_ as constant over hundreds of kelvin. It falls as the critical point approaches, so the two-point form is unreliable across a wide range.

The constant-&Delta;H assumption is the one worth respecting. Between 70&deg;C and 120&deg;C water&rsquo;s heat of vaporization drops from about 42.4 to 39.7 kJ/mol, which is why the equation&rsquo;s 197 kPa at 120&deg;C sits just below the measured 198.5 kPa. Over a 200 K span the error grows to double digits.

### Where the result is used

Distillation columns set their operating pressure from this curve, so a vacuum column can separate heat-sensitive compounds at 60&deg;C instead of 140&deg;C. Humidity calculations need the saturation vapour pressure at the current temperature, and engine intake models need it to predict fuel vaporization.

For the gas-phase behaviour once the vapour has formed, the ideal gas law calculator takes over with the partial pressure you just found.

## FAQ

### What is the Clausius-Clapeyron equation?

ln(P2/P1) = −(&Delta;Hvap/R)(1/T2 − 1/T1). For water going from 100&deg;C to 90&deg;C it returns 70.63 kPa from a 101.325 kPa reference.

### Why does vapour pressure rise with temperature?

More molecules have enough thermal energy to escape the liquid. The rise is exponential, roughly 1.5-fold per 10 K near 90&deg;C: 48.2 kPa at 80&deg;C becomes 70.6 at 90&deg;C.

### When does a liquid boil?

When its vapour pressure equals the external pressure. At 70.63 kPa water boils at 90&deg;C, and at sea level where the pressure is 101.3 kPa it boils at 100&deg;C.

### Why does water boil at a lower temperature at altitude?

The atmosphere pushes less. At 3,000 m the pressure is about 70.6 kPa, so water boils at 90&deg;C; at 2,000 m and 79.5 kPa it boils near 93&deg;C.

### What numbers do I enter for water?

Use 101.325 kPa at 373.15 K, &Delta;Hvap = 40,660 J/mol, and the new temperature in kelvin. A 363.15 K target gives 70.63 kPa, which is 30% lower than the reference.

### Can I use Celsius in the formula?

No. The reciprocals require absolute temperature; 90 instead of 363.15 makes the exponent about 4,900 times too large and the result meaningless.

### What happens in a pressure cooker?

Raising the pressure to 197 kPa lifts the boiling point to 120&deg;C, so food cooks faster. That is the same table row read in reverse.

### Is the heat of vaporization constant?

No. Water falls from 42.4 kJ/mol at 70&deg;C to 39.7 kJ/mol at 120&deg;C, so the equation drifts slightly: it predicts 197.4 kPa at 120&deg;C against a measured 198.5 kPa.

### Why is my answer inverted?

You subtracted the temperatures the other way round. Reversing 1/T2 − 1/T1 turns 70.6 kPa into 145 kPa, roughly the pressure at 110&deg;C instead of 90&deg;C.

### What unit should the pressure be in?

Any consistent unit. The equation uses a ratio, so 101.325 kPa, 1 atm or 760 mmHg all give 70.63 when the temperature inputs are correct.

## Method and sources

Methodology: Physical constants follow CODATA 2022 recommended values, and formulas follow standard physics definitions.

Last updated: 2026-11-18.
- Clausius-Clapeyron equation ln(P2/P1) = −(ΔHvap/R)(1/T2 − 1/T1); R = 8.314 J/(mol·K).