slug: ph-calculator
title: "pH Calculator"
category: scientific
updated: 2026-11-17
canonical: https://calcseed.com/c/scientific/ph-calculator/
html: /c/scientific/ph-calculator/
---

# pH Calculator

Convert between hydrogen ion concentration and pH using pH = −log₁₀[H+]. Free and instant.

## Quick answer

**Quick answer:** with the default inputs (0 mol/L), the ph is **7**. At these inputs: pOH = **7**. Change any input to update the result.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| H+ concentration | 1e-7 | mol/L |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| pH | 7 |  |
| pOH | 7 |  |

## Formula

```text
pH = −log₁₀[H⁺]
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| H+ concentration | number | mol/L | 1e-7 |
| pH | number |  | 7 |

## Outputs

| Result | Format |
| --- | --- |
| pH | primary |
| pH | number |
| pOH | number |

## How it works

### What pH actually measures

pH is the negative base-10 logarithm of the hydrogen ion concentration in moles per litre. It compresses a range that spans fourteen orders of magnitude into a number between roughly 0 and 14, and this calculator converts in either direction, returning pH, pOH and the concentration behind them.

The minus sign exists only to make the numbers positive. A hydrogen ion concentration of 10^−7 mol/L is a logarithm of −7, and flipping the sign gives the familiar 7. Without the flip, every neutral solution would be quoted as a negative number.

Invert the relation by raising ten to the negative pH: [H⁺] = 10^−pH. That single step is all you need to go from a meter reading back to a concentration you can put into a rate law or an equilibrium expression.

### Reading the scale without a calculator

Each whole pH unit is a factor of ten in concentration. Moving from pH 5 to pH 4 multiplies [H⁺] by 10, and moving from 5 to 3 multiplies it by 100. This is why a solution at pH 3 is not 40% more acidic than one at pH 5, it is a hundred times more acidic.

Fractional units follow the same rule: 0.3 of a pH unit is a factor of about 2, because 10^0.3 = 2.00. So pH 7.0 and pH 7.3 differ by a factor of two in hydrogen ion concentration, and that is exactly the width of the healthy blood range.

A useful check on any answer: a concentration written in scientific notation with exponent −n has a pH close to n, adjusted by the mantissa. 5.0 × 10^−4 mol/L sits at pH 3.3, one third of a unit below 4.

### Worked example at the defaults

The defaults are a hydrogen ion concentration of 10^−7 mol/L. The logarithm is −7, the negative of that is **pH 7**, and pOH = 14 − 7 = **7** as well. Pure water at 25 &deg;C sits exactly here, with equal hydrogen and hydroxide concentrations of 10^−7 mol/L.

Run it the other way. Enter pH 3.3 and the calculator returns [H⁺] = 10^−3.3 = **5.01 × 10^−4 mol/L**, or 0.501 mmol/L, with pOH 10.7. That concentration is high enough to attack carbon steel at a visible rate, unlike the 0.1 &micro;mol/L of neutral water.

At pH 11.5 the concentration falls to 3.16 × 10^−12 mol/L and pOH drops to 2.5, meaning [OH^−] = 3.16 × 10^−3 mol/L. The pair always multiplies to 10^−14 at 25 &deg;C, which is the only reason the pOH column is free.

### pH values of familiar solutions

| Solution | pH | Hydrogen ion concentration |
| --- | --- | --- |
| Stomach acid | 1.5 | 3.2 × 10^−2 mol/L |
| Lemon juice | 2.0 | 1.0 × 10^−2 mol/L |
| Black coffee | 5.0 | 1.0 × 10^−5 mol/L |
| Milk | 6.7 | 2.0 × 10^−7 mol/L |
| Pure water | 7.0 | 1.0 × 10^−7 mol/L |
| Seawater | 8.1 | 7.9 × 10^−9 mol/L |
| Baking soda solution | 8.3 | 5.0 × 10^−9 mol/L |
| Ammonia cleaner | 11.5 | 3.2 × 10^−12 mol/L |

The span from stomach acid to ammonia cleaner is ten orders of magnitude in concentration, and the pH column expresses that as a range of ten. This is exactly why the log scale exists: a linear axis from 0.032 to 0.0000000000032 mol/L would be unreadable.

### pOH and the number 14

Water self-ionises: H_2_O &rightleftharpoons; H⁺ + OH^−, with K_w_ = [H⁺][OH^−] = 10^−14 at 25 &deg;C. Taking logs of both sides gives pH + pOH = 14, which is where the pOH output comes from and why it costs nothing to compute.

The 14 is a property of water at one temperature, not a law of nature. Ionisation is endothermic, so K_w_ rises as the water warms and pK_w_ falls. At body temperature the sum is 13.62, which puts neutral pH at 6.81 rather than 7.00.

