# Thermal Diffusivity Converter

Convert thermal diffusivity between m²/s, cm²/s and mm²/s.

## Quick answer

**Thermal Diffusivity Converter** — convert between m²/s, cm²/s, mm²/s and more.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Value | 0.143 |  |
| From | mm2/s |  |
| To | m2/s |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Result | 1.43e-7 |  |

## Formula

```text
&alpha; = k ÷ (&rho; c_p_), and result = value × factor(from) ÷ factor(to) with factors 1 m²/s, 0.0001 cm²/s, 0.000001 mm²/s, 0.09290304 ft²/s
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Value | number |  | 0.143 |
| From | select |  | mm2/s |
| To | select |  | m2/s |

## Outputs

| Result | Format |
| --- | --- |
| Result | primary |
| Result | unit |

## How it works

### What this converter returns

Thermal diffusivity measures how fast a temperature change spreads through a material. It is the ratio of how well a material conducts heat to how much heat it stores per unit volume, and it carries units of area per second. This page converts between m²/s, cm²/s, mm²/s and ft²/s. At the defaults it turns **0.143 mm²/s** into **1.43 × 10^−7 m²/s**, the diffusivity of water at room temperature.

The unit is unusual because it contains area rather than length. That is deliberate: diffusivity has the dimensions of length squared per time, so the natural measure of how far heat has travelled is the square root of diffusivity times time. A material with double the diffusivity carries a temperature front only 1.41 times further in the same period.

### The conversion rule

Diffusivity is conductivity divided by volumetric heat capacity: &alpha; = k ÷ (&rho;c_p_). A material that conducts well and stores little spreads heat quickly, which is why copper leads the table. Water conducts poorly but stores a great deal, so it trails far behind despite being a liquid.

The metric factors are exact squares of the length prefixes: 1 cm² is 10^−4 m², so 1 cm²/s is 10^−4 m²/s, and 1 mm²/s is **10^−6 m²/s**. The imperial factor is the square of 0.3048, giving 1 ft²/s = 0.09290304 m²/s, which is enormous compared with the others and rarely used outside very large-scale geophysical work.

#### Diffusivity versus conductivity

Conductivity says how much heat flows for a given gradient. Diffusivity says how quickly the gradient itself moves. Insulation foam has low conductivity and low diffusivity; copper has high conductivity and high diffusivity; water has low conductivity but moderate diffusivity because its volumetric heat capacity, 4.18 MJ/(m³&middot;K), is large. A material can therefore be a poor conductor and still respond quickly if it stores little heat.

### Worked example at the defaults

Convert 0.143 mm²/s to m²/s. Multiplying by 0.000001 gives **1.43 × 10^−7 m²/s**. The same value is 0.00143 cm²/s and 1.54 × 10^−6 ft²/s.

Use the number to estimate a diffusion time. The characteristic time is L² ÷ &alpha;, so a 1 cm layer of water takes 10^−4 ÷ 1.43 × 10^−7 = **699 s**, about 12 minutes. The same 1 cm of steel at 1.2 × 10^−5 m²/s takes only 8.3 s, and 1 cm of copper at 1.11 × 10^−4 takes 0.9 s.

| Unit | In m²/s | One m²/s equals |
| --- | --- | --- |
| m²/s | 1 | 1 m²/s |
| cm²/s | 0.0001 | 10,000 cm²/s |
| mm²/s | 0.000001 | 1,000,000 mm²/s |
| ft²/s | 0.09290304 | 10.7639 ft²/s |

### Diffusivity of common materials

The table lists room-temperature values, computed from conductivity, density and specific heat. Metals span two orders of magnitude and non-metals three, so the choice of material dominates any transient thermal design before geometry is considered.

| Material | mm²/s | m²/s | 1 cm diffusion time |
| --- | --- | --- | --- |
| Copper | 111 | 1.11 × 10^−4 | 0.9 s |
| Aluminium | 97 | 9.7 × 10^−5 | 1.0 s |
| Air at 20 &deg;C | 21 | 2.1 × 10^−5 | 4.8 s |
| Carbon steel | 12 | 1.2 × 10^−5 | 8.3 s |
| Water at 20 &deg;C | 0.143 | 1.43 × 10^−7 | 699 s |
| Concrete | 0.6 | 6 × 10^−7 | 167 s |
| Softwood | 0.15 | 1.5 × 10^−7 | 667 s |

Air sits above steel because its volumetric heat capacity is tiny, only about 1.2 kJ/(m³&middot;K), even though it conducts heat poorly. That is why a room warms quickly when the radiator comes on but a steel block takes minutes: the air carries little energy and needs very little to change temperature.

