---
slug: pressure-differential-converter
title: "Pressure Differential Converter"
category: unit
updated: 2026-11-19
canonical: https://calcseed.com/c/unit/pressure-differential-converter/
html: /c/unit/pressure-differential-converter/
---

# Pressure Differential Converter

Convert pressure differences between psi, kPa, bar, inches of mercury and millimetres of mercury.

## Quick answer

**Pressure differential converter** — 1 bar = 100 kPa, and 1 inHg = 3.38639 kPa.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Value | 100 |  |
| From | kpa |  |
| To | psi |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Result | 14.5038 |  |

## Formula

```text
1 psi = 6,894.757 Pa  &middot;  1 bar = 100 kPa = 14.5038 psi  &middot;  1 inHg = 25.4 mmHg = 3.38639 kPa
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Value | number |  | 100 |
| From | select |  | kpa |
| To | select |  | psi |

## Outputs

| Result | Format |
| --- | --- |
| Result | primary |
| Result | unit |

## How it works

### What this converter does

This tool converts a **pressure difference** between pascals, psi, kilopascals, bar, inches of mercury and millimetres of mercury. It is built for the difference across a filter, an orifice plate or a gauge port, not for absolute pressure. At the defaults, 100 kPa comes back as **14.5 psi**.

### The factors and where they come from

The pascal is one newton per square metre, the SI unit everything else is measured against. A psi is a pound-force on a square inch: 4.448222 N ÷ 0.00064516 m² = **6,894.757 Pa**. A bar is defined as exactly 100,000 Pa, which is why bar and kPa convert by a clean factor of 100 and nothing else on this page does.

The mercury units come from manometers. One millimetre of mercury is 133.322387 Pa, the pressure of a 1 mm column of mercury at 0 &deg;C under standard gravity. An inch of mercury is simply 25.4 mm of the same column, so 1 inHg = 3,386.389 Pa. Both are exact by definition once you fix the density of mercury and the value of g.

### Worked example: 100 kPa across a filter

Take 100 kPa, the default. In psi: 100,000 ÷ 6,894.757 = **14.504 psi**. In inches of mercury: 100,000 ÷ 3,386.389 = **29.529 inHg**. In millimetres of mercury: 100,000 ÷ 133.322387 = 750.06 mmHg. And because a bar is 100,000 Pa, 100 kPa is exactly 1 bar, or 0.987 atm.

That cluster is worth holding in your head: 100 kPa, 1 bar, 14.5 psi and 29.5 inHg all describe roughly one atmosphere. A differential sensor reading 100 kPa is therefore seeing a full atmosphere of push, which is enormous for a duct and ordinary for a compressed-air line at 7 bar working pressure.

### Pressure differentials at a glance

| From | To | Multiply by |
| --- | --- | --- |
| kPa | psi | 0.145038 |
| psi | kPa | 6.89476 |
| bar | psi | 14.5038 |
| inHg | kPa | 3.38639 |
| inHg | mmHg | 25.4 |
| mmHg | Pa | 133.322 |
| atm | kPa | 101.325 |

The inHg row is the one technicians use for vacuum work. A refrigeration gauge reading 29.92 inHg is a perfect vacuum at sea level, and 15 inHg is roughly half an atmosphere removed, about 50.8 kPa of differential. Anything below 5 inHg on a suction line is a system that is nearly empty.

### Where differential pressure is measured

#### HVAC, filters and ducts

Air-side work is quoted in inches of water column, and 1 in w.c. is 249.09 Pa. A clean pleated filter drops 0.2–0.3 in w.c., which is **50–75 Pa**, and a loaded one climbs past 0.5 in w.c. or 125 Pa. A supply duct designed for 0.5–1.0 in w.c. of static pressure is running at 125–249 Pa, so a 250 Pa reading on a duct gauge is a system at the top of its design range.

Because 250 Pa is almost exactly 1 in w.c., you can convert air readings in your head: multiply inches of water by 250 to get pascals, then divide by 1,000 for kPa. A 2.5 in w.c. fan curve is 623 Pa or 0.62 kPa, which is how the same specification appears on a European datasheet.