| Temperature | pK_w_ | Neutral pH |
| --- | --- | --- |
| 0 &deg;C | 14.94 | 7.47 |
| 25 &deg;C | 14.00 | 7.00 |
| 37 &deg;C | 13.62 | 6.81 |
| 50 &deg;C | 13.26 | 6.63 |
| 100 &deg;C | 12.27 | 6.14 |

This matters for anyone measuring hot process water. A boiler sample reading pH 6.5 at 100 &deg;C is not acidic at all; it is slightly basic relative to the local neutral point of 6.14. Reporting it against the 25 &deg;C neutral value of 7 would call it corrosive when it is not.

### Where pH measurements drift

- Calibration: a glass electrode drifts by 0.05–0.1 pH units per day, which is a 12–26% concentration error if you use the reading quantitatively.
- Temperature compensation: most meters correct the electrode slope but not the sample chemistry, so a buffer checked at 25 &deg;C is still wrong at 60 &deg;C.
- Low ionic strength: pure water and distilled samples give unstable readings because the electrode needs ions to complete the circuit, often off by 0.3 units or more.
- Sodium error: above pH 12 the glass membrane responds to Na^+ as well as H⁺, and readings come out low by 0.1–0.5 units.
- Stirring and response time: a still sample takes 30–60 s to equilibrate, and reading early biases every value toward the previous solution.

### The mistakes that produce a wrong pH

- Assuming a 0.1 M acid gives pH 1: that holds for HCl, which is fully dissociated, but 0.1 M acetic acid sits at pH 2.88 because only about 1.3% of it ionises.
- Using concentration where activity belongs: at 0.1 M the activity coefficient of H⁺ is about 0.80, so the true pH of 0.1 M HCl is 1.10, not 1.00.
- Forgetting that pH is defined per litre of solution, not per litre of water, so adding 20% ethanol shifts the reading without changing the acid.
- Treating pH as linear when comparing two samples, which turns a factor of 2 into an apparent 0.3.

#### Strong and weak acids diverge fast

A 0.01 M HCl solution gives pH 2.00 exactly. A 0.01 M acetic acid solution gives pH 3.38, because [H⁺] = &radic;(K_a_C) = &radic;(1.75 × 10^−5 × 0.01) = 4.18 × 10^−4. Same nominal concentration, 1.4 pH units apart, a 24-fold difference in hydrogen ion concentration.

#### Dilution does not move pH in proportion

Dilute a strong acid tenfold and pH rises by exactly 1. Dilute a weak acid tenfold and pH rises by only 0.5, because the fraction ionised increases as the solution gets more dilute. Push either one past about 10^−6 M and the water&rsquo;s own 10^−7 contribution takes over, and pH approaches 7 from below without ever crossing it.

## FAQ

### How do you calculate pH from concentration?

Take the negative base-10 log of the hydrogen ion concentration. At the default 10^−7 mol/L the log is −7 and the pH is 7.

### What does a pH of 7 mean?

Neutral at 25 &deg;C, where [H⁺] = [OH^−] = 10^−7 mol/L. At 37 &deg;C the neutral point moves to 6.81.

### Is a lower pH more acidic?

Yes. pH 3 is a hundred times more acidic than pH 5, because each unit is a factor of ten in hydrogen ion concentration.

### What is the pH of 0.1 M HCl?

1.00 by concentration, since HCl is fully dissociated. Correcting for activity at that ionic strength gives about 1.10.

### What is the pH of 0.1 M acetic acid?

2.88. With K_a_ = 1.75 × 10^−5 only about 1.3% ionises, giving [H⁺] = 1.32 × 10^−3 mol/L, far from the 1.00 of a strong acid.

### How much does temperature change pH?

Neutral pH falls from 7.00 at 25 &deg;C to 6.14 at 100 &deg;C. A buffer&rsquo;s pH also drifts, Tris by about 0.028 per &deg;C.

### What is pOH?

The negative log of the hydroxide concentration. At 25 &deg;C, pH + pOH = 14, so pH 7 gives pOH 7 and pH 11.5 gives pOH 2.5.

### How do I go from pH to concentration?

Raise ten to the negative pH. pH 3.3 gives 10^−3.3 = 5.01 × 10^−4 mol/L, and pH 8.1 gives 7.9 × 10^−9 mol/L.

### Why is my pH meter reading 7 in distilled water?

Pure water has almost no ions to carry the electrode current, so readings are unstable and often biased toward 7. Adding a drop of KCl to raise conductivity gives a truer value.

## Method and sources

Methodology: Physical constants follow CODATA 2022 recommended values, and formulas follow standard physics definitions.

Last updated: 2026-11-17.
- pH definition: pH = −log₁₀[H⁺].