# Titration Calculator

Find an unknown concentration from titration volumes, titrant concentration and the reaction mole ratio. Free and instant.

## Quick answer

**Quick answer:** with the default inputs (0.1 M, 25 mL, 25 mL, 1to1), the unknown concentration is **0.1**. Change any input to update the result.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Titrant concentration | 0.1 | M |
| Titrant volume | 25 | mL |
| Analyte volume | 25 | mL |
| Mole ratio (titrant : analyte) | 1to1 |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Unknown concentration | 0.1 |  |

## Formula

```text
C_a_ = C_t_V_t_ × a ÷ (V_a_ × t)
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Titrant concentration | number | M | 0.1 |
| Titrant volume | number | mL | 25 |
| Analyte volume | number | mL | 25 |
| Mole ratio (titrant : analyte) | select |  | 1to1 |

## Outputs

| Result | Format |
| --- | --- |
| Unknown concentration | primary |
| Unknown concentration | number |

## How it works

### What a titration calculation does

A titration delivers a solution of known concentration until the reaction with the unknown is exactly complete, then uses the volume consumed to back out the unknown concentration. This calculator takes the titrant concentration and volume, the analyte volume and the reaction ratio, and returns the analyte concentration in moles per litre.

C_t_ and V_t_ are the titrant concentration and the volume delivered at the endpoint. V_a_ is the measured volume of analyte. The letters a and t are the stoichiometric coefficients from the balanced equation, with a belonging to the analyte and t to the titrant.

That ratio is the entire subtlety. C_t_V_t_ gives moles of titrant, and dividing by t converts them into reaction equivalents; multiplying by a converts equivalents into moles of analyte. Skip the correction and a 1:2 reaction reads half its true concentration.

### Worked example at the defaults

The defaults are 0.1 M titrant, 25 mL delivered, 25 mL of analyte and a 1:1 ratio. The titrant moles are 0.1 × 0.025 = 0.0025 mol, or 2.5 mmol, and with a 1:1 ratio the analyte holds the same 2.5 mmol in 25 mL, giving **0.1000 M**.

The volume units cancel as long as both volumes use the same one. Working in millilitres turns molarity × millilitres into millimoles directly, which is why bench calculations rarely bother converting to litres: 0.1 M × 25 mL = 2.5 mmol every time.

Now the realistic version. If the endpoint actually came at 24.85 mL rather than 25.00 mL, the answer becomes 0.1 × 24.85 ÷ 25 = **0.0994 M**. That 0.6% difference is the kind of gap that separates a passing assay from a failing one when the specification is 99.0–101.0%.

### What the mole ratio does to the answer

| Ratio (titrant : analyte) | Multiplier on the result | Answer at the defaults |
| --- | --- | --- |
| 1 : 1 | ×1 | 0.100 M |
| 1 : 2 | ×2 | 0.200 M |
| 2 : 1 | ×0.5 | 0.050 M |

A 1:2 ratio means one mole of titrant reacts with two moles of analyte, so the same 25 mL of titrant implies twice the analyte concentration. Sulfuric acid against sodium hydroxide is the standard case: H_2_SO_4_ + 2NaOH, so titrating the acid with base needs a 2:1 base-to-acid ratio, and the acid comes out at half the naive value.

Getting this wrong is a factor-of-two error, not a rounding issue, and it is invisible in the arithmetic. Always write the balanced equation before choosing a ratio, even for a familiar titration you have run a hundred times.

### Common titrations and their ratios

- HCl with NaOH: HCl + NaOH &rarr; NaCl + H_2_O, a 1:1 ratio.
- H_2_SO_4_ with NaOH: H_2_SO_4_ + 2NaOH &rarr; Na_2_SO_4_ + 2H_2_O, a 2:1 ratio.
- Na_2_CO_3_ with HCl: Na_2_CO_3_ + 2HCl &rarr; 2NaCl + H_2_O + CO_2_, a 2:1 ratio.
- Potassium hydrogen phthalate with NaOH: KHP + NaOH &rarr; NaKP + H_2_O, a 1:1 ratio, which is why KHP is the standard for calibrating base.
- CaCO_3_ with HCl: CaCO_3_ + 2HCl &rarr; CaCl_2_ + H_2_O + CO_2_, a 2:1 ratio.

Note the direction convention. The list gives titrant first, so adding HCl from the burette to a carbonate sample needs 2:1, and the carbonate concentration comes out at half the HCl concentration. If you titrate in the other direction the ratio inverts, which is why the input is labelled titrant to analyte rather than acid to base.

### Picking an indicator that ends in the right place

The indicator has to change colour where the equivalence point actually falls, and that position depends on the acid and base strengths, not on the ratio. A strong acid with a strong base lands at pH 7, a weak acid with a strong base lands above 8, and a strong acid with a weak base lands below 5.

