# Specific Gas Constant Converter

Convert specific gas constant between J/(kg·K) and kJ/(kg·K).

## Quick answer

**Specific Gas Constant Converter** — convert between J/(kg·K), kJ/(kg·K) and more.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Value | 287 |  |
| From | J/kgK |  |
| To | kJ/kgK |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Result | 0.287 |  |

## Formula

```text
result = value × factor(from) ÷ factor(to), with 1 J/(kg&middot;K) = 1 and 1 kJ/(kg&middot;K) = 1000 J/(kg&middot;K)
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Value | number |  | 287 |
| From | select |  | J/kgK |
| To | select |  | kJ/kgK |

## Outputs

| Result | Format |
| --- | --- |
| Result | primary |
| Result | unit |

## How it works

### What the specific gas constant measures

The specific gas constant is the ideal-gas constant divided by molar mass, so it applies to one kilogram of a particular gas rather than to one mole of anything. It appears in p = &rho;RT and in every isentropic relation, and its SI unit is the joule per kilogram per kelvin, J/(kg&middot;K).

Dry air is the reference case at 287 J/(kg&middot;K). The universal constant is 8.314462618 J/(mol&middot;K), and dividing by air&rsquo;s molar mass of 0.0289647 kg/mol gives 287.05, which is the value every HVAC and turbomachinery table reproduces.

### The conversion rule

Kilo is exactly 10³, so the only conversion in this tool is a factor of 1,000. A value given per kilogram-kelvin in kilojoules is a thousand times larger numerically than the same value in joules, which is why a table entry of 0.287 belongs to air and an entry of 287 belongs to it too.

Kelvin and Celsius intervals are the same size, so J/(kg&middot;K) and J/(kg&middot;&deg;C) are numerically identical. Only absolute values differ, and the gas constant is always a per-degree quantity, so a table labelled per &deg;C needs no conversion at all.

### Worked example: 287 J/(kg·K)

The defaults take 287 J/(kg&middot;K) and target kJ/(kg&middot;K). Divide by 1000: **0.287 kJ/(kg&middot;K)**. The reverse, 0.287 × 1000 = 287, returns the starting figure.

Check the value from first principles. 8.314462618 ÷ 0.0289647 = 287.05, so the default is the specific constant of dry air to four significant figures. Any combustion or psychrometric calculation that uses 287 is implicitly treating the gas as dry air, which is accurate to about 1 percent below 100 &deg;C.

### Specific gas constants for common gases

| Gas | Molar mass (kg/mol) | R, J/(kg·K) | R, kJ/(kg·K) |
| --- | --- | --- | --- |
| Air | 0.028965 | 287.1 | 0.2871 |
| Nitrogen | 0.028013 | 296.8 | 0.2968 |
| Oxygen | 0.031999 | 259.8 | 0.2598 |
| Carbon dioxide | 0.044010 | 188.9 | 0.1889 |
| Methane | 0.016043 | 518.3 | 0.5183 |
| Hydrogen | 0.002016 | 4124 | 4.124 |
| Helium | 0.004003 | 2077 | 2.077 |

The table spans a factor of 22 between carbon dioxide and hydrogen, which is why a single 287 in a spreadsheet is a silent error for any gas other than air. Hydrogen carries 14 times the gas constant of air, so the same pressure and temperature give a density 14 times lower.

### Where the conversion matters

The gas constant appears in every equation that links pressure, density and temperature, so the unit chosen by the datasheet propagates into the whole calculation.

- Compressor and turbine work, where kJ/(kg&middot;K) matches the shaft power in kW.
- Speed of sound, where a = &radic;(&gamma;RT) needs R in J/(kg&middot;K) to return m/s.
- Psychrometrics, where the dry-air constant 287 sets humidity ratio and enthalpy.
- Leak and flow testing, where density from p = &rho;RT converts a pressure drop into mass flow.

#### Speed of sound check

For air, a = &radic;(&gamma;RT) with &gamma; = 1.4. At 293 K that is &radic;(1.4 × 287 × 293) = &radic;117,700 = 343 m/s, the standard figure quoted at room temperature. Use 1005/718 for &gamma; and the same answer appears, which is a good check that R and the specific heats come from the same source.