#### Medical and process readings

Blood pressure is the most familiar mercury reading, and the units are still mmHg on every cuff. A 120/80 reading is **16.0 kPa over 10.7 kPa**, since 120 × 133.322 = 15,999 Pa and 80 × 133.322 = 10,666 Pa. A process transmitter ranged 0–250 Pa with a 4–20 mA output moves 15.625 Pa per mA, so a reading of 12 mA is 125 Pa.

### Gauge, absolute and differential are three different numbers

A tire gauge showing 32 psi is reading **gauge pressure**, the amount above atmosphere. Add 14.696 psi and you get 46.696 psia, the absolute pressure a sensor inside the tire would see. This converter works on differences, so 100 kPa in equals 100 kPa out no matter which reference you used, but the moment you mix a psig figure with a psia figure the error is a full atmosphere, 101.325 kPa.

Vacuum readings are the usual trap. A gauge at 29.92 inHg of vacuum is at zero absolute pressure, not at 29.92 inHg of positive pressure. Convert it as a positive 101.3 kPa differential and subtract from atmosphere to get the absolute value, or the sign of your leak rate reverses.

### Precision and rounding

- One percent of 100 kPa is 1 kPa, which is 0.145 psi, so two decimals in psi is already below the accuracy of most gauges.
- Mercury-column factors assume 0 &deg;C; a manometer at 25 &deg;C reads about 0.4% low for the same pressure.
- Convert once from the original reading; chaining kPa to psi to inHg multiplies the rounding error of each step.

- A transmitter ranged 0–250 Pa resolves 15.625 Pa per mA, so a 0.1 mA drift is 1.6 Pa, well below a filter change.
- Duct static is read upstream of the filter and again downstream; the difference is the load, and each tap needs its own zero.
- A gauge that reads zero with both ports open is a differential instrument; one that reads 14.7 psi is absolute.

### Mistakes that produce wrong diagnoses

The first is treating 1 bar as 1 atm. They differ by 1.325 kPa, or 1.31%, which is trivial on a duct and meaningful on a 10 bar calibration where it is 0.13 bar of offset. The second is reading a water-column manometer as mercury. Inches of water and inches of mercury differ by a factor of **13.6**, so a 2 in w.c. reading taken as 2 inHg overstates the pressure by 1,260%.

The third is subtracting two gauge readings taken at different elevations. Air adds about 12 Pa per metre of height at standard density, so a 10 m riser between two duct taps contributes 120 Pa of apparent differential that has nothing to do with the filter. Zero the transmitter across the taps before you trust the number.

## FAQ

### How do I convert kPa to psi?

Multiply by 0.145038. So 100 kPa is 14.50 psi, 250 kPa is 36.26 psi, and 1,000 kPa is 145.04 psi.

### How many mmHg are in an inch of mercury?

Exactly 25.4, because an inch is defined as 25.4 mm. One inHg is 3,386.389 Pa and one mmHg is 133.322 Pa.

### How do I convert bar to kPa?

Multiply by 100. A 2.5 bar compressed-air line is 250 kPa, and 7 bar working pressure is 700 kPa or 101.5 psi.

### Is 100 kPa the same as 1 bar?

Yes, exactly. The bar is defined as 100,000 Pa, so 100 kPa equals 1 bar, which is 14.504 psi and 0.987 atm.

### How many inches of water is 250 Pa?

About 1.00 in w.c., since 1 in w.c. is 249.09 Pa. That is why a 0.5 in w.c. filter spec and a 125 Pa spec describe the same pressure.

### What is 120/80 blood pressure in kPa?

15.999 kPa over 10.666 kPa, from 120 × 0.133322 and 80 × 0.133322. Round to 16.0 and 10.7 kPa.

### What is the difference between psig and psia?

Psig is gauge pressure above atmosphere, psia is absolute. Add 14.696 psi to a gauge reading to get absolute, so 32 psig is 46.696 psia.

### How many psi is a full vacuum?

About 14.7 psi of differential, since a perfect vacuum is 0 psia against 14.696 psia of atmosphere. On a mercury gauge that is 29.92 inHg or 760 mmHg.

### Why is one bar not exactly one atmosphere?

The bar was defined as a round 100,000 Pa in 1904, while standard atmosphere is 101,325 Pa. The gap is 1.325 kPa, or 1.31%.

## Method and sources

Methodology: Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: 2026-11-19.
- SI derived unit: pascal.
- Mercury column: 1 mmHg = 133.322387 Pa.
