# Thermal Resistance Converter

Convert thermal resistance between K/W, °C/W and °F·h/BTU.

## Quick answer

**Thermal Resistance Converter** — convert between K/W, °C/W, °F·h/BTU and more.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Value | 1 |  |
| From | K/W |  |
| To | Fh/BTU |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Result | 0.527528 |  |

## Formula

```text
R = &Delta;T ÷ Q, and result = value × factor(from) ÷ factor(to) with factors 1 K/W, 1 &deg;C/W, 1.895634 &deg;F&middot;h/BTU
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Value | number |  | 1 |
| From | select |  | K/W |
| To | select |  | Fh/BTU |

## Outputs

| Result | Format |
| --- | --- |
| Result | primary |
| Result | unit |

## How it works

### What this converter returns

Thermal resistance is the temperature rise a component suffers for every watt it dissipates. This page converts between K/W, &deg;C/W and &deg;F&middot;h/BTU. At the defaults it turns **1 K/W** into **0.5275 &deg;F&middot;h/BTU**, the same heatsink rated in US customary units.

The first two units are the same size, because thermal resistance uses a temperature difference and a kelvin step equals a Celsius step. The third is the imperial equivalent, larger because an hour-long BTU carries more energy than a joule and a Fahrenheit degree is only five ninths of a kelvin.

### The conversion rule

The definition behind every unit is R = &Delta;T ÷ Q: the temperature difference across a path divided by the heat flowing through it. A heatsink at 0.5 &deg;C/W carrying 40 W therefore sits 20 K above ambient. The unit is a ratio of a temperature to a power, which is why no length or area appears in it.

The imperial factor is built from four definitions at once. One Fahrenheit degree is 5/9 K, one hour is 3,600 s and one BTU is 1,055.05585262 J. So 1 &deg;F&middot;h/BTU = (5/9 × 3,600) ÷ 1,055.05585262 = **1.895634 K/W**. Inverting gives 1 K/W = 0.5275 &deg;F&middot;h/BTU.

#### Why &deg;C/W and K/W are identical

A kelvin and a Celsius degree are the same size, and the conversion only ever uses differences. A 30 K rise equals a 30 &deg;C rise, so 1 K/W and 1 &deg;C/W describe exactly the same performance. The labels differ by convention: semiconductor data sheets use &deg;C/W, physics texts use K/W.

### Worked example at the defaults

Convert 1 K/W to imperial units. The from-factor is 1 and the to-factor is 1.895634, so 1 ÷ 1.895634 = **0.5275 &deg;F&middot;h/BTU**. Read the other way, an old heat sink catalogue listing 2 &deg;F&middot;h/BTU is 2 × 1.895634 = 3.79 K/W, a fairly weak sink.

Put those numbers to work. A 65 W processor behind a 0.25 &deg;C/W cooler rises 16.3 K above the case, so a 35 &deg;C case gives a 51 &deg;C junction. The same sink in imperial units is 0.474 &deg;F&middot;h/BTU, and the 16.3 K rise is 29.3 &deg;F.

| Unit | In K/W | One K/W equals |
| --- | --- | --- |
| K/W | 1 | 1 K/W |
| &deg;C/W | 1 | 1 &deg;C/W |
| &deg;F&middot;h/BTU | 1.895634 | 0.5275 &deg;F&middot;h/BTU |

### Typical thermal resistances

These are junction-to-ambient or junction-to-case figures for parts you can buy. They are useful as a check: a claimed 0.05 &deg;C/W air-cooled sink is a laboratory curiosity, not a catalogue item.

| Path | K/W | &deg;F&middot;h/BTU |
| --- | --- | --- |
| TO-220 junction to case | 1.5–4 | 2.84–7.58 |
| Small extruded sink, natural convection | 3–8 | 5.7–15.2 |
| Tower cooler with fan | 0.1–0.3 | 0.19–0.57 |
| Thermal paste joint, 1 cm² | 0.1–0.5 | 0.19–0.95 |
| Direct-die liquid cold plate | 0.03–0.08 | 0.06–0.15 |

Resistances in series add, which is the whole point of the unit. A 65 W load with 0.25 &deg;C/W junction-to-case, 0.1 &deg;C/W of paste and 0.3 &deg;C/W of sink totals 0.65 &deg;C/W, so the junction runs 42 K above ambient rather than the 16 K the sink alone would suggest.

#### Absolute versus per-area resistance

Building insulation quotes R in m²&middot;K/W, which includes an area and is a different quantity from K/W. A wall at 2.5 m²&middot;K/W has no single K/W value until you know its area: at 10 m² it is 0.25 K/W. The US equivalent, ft²&middot;h&middot;&deg;F/BTU, equals 0.1761 m²&middot;K/W, and the familiar R-13 is 2.29 m²&middot;K/W. Do not mix those figures with the heat-sink numbers in this tool.