### The gap between cp and cv

For an ideal gas, cp − cv = R. Air has cp = 1005 and cv = 718 J/(kg&middot;K), and the difference is 287, exactly the gas constant. That identity ties the three numbers together: if a table lists cp and R, cv follows without a second lookup.

The ratio &gamma; = cp/cv then follows too. Air gives 1005 ÷ 718 = 1.40, carbon dioxide gives 844 ÷ 655 = 1.29, and helium gives 5193 ÷ 3116 = 1.67. Those ratios set the exponent in every isentropic relation, so a wrong R propagates into both the level and the slope of the compression curve.

### Compressor power from the constant

Isentropic compression power is m&#775;cpT&#8321;[(p&#8322;/p&#8321;)^((&gamma;−1)/&gamma;) − 1]. Compressing 1 kg/s of air from 300 K through a pressure ratio of 4 needs 1005 × 300 × (4^0.2857 − 1) = 147 kW. Change the gas to carbon dioxide and both cp and the exponent shift, which is why natural-gas compression is never sized with air&rsquo;s constant.

### Precision and common mistakes

- Using 8.314 in a formula that expects the specific constant, which is out by a factor of 28.97 for air.
- Mixing kJ and J in the same equation, a factor-of-1,000 error that survives because both look plausible.
- Treating 287 as universal for combustion products, where R rises toward 290 as water vapour replaces air.
- Entering a temperature in &deg;C into p = &rho;RT, which requires kelvin.

Moist air needs a small correction. Water vapour has a gas constant of 461.5 J/(kg&middot;K), so humid air sits above 287: at 30 &deg;C and saturation the mixture is about 292 J/(kg&middot;K), roughly 1.7 percent higher. That shift lowers density by the same fraction, which matters in cooling-tower and psychrometric work but is negligible in a low-humidity compressor intake.

#### Density from the constant

At 101,325 Pa and 293 K, air density is 101,325 ÷ (287 × 293) = 1.204 kg/m³. The same expression with hydrogen gives 0.0838 kg/m³, and with carbon dioxide 1.83 kg/m³. Those three numbers explain why a helium balloon lifts and why a CO&#8322; fire extinguisher smothers a fire at floor level.

## FAQ

### How many kJ/(kg·K) is 287 J/(kg·K)?

0.287 kJ/(kg&middot;K). Divide by 1,000, since kilo is 10³. That is the specific gas constant of dry air.

### How many J/(kg·K) is 1 kJ/(kg·K)?

1,000 J/(kg&middot;K). Multiply by 1,000, so a value of 0.189 for carbon dioxide becomes 189 J/(kg&middot;K).

### What is the gas constant of air?

287.05 J/(kg&middot;K), from 8.31446 ÷ 0.028965. Most engineering tables round it to 287, which is accurate to 0.02 percent.

### Why is the gas constant different for each gas?

Because it is the universal constant divided by molar mass. Hydrogen at 2.016 g/mol gets 4,124 J/(kg&middot;K), while carbon dioxide at 44.01 g/mol gets only 188.9.

### Is J/(kg·K) the same as J/(kg·°C)?

Yes, numerically. A kelvin and a Celsius degree are the same size, so only absolute temperatures differ, and the constant is a per-degree quantity.

### How do I find cv if I know R and cp?

Subtract: cv = cp − R. For air that is 1005 − 287 = 718 J/(kg&middot;K), which gives &gamma; = 1.40.

### What is the density of air at 20 °C?

1.204 kg/m³ at 101,325 Pa, from p ÷ (RT) = 101,325 ÷ (287 × 293). Warming the air to 40 &deg;C drops it to 1.127.

### Can I use 287 for natural gas?

No. Methane has 518 J/(kg&middot;K), 80 percent higher. Using air&rsquo;s value would overstate density by a factor of 1.8 at the same pressure and temperature.

### How does R affect the speed of sound?

Through a = &radic;(&gamma;RT). Air at 293 K gives 343 m/s; helium, with R = 2,077 and &gamma; = 1.67, gives 1,007 m/s at the same temperature.

### How accurate is the kJ conversion?

Exact. The factor 1,000 is the SI definition of kilo, so no rounding is introduced beyond the display limit.

## Method and sources

Methodology: Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: 2026-11-19.
- Linear conversion through J/(kg·K): result = value × factor(from) ÷ factor(to).
- Factors applied: 1 kJ/(kg·K) = 1000 J/(kg·K).
- Every factor is an exact decimal SI prefix of the base unit, so no rounded constant is involved.
- Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.