# R-Value Calculator

Calculate the thermal resistance (R-value) of a material from its thickness and thermal conductivity.

## Quick answer

**Quick answer:** with the default inputs (3.5 in, 0.27 BTU·in/(hr·ft²·°F)), the r-value is **12.96**. Change any input to update the result.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Material thickness | 3.5 | in |
| Thermal conductivity (k) | 0.27 | BTU·in/(hr·ft²·°F) |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| R-value | 12.963 |  |

## Formula

```text
R = thickness ÷ k
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Material thickness | number | in | 3.5 |
| Thermal conductivity (k) | number | BTU·in/(hr·ft²·°F) | 0.27 |

## Outputs

| Result | Format |
| --- | --- |
| R-value | primary |
| R-value | number |

## How it works

### What the R-value number means

For 3.5 in of fiberglass with a conductivity of 0.27, the calculator returns **R-12.96**. That is the thermal resistance of the material itself, in ft²&middot;hr&middot;&deg;F per BTU: it tells you how many BTUs per hour pass through one square foot for each degree of temperature difference across it. The higher the number, the slower the heat moves.

#### Why the gauge reads low

The gauge on this page reads Low below 13, Moderate from 13 to 30, and High above 30. A 2x4 cavity lands at the bottom of that range on purpose: R-13 is a cavity fill, not a whole wall. The assembly it sits in, with drywall, sheathing, siding and air films, reaches roughly 15.3. That distinction catches more people than the arithmetic does.

### The formula and its units

Two inputs, one division. **t** is thickness in inches and **k** is thermal conductivity in BTU&middot;in/(hr&middot;ft²&middot;&deg;F). The inch in the k unit cancels the inch in the thickness, which is why R comes out ready to use: double the thickness and you double the R, with no extra conversion step.

The k unit is the awkward part. Conductivity is measured per inch of thickness here, not per meter, because that is how US insulation is sold. A material rated k = 0.25 conducts one quarter of a BTU per hour through a one-inch slab, one square foot in area, at one degree of difference. Lower k means better insulation, so k and R pull in opposite directions.

Metric values use RSI, where thickness is in meters and conductivity in W/(m&middot;K). One RSI unit equals 5.678 R, so R-12.96 is RSI 2.28. Divide an R-value by 5.678 to compare it with a European datasheet, and multiply to go the other way.

### Worked example: a 2x4 wall cavity

A 2x4 stud is 3.5 in deep, so the cavity holds 3.5 in of insulation. With fiberglass at k = 0.27: **R = 3.5 ÷ 0.27 = 12.96**. That is the R-13 on the bag, and the bag is right: the labeled number is rounded and measured at a slightly different density, not recalculated from the nominal stud depth.

Switch to mineral wool at k = 0.23 and the same 3.5 in gives **15.22**. Switch to closed-cell spray foam at k = 0.154 and it gives **22.73**, which is why 3 in of closed-cell foam outperforms a full 3.5-in batt despite leaving half an inch of stud exposed. The thickness did not change; the conductivity did.

Push the same fiberglass into a 3-in furring space and you get 3 ÷ 0.27 = **11.1**, not 13. Compression squeezes the air out of the glass, raises the effective k, and the R you paid for disappears into a tighter space. A batt that fits loosely beats one that is forced.

### Conductivity and R at 3.5 inches

| Material | k (BTU&middot;in/hr&middot;ft²&middot;&deg;F) | R at 3.5 in |
| --- | --- | --- |
| Polyiso rigid board | 0.16 | 21.88 |
| Closed-cell spray foam | 0.154 | 22.73 |
| XPS rigid board | 0.20 | 17.50 |
| Mineral wool | 0.23 | 15.22 |
| EPS rigid board | 0.25 | 14.00 |
| Open-cell spray foam | 0.26 | 13.46 |
| Fiberglass batt | 0.27 | 12.96 |
| Pine or fir lumber | 0.80 | 4.38 |
| Brick | 5.0 | 0.70 |
| Glass, single pane | 7.0 | 0.50 |
| Concrete | 12.0 | 0.29 |

Read the table down the R column, not the k column, and the ranking is what you expect from a building supply aisle. Note where lumber falls: at R-4.38 for 3.5 in, a stud is a thermal bridge that short-circuits about a third of the cavity it frames. A wall of 2x4s at 16 in on center loses roughly 15–20% of its cavity R to the studs alone.

### Thickness needed for a target R

#### Flipping the formula

Flip the formula to plan a build-up: **t = R × k**. For R-49 at k = 0.27 that is 13.2 in, and 14.7 in if you use loose-fill at k = 0.30. R-38 needs 10.3 in at 0.27, and R-60 needs 16.2 in, which is deeper than any standard stud bay and therefore means blown insulation or a second layer of rigid board.