### Where a wrong rating burns a part

- Forgetting the interface. Leaving out 0.1 &deg;C/W of paste on a 65 W part adds 6.5 K to the junction temperature.
- Treating &deg;F&middot;h/BTU as if it were smaller than K/W. It is 1.9 times larger, so a 2 &deg;F&middot;h/BTU sink is 3.8 K/W, not 1.1 K/W.
- Quoting natural-convection ratings with a fan installed, or the reverse. Airflow can cut resistance by a factor of three.
- Ignoring that datasheet R_jc_ assumes a specified case temperature measurement point.

The first two account for most field failures in power electronics. A part with a 150 &deg;C junction limit, a 50 &deg;C ambient and 100 W needs a total path below 1.0 &deg;C/W; anything above that derates the part or trips its protection.

### Common mistakes

- Adding resistances that are measured at different airflow conditions.
- Assuming R doubles when power halves. It does not: the ratio &Delta;T ÷ Q is a property of the path, not of the load.
- Reading a &deg;C/W figure as a temperature. It is a rise per watt, so 0.5 &deg;C/W says nothing without the wattage.
- Using the same R for steady state and for a 10 ms pulse, where thermal capacitance dominates.

The last point separates two design tasks. Steady-state sizing uses the resistance alone; a pulse rating needs the transient thermal impedance curve, which starts far below the steady value and climbs toward it over seconds.

### Precision and rounding

The imperial factor is exact to the definitions of the degree, hour and BTU and is quoted here to seven figures. Heatsink measurements are usually good to 10 percent, and natural-convection figures depend on orientation, so two significant figures are enough: 0.25 &deg;C/W, 3.8 K/W, 0.53 &deg;F&middot;h/BTU.

## FAQ

### How do I convert &deg;C/W to K/W?

One to one. A kelvin and a Celsius degree are the same size and thermal resistance uses a difference, so 2.5 &deg;C/W is 2.5 K/W.

### How many K/W are in 1 &deg;F&middot;h/BTU?

1.895634 K/W. A heat sink rated 2 &deg;F&middot;h/BTU is therefore 3.79 K/W, which is a modest natural-convection sink.

### Is 0.5 &deg;C/W a good heat sink?

It is respectable for a fan-cooled sink. At 40 W it holds the case 20 K above ambient; at 100 W it holds 50 K, which usually needs a bigger sink.

### How do I size a heat sink for a 100 W part?

Use R = (T_j_ − T_a_) ÷ P minus the junction-to-case and interface terms. With 150 &deg;C allowed, 50 &deg;C ambient, 0.3 &deg;C/W junction-to-case and 0.1 &deg;C/W of paste, the sink must be 0.6 &deg;C/W or better.

### Why is &deg;F&middot;h/BTU larger than K/W?

Because a Fahrenheit degree is 5/9 of a kelvin while an hour-long BTU is 1,055 J. The two effects combine to 1.895634, so imperial ratings look smaller for the same performance.

### Is thermal resistance the same as R-value?

No. R-value includes an area, in m²&middot;K/W or ft²&middot;h&middot;&deg;F/BTU. R-13 is 2.29 m²&middot;K/W, which is a different unit from the K/W used for heat sinks.

### Do thermal resistances add?

Yes, in series. Junction-to-case, interface and sink resistances sum, so 0.25 + 0.1 + 0.3 gives 0.65 &deg;C/W for the whole path.

### How much does thermal paste contribute?

Typically 0.1–0.5 K/W per square centimetre of joint. On a 65 W part that is 6.5–32 K of the total rise, so a dry joint is never acceptable.

### Can I use a steady-state rating for a short pulse?

No. For pulses under a second the thermal capacitance dominates and the effective impedance is far below the steady rating, so you need the transient curve.

### How accurate is the conversion?

The factor is exact to seven figures. Measurement tolerance of 10 percent on the sink dominates, so report two significant figures such as 0.25 &deg;C/W.

## Method and sources

Methodology: Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: 2026-11-19.
- Linear conversion through K/W: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 °C/W = 1 K/W; 1 °F·h/BTU = 1.895634 K/W.
- Degrees Celsius per watt is exactly 1 K/W, since the interval is the same. Degrees Fahrenheit-hour per BTU is 3600 times 5/9 divided by the International Table BTU (1055.05585262 J), stored rounded.
- The SI prefixes are exact; the °F·h/BTU factor is stored as a rounded decimal, the largest deviation being 1.3e−5% relative. A result carries that rounding on top of floating-point arithmetic.