| System | Indicator | Colour change | Working range |
| --- | --- | --- | --- |
| Strong acid with strong base | Bromothymol blue | yellow to blue | pH 6.0–7.6 |
| Weak acid with strong base | Phenolphthalein | colourless to pink | pH 8.2–10.0 |
| Strong acid with weak base | Methyl orange | red to yellow | pH 3.1–4.4 |
| Weak acid with weak base | None is sharp | no usable endpoint | — |

The last row is not a limitation of the calculator but of the chemistry. When both partners are weak, the pH curve has no steep section and no indicator can locate the equivalence point to better than several percent. Potentiometric titration with a glass electrode is the only practical route.

### Sources of error worth blaming

- Overshooting the endpoint: one extra drop from a 50 mL burette is about 0.05 mL, which is 0.2% of a 25 mL titre and 1% of a 5 mL one.
- Parallax on the burette scale: reading at an angle shifts the meniscus by up to 0.05 mL, the same size as the whole delivery of one drop.
- Rinsing with water instead of titrant: residual water in the burette dilutes the first few millilitres and biases the titre upward.
- Carbon dioxide uptake: a NaOH titrant left open to air absorbs CO_2_ and loses about 1% of its strength per week, which is why it is standardised before use.
- Reading the bottom of the meniscus when the glassware is calibrated to the top, which is a consistent 0.02–0.03 mL offset.
- Using the nominal titre rather than the blank-corrected one: a blank of 0.1 mL on a 5 mL titre is a 2% error.

#### Precision of a burette reading

A class A 50 mL burette is graduated to 0.1 mL and read by interpolation to 0.02 mL. Two readings per titration combine to about &plusmn;0.03 mL, which on a 25 mL delivery is 0.12%. That sets the practical floor on a single manual titration, and it is why duplicate titres within 0.05 mL are considered acceptable.

#### When the sample will not titrate directly

Some analytes react too slowly or too weakly for a direct titration, so a known excess of reagent is added, allowed to react, and the leftover is titrated back. The calculation is a subtraction: moles consumed by the sample equal moles added minus moles found. With 50.00 mL of 0.1000 M reagent and a back-titration of 12.40 mL of 0.0950 M, the sample consumed 5.000 − 1.178 = 3.822 mmol.

## FAQ

### What is the titration formula?

C_a_ = C_t_V_t_a ÷ (V_a_t), where a and t are the analyte and titrant coefficients from the balanced equation. At 0.1 M and 25 mL into 25 mL with a 1:1 ratio the answer is 0.100 M.

### Why does the mole ratio matter?

One mole of titrant does not always consume one mole of analyte. Titrating H_2_SO_4_ with NaOH needs a 2:1 base-to-acid ratio, and ignoring it doubles the reported acid concentration.

### What is the equivalence point?

The point where the titrant has reacted with exactly all the analyte, stoichiometrically. It is not necessarily pH 7: a weak acid with a strong base lands near pH 8.7.

### How accurate is a manual titration?

About 0.1–0.2% on a 25 mL titre, set by reading two burette marks to 0.02 mL each. Short titres of 5 mL drop to 0.5–1%.

### How much does one extra drop change the answer?

A drop is about 0.05 mL. On a 25 mL titre at 0.1 M that moves 0.1000 M to 0.1002 M, only 0.2%.

### Which indicator should I use for HCl and NaOH?

Bromothymol blue, which spans pH 6.0–7.6 around the pH 7 equivalence point. Phenolphthalein also works but changes at 8.2, later than the true endpoint.

### Why is my calculated concentration 0.0994 M instead of 0.1 M?

The endpoint landed at 24.85 mL rather than 25.00 mL. That 0.6% shortfall is normal titration variance and sits inside a typical 99–101% specification.

### What is a back titration?

Adding a known excess of reagent, letting it react, then titrating the remainder. If 50.00 mL of 0.1000 M is added and 12.40 mL of 0.0950 M comes back, the sample consumed 3.82 mmol.

### Does temperature affect the result?

Yes. A 10 &deg;C rise expands the solution by about 0.2%, and the titrant concentration defined at 20 &deg;C is no longer exact at 30 &deg;C.

## Method and sources

Methodology: Physical constants follow CODATA 2022 recommended values, and formulas follow standard physics definitions.

Last updated: 2026-11-17.
- Titration calculation: unknown concentration from titrant concentration, volumes and stoichiometric ratio.