slug: sump-pump-size-calculator
title: "Sump Pump Size Calculator"
category: home
updated: 2026-11-17
canonical: https://calcseed.com/c/home/sump-pump-size-calculator/
html: /c/home/sump-pump-size-calculator/
---

# Sump Pump Size Calculator

Estimate the sump pump flow rate (GPH) needed for a drainage area and rainfall intensity.

## Quick answer

**Quick answer:** with the default inputs (1,000 sq ft, 1 in/hr), the required flow is **623**. At these inputs: recommended pump = **934.5**. Change any input to update the result.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Drainage area | 1000 | sq ft |
| Rainfall intensity | 1 | in/hr |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Required flow | 623 |  |
| Recommended pump | 934.5 |  |

## Formula

```text
flow = area × rainfall × 0.623
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Drainage area | number | sq ft | 1000 |
| Rainfall intensity | number | in/hr | 1 |

## Outputs

| Result | Format |
| --- | --- |
| Required flow | primary |
| Required flow | unit |
| Recommended pump | unit |

## How it works

### What this calculator returns

Enter the footprint that drains toward the pit and the rainfall intensity you want to survive. The tool returns **gallons per hour of inflow** and a **recommended pump rating** at 1.5 times that flow. At the defaults — 1,000 sq ft under a 1 in/hr storm — the inflow is 623 GPH, or 10.4 gallons a minute, and the target pump rating is 934 GPH.

### The inflow formula

**A** is the area in square feet that actually sends water to the pit, **r** is the storm intensity in inches per hour, and 0.623 is the gallons in one square foot of water one inch deep. The 1.5 multiplier is a safety factor, not part of the hydrology: a pump sized exactly to the inflow never gets ahead of the water, so it runs continuously and loses.

#### Why 0.623 and why 1.5

One inch over one square foot is 1 ÷ 12 = 0.0833 cubic feet, and a cubic foot holds 7.48 gallons, so 0.0833 × 7.48 = 0.623 gallons. The 1.5 factor covers surge at the start of a storm, a partially blocked inlet grate and the fact that pump ratings are measured at zero head while yours will be lifting water 8–12 ft.

Keep the drainage area honest. A 1,000 sq ft roof plus a 400 sq ft driveway sloping to the same corner is 1,400 sq ft of contributory area. Include patios and lawn that visibly sheets toward the foundation.

### Worked example at the defaults

1,000 sq ft × 1 in/hr × 0.623 = **623 GPH**, or 10.4 GPM. Multiply by the 1.5 safety factor and the pump target is **934 GPH**, which any 1/3 hp submersible rated 2,400 GPH at zero head will meet on paper.

Now check it against the head. That 1/3 hp pump delivers about 1,900 GPH at 10 ft of total head, still three times the 623 GPH inflow, so the pit empties while the storm continues. Raise the drainage area to 3,000 sq ft and the inflow becomes 1,869 GPH, at which point the same pump at 10 ft head barely keeps up and the target rating of 2,803 GPH calls for a 1/2 hp unit.

The safety factor matters most at the low end. A 500 sq ft area produces only 312 GPH, so a 1/3 hp pump is the floor, the smallest standard unit made.

### Inflow by drainage area and storm intensity

Each cell is area × intensity × 0.623, the same arithmetic the calculator runs. A 1 in/hr storm is a routine spring event in most of the US; a 100-year one-hour intensity is 1.5–3 in/hr across the Midwest and Northeast and 3–4 in/hr on the Gulf Coast.

| Drainage area | 0.5 in/hr | 1 in/hr | 2 in/hr | 3 in/hr |
| --- | --- | --- | --- | --- |
| 500 sq ft | 156 GPH | 312 GPH | 623 GPH | 934 GPH |
| 1,000 sq ft | 312 GPH | 623 GPH | 1,246 GPH | 1,869 GPH |
| 1,500 sq ft | 467 GPH | 934 GPH | 1,869 GPH | 2,803 GPH |
| 2,000 sq ft | 623 GPH | 1,246 GPH | 2,492 GPH | 3,738 GPH |
| 3,000 sq ft | 934 GPH | 1,869 GPH | 3,738 GPH | 5,607 GPH |

Design for the storm you cannot afford to fail, not the average one. Sizing 1,000 sq ft to 1 in/hr gives 623 GPH; sizing the same area to 2 in/hr gives 1,246 GPH, double the pump. The cost difference between a 1/3 hp and a 1/2 hp unit is $50–$100, which is less than one flooded basement.

### Head is what turns a rating into reality

Pump curves are published at zero lift. Every foot you raise the discharge, plus friction in the pipe, moves you left along the curve and reduces flow. Total dynamic head is vertical lift from the pit floor to the highest point of the discharge, plus about 1 ft of friction per 10 ft of 1&frac12; in PVC at 30 GPM, plus 1–2 ft for elbows and a check valve.

#### Working out your head

A typical basement: 6 ft of lift, 20 ft of horizontal run to the outside wall, three elbows, so roughly 6 + 2 + 3 = 11 ft of head. At that head a 1/3 hp pump rated 2,900 GPH at zero delivers about 1,800 GPH, a 38% derating. Plan on losing 30–40% of the nameplate rating for any basement installation.