#### Where the diffusion length matters

The diffusion length &radic;(&alpha;t) sets the depth a surface temperature swing penetrates. A daily cycle of 86,400 s penetrates concrete by &radic;(6 × 10^−7 × 86,400) = 0.23 m, while copper reaches 3.1 m in the same period. Seasonal swings in soil reach about 3 m, which is why buried pipes at that depth see a nearly constant temperature.

### Where the conversion goes wrong

- Confusing cm²/s with mm²/s. The factor between them is 100, not 10, because the prefix is squared.
- Treating diffusivity as conductivity. Two materials with the same conductivity can differ by a factor of four in diffusivity if their heat capacities differ.
- Using a steady-state value for a transient problem, where the diffusion length rather than the resistance controls the answer.
- Forgetting that diffusivity of a porous material depends on moisture, which can raise it by 50 percent.

The first item is the most common arithmetic slip. Because area scales with the square of length, moving from millimetres to centimetres multiplies by 100 and from centimetres to metres by 10,000. A value of 12 mm²/s is 0.12 cm²/s, not 1.2 cm²/s.

### Common mistakes

- Quoting diffusivity without a temperature. Water changes little, but air and steel both shift several percent between 0 and 100 &deg;C.
- Applying a room-temperature value to a cryogenic design, where copper improves by a factor of ten.
- Assuming a composite has the arithmetic mean of its phases. Layered materials diffuse mostly along the high-diffusivity direction.
- Using ft²/h instead of ft²/s, which differs by a factor of 3,600.

The last one appears in older US civil engineering references, where soil diffusivity is quoted in ft²/h. A value of 0.02 ft²/h is 5.6 × 10^−7 m²/s, and reading it as per second would overstate the value by three and a half orders of magnitude.

### Precision and rounding

The metric factors are exact squares of exact prefixes and the imperial factor is the exact square of 0.3048, so no rounding enters the conversion. Measured diffusivity carries 5 to 15 percent uncertainty because it depends on three measured properties. Two significant figures are enough: 1.4 × 10^−7 m²/s, 12 mm²/s, 111 mm²/s.

## FAQ

### How do I convert mm&sup2;/s to m&sup2;/s?

Multiply by 0.000001. A value of 0.143 mm²/s is 1.43 × 10^−7 m²/s, the diffusivity of water.

### How many mm&sup2;/s are in 1 cm&sup2;/s?

100. The prefix is squared, so a centimetre squared holds one hundred millimetres squared, not ten.

### What is the thermal diffusivity of copper?

About 1.11 × 10^−4 m²/s, or 111 mm²/s. A 1 cm layer responds in roughly 0.9 s.

### Why is air more diffusive than steel?

Because its volumetric heat capacity is only about 1.2 kJ/(m³&middot;K). Low storage outweighs low conductivity, giving 21 mm²/s against 12 mm²/s for steel.

### How do I estimate how long heat takes to cross a layer?

Use L² ÷ &alpha;. One centimetre of water at 1.43 × 10^−7 m²/s takes 699 s, and the same thickness of steel takes 8.3 s.

### Is thermal diffusivity the same as thermal conductivity?

No. Conductivity is W/(m&middot;K), diffusivity is m²/s, and they are linked by density and specific heat: &alpha; = k ÷ (&rho;c_p_).

### How deep does a daily temperature swing reach?

About &radic;(&alpha; × 86,400). For concrete that is 0.23 m, and for copper 3.1 m, which is why the ground a few metres down stays near constant.

### How many ft&sup2;/s is 1 m&sup2;/s?

10.7639. One square foot is 0.09290304 m², so the reciprocal gives the factor in the other direction.

### Does moisture change diffusivity?

Yes, substantially. Water in pores raises the volumetric heat capacity and the conductivity together, often lifting diffusivity by 20 to 50 percent in soil and concrete.

### How accurate is the conversion?

The factors are exact. Measured values carry 5 to 15 percent uncertainty, so two significant figures are appropriate for any reported diffusivity.

## Method and sources

Methodology: Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: 2026-11-19.
- Linear conversion through m²/s: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 cm²/s = 0.0001 m²/s; 1 mm²/s = 0.000001 m²/s; 1 ft²/s = 0.09290304 m²/s.
- Every factor is exact: the centimetre and millimetre are powers of ten, and 1 ft²/s = 0.09290304 m²/s from the international foot.
- Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.