Batt labels do not track this arithmetic exactly, because manufacturers rate at their own density. A 9.5-in batt is sold as R-30, which implies k = 0.317 rather than 0.27; a 12-in batt is sold as R-38, implying 0.316. Use the label for products and the formula for assemblies, foam thicknesses and anything you are cutting yourself.

### How much R-value the code asks for

| Climate zone | Example city | Ceiling | Wood wall |
| --- | --- | --- | --- |
| 1 | Miami, FL | R-30 | R-13 |
| 2 | Houston, TX | R-38 | R-13 |
| 3 | Atlanta, GA | R-49 | R-20 |
| 4 | New York, NY | R-60 | R-20 + 5 |
| 5 | Chicago, IL | R-60 | R-20 + 5 |
| 6 | Minneapolis, MN | R-60 | R-20 + 5 |
| 7 | Duluth, MN | R-60 | R-20 + 10 |
| 8 | Fairbanks, AK | R-60 | R-20 + 10 |

These are the 2021 IECC ceiling minimums for wood-frame homes; several states still enforce the 2015 table, which is one step lower from zone 3 upward. Hitting R-60 in a zone 5 attic takes 16.2 in at k = 0.27, so check the joist depth before you price the job: most attics run out of room around 14 in, and the blown insulation then buries the top plate.

### What moves the number

- Thickness is linear: 7 in of the same fiberglass is exactly R-25.93, twice the default
- Conductivity is inverse: halving k from 0.27 to 0.135 doubles R at the same depth
- Compression costs R without saving space: 3.5 in squeezed to 3 in drops from 12.96 to 11.1
- Moisture raises k in fibrous insulation, and a wet batt can lose 30–50% of its rating until it dries
- Framing is not in the formula at all, and studs at 16 in on center cut whole-wall R by 15–20%
- Age matters for foam: closed-cell blows with a gas that escapes slowly, so the 20-year R is lower than day one

### Where the R-value math misleads

R-values add in series only when the layers are continuous. A wall with R-13 between studs and R-5 of rigid foam on the outside is not R-18 everywhere: it is R-18 at the studs and R-18 in the cavity only if the foam is uninterrupted, which is why foam sheathing is valued out by the fraction of framing it covers.

The other trap is treating R as a comfort guarantee. R-12.96 slows heat flow, it does not stop air. A 3.5-in wall with a 1/8-in gap at the sill plate leaks more heat on a windy 15 &deg;F day than the difference between R-13 and R-15 ever will. Air-seal first, then add R.

- Whole-wall R is always lower than cavity R, by 15–20% with standard framing
- A radiant barrier is not an R-value product and cannot be added as one
- R-value is tested at a fixed mean temperature, so performance shifts at very cold surface temperatures
- Two layers of R-13 with staggered joints beat one layer of R-26 board at the same total thickness

## FAQ

### What R-value do I need for my attic?

Zone 1 asks for R-30, zones 2 to 3 for R-38 to R-49, and zones 4 to 8 for R-60 under the 2021 IECC. At k = 0.27 that R-49 is 13.2 in deep and R-60 is 16.2 in.

### How do I calculate R-value from thickness?

Divide thickness in inches by conductivity. A 3.5-in batt at k = 0.27 is 3.5 ÷ 0.27 = 12.96. Two inches of closed-cell foam at k = 0.154 is 12.99.

### What is the R-value of a 2x6 wall?

A 2x6 cavity is 5.5 in deep, so fiberglass at k = 0.27 gives 5.5 ÷ 0.27 = 20.37, sold as R-21. The full assembly, with drywall and sheathing, lands near R-23.

### Is R-13 enough for an exterior wall?

Only in zones 1 and 2. Zones 3 and up require R-20 or R-20 plus 5 of continuous sheathing, because the studs cut the cavity value by 15–20% before any air leaks are counted.

### Does compressing insulation lower its R-value?

Yes. An R-13 batt forced into 3 in of space becomes 3 ÷ 0.27 = 11.1, a loss of about 15%. Buy the depth you have rather than squeezing a thicker batt into it.

### How many inches of insulation do I need for R-49?

13.2 in of fiberglass at k = 0.27, or 14.7 in of loose-fill at k = 0.30. Blown cellulose at k = 0.28 needs 13.7 in for the same target.

### What is the difference between R-value and RSI?

RSI is the metric version of the same idea, in m²&middot;K/W. One RSI unit is 5.678 R, so R-12.96 equals RSI 2.28 and R-60 equals RSI 10.57.

### Do two layers of insulation add up?

Yes, if they stay full thickness. Two 3.5-in layers of fiberglass at k = 0.27 give 25.93, exactly double one layer. Compress either layer and the total drops below the sum.

### Is a higher R-value always better?

For heat flow, yes, but the returns flatten. Going from R-13 to R-26 halves conduction through the cavity; going from R-40 to R-53 cuts it by a quarter for the same added inches. Air sealing and window U-factor usually pay back sooner at that point.

## Method and sources

Methodology: Cost ranges reflect 2026 U.S. national averages for materials and labor; regional pricing varies, so use results as a planning baseline and confirm with local quotes.

Last updated: 2026-11-17.
- R-value = thickness ÷ thermal conductivity (k).