# Linear Charge Density Converter

Convert linear charge density between C/m, mC/m and µC/m.

## Quick answer

**Linear Charge Density Converter** — convert between C/m, mC/m, µC/m and more.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Value | 1 |  |
| From | uC/m |  |
| To | C/m |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Result | 0.000001 |  |

## Formula

```text
result = value × factor(from) ÷ factor(to), with 1 C/m = 1, 1 mC/m = 0.001 and 1 &micro;C/m = 0.000001 C/m
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Value | number |  | 1 |
| From | select |  | uC/m |
| To | select |  | C/m |

## Outputs

| Result | Format |
| --- | --- |
| Result | primary |
| Result | unit |

## How it works

### What linear charge density measures

Linear charge density is charge per unit length along a long, thin conductor or beam: the coulomb per metre (C/m) is the SI unit, with mC/m and &micro;C/m used for the small values that real hardware carries. A wire holding 1 &micro;C on every metre has a density of 1 &micro;C/m, written 0.000001 C/m.

The quantity describes objects where one dimension is far longer than the other two: cables, busbars, electron beams, charged filaments. Once you know the density, the electric field around the object follows directly.

### The conversion rule

All three units share the same metre denominator, so conversion reduces to moving a decimal point. Milli is 10&#8315;³ and micro is 10&#8316;, both exact decimal prefixes, which means the factors are definitions rather than measurements.

Because there is no offset and no rounded constant, the only error introduced is the eight-digit display cut-off. Converting &micro;C/m to mC/m shifts three places, and mC/m to C/m shifts another three, so a single value can move nine decades without any loss of precision.

### Worked example: 1 µC/m in C/m

The defaults take 1 &micro;C/m and convert to C/m. Multiply by 0.000001 and divide by 1: **0.000001 C/m**, which the eight-digit display shows as 0.0000 because the value sits six decades below 1.

That rounding is worth understanding before you trust a screen. 1 &micro;C/m is 0.001 mC/m, and only the C/m box loses the digits. Switch the target unit to mC/m to see 0.001, or to &micro;C/m to see 1.

### Conversion table

| µC/m | mC/m | C/m |
| --- | --- | --- |
| 1 | 0.001 | 0.000001 |
| 10 | 0.01 | 0.00001 |
| 100 | 0.1 | 0.0001 |
| 1,000 | 1 | 0.001 |
| 1,000,000 | 1,000 | 1 |

The last row is the useful anchor: a million microcoulombs per metre is exactly one coulomb per metre. Field strengths from a charged line scale with density, so a factor-of-ten error in this table becomes a factor-of-ten error in the predicted voltage gradient.

### Where the number is used

The classical result for an infinite line is E = &lambda; ÷ (2&pi;&epsilon;&#8320;r), where &lambda; is the density in C/m, &epsilon;&#8320; is 8.854 × 10&#8315;&sup1;² F/m and r is the distance from the axis. With &lambda; = 1 &micro;C/m at r = 0.1 m, the field is about 180 kV/m, comfortably above the 30 kV/m breakdown strength of air at standard conditions. That single comparison explains why corona appears on high-voltage hardware.

- High-voltage line design, where conductor surface charge governs corona onset and audible noise.
- Electrostatic precipitators, where the discharge wire carries a controlled density.
- Electron and ion beam columns, where charge per unit length sets the beam&rsquo;s own defocusing force.
- Van de Graaff and belt generators, where the charge deposited per metre of belt sets the terminal current.

#### Typical magnitudes

Bench electrostatic experiments run from 0.01 to 10 &micro;C/m. A transmission conductor under 400 kV service stress carries a few &micro;C/m, which is 1 to 10 × 10&#8315;&#8310; C/m. Particle beam pipes sit far lower, in the nC/m range, which is below any unit in this list.

### Density versus total charge

Linear density is not the charge on the object. A 2 m rod with 3 &micro;C/m carries 6 &micro;C in total, while a 0.5 m segment of the same rod carries 1.5 &micro;C. The density stays constant along the length; the total scales with how much of the length you take. Mixing the two is the most common way a field calculation lands an order of magnitude out.

### Precision and common