### Picking the pump class

Ratings below are zero-head flows for cast-iron submersible pumps, which is how the box is labelled. Compare against the recommended rating from the calculator, then bump one class if your head exceeds 10 ft.

| Pump size | Flow at 0 ft head | Flow at 10 ft head | Price |
| --- | --- | --- | --- |
| 1/3 hp | 2,400–2,900 GPH | 1,700–1,900 GPH | $150–$250 |
| 1/2 hp | 3,300–3,900 GPH | 2,300–2,700 GPH | $200–$350 |
| 3/4 hp | 4,500–5,000 GPH | 3,200–3,600 GPH | $300–$500 |
| 1 hp | 5,500–6,500 GPH | 4,000–4,700 GPH | $400–$700 |

A cast-iron submersible costs $150–$350 for the pump, and a plumber charges $350–$800 to install it with a new check valve and discharge piping. A battery backup unit adds $350–$700 and is worth it wherever the power fails during the same storm that fills the pit, which is most of the country.

### Pit volume decides how often the pump starts

A correctly sized pump can still destroy itself if the pit is too small, because a tight pit makes it short-cycle. Cycle time = drawdown ÷ (pump flow − inflow) + drawdown ÷ inflow. With 10 gallons of drawdown, 623 GPH (10.4 GPM) of inflow and 1,800 GPH (30 GPM) of pump, that is 10 ÷ 19.6 + 10 ÷ 10.4 = 0.51 + 0.96 = **1.5 minutes per cycle, or 41 starts an hour**.

Motors are built for roughly 6–12 starts an hour. To get to a 5 minute cycle at these flows you need about 34 gallons of drawdown. An 18 in diameter pit 2 ft deep holds 26 gallons in total (3.5 cu ft), so only 16–18 gallons are usable; a 24 in pit 2 ft deep holds 47 gallons and gets you there.

- **18 in pit, 2 ft deep.** 26 gal total, about 22 cycles an hour at the default inflow.
- **24 in pit, 2 ft deep.** 47 gal total, about 12 cycles an hour, the usual minimum for a 1/3 hp pump.
- **30 in pit, 2 ft deep.** 73 gal total, about 8 cycles an hour, comfortable for a 1/2 hp unit.

### Where installations go wrong

- **Sizing the pit to the hole, not the inflow.** A 12 in pit holds 11 gallons total and will short-cycle any pump at any flow.
- **Ignoring the check valve.** Without one, water drains back after every cycle and the pump restarts against a full column, doubling the cycles.
- **Discharging into the footer drain.** The water returns to the pit and the pump runs forever. Run the discharge 6–10 ft from the foundation and slope it away.
- **No backup during outages.** The storms that overwhelm a sump are the ones that take the power out, which is exactly when a battery unit earns its $350–$700.

## FAQ

### What size sump pump do I need for a 2 ft deep pit?

Pit depth sets the cycle volume, not the flow. A 24 in diameter pit 2 ft deep holds 47 gallons and suits a 1/3 hp pump at 623 GPH inflow; an 18 in pit holds 26 gallons and will short-cycle the same pump 22 times an hour.

### How do I calculate sump pump size?

Multiply the drainage area by the rainfall intensity by 0.623 to get gallons per hour, then add 50%. A 1,000 sq ft area under a 1 in/hr storm needs 623 GPH of inflow and a 934 GPH pump rating.

### What rainfall rate should I design for?

One inch per hour is a routine storm; 2 in/hr is a reasonable target for most of the US, and 3 in/hr for the Gulf Coast or a basement with a flooding history. Pump size doubles between 1 and 2 in/hr.

### Does head reduce pump output?

Yes. Ratings are quoted at zero lift, and a 1/3 hp pump rated 2,900 GPH delivers about 1,800 GPH at 10 ft of total head, a 38% loss. Assume 30–40% derating for any basement discharge.

### How many gallons per hour is a 1/3 hp sump pump?

About 2,400 to 2,900 GPH at zero head, falling to 1,700 to 1,900 GPH at 10 ft. A 1/2 hp unit runs 3,300 to 3,900 GPH at zero head.

### How big should my sump pit be?

At least 24 in diameter and 2 ft deep, which holds 47 gallons and gives roughly 30 gallons of drawdown. That keeps a 1/3 hp pump at about 12 starts an hour instead of 41.

### How often should a sump pump cycle?

No more than 6 to 12 times an hour during a storm. Faster cycling points to an oversized pump or an undersized pit, and it burns out the switch first and the motor second.

### Why does my sump pump run constantly?

Usually the discharge is returning to the pit, either because it dumps next to the foundation or because the check valve has failed. A 623 GPH inflow should let a 1/3 hp pump rest most of the time.

### Do I need a battery backup sump pump?

If your area loses power during storms, yes. A backup runs $350 to $700 and covers 6 to 12 hours of pumping, which is the window when a primary pump stops and the pit keeps filling.

### How much does a sump pump installation cost?

The pump is $150 to $350 and installation adds $350 to $800 with a new check valve and discharge line. A pit and liner add $250 to $600, and a battery backup another $350 to $700.

## Method and sources

Methodology: Cost ranges reflect 2026 U.S. national averages for materials and labor; regional pricing varies, so use results as a planning baseline and confirm with local quotes.

Last updated: 2026-11-17.
- 1 inch of rain over 1 sq ft ≈ 0.623 gallons; sump pump sizing with safety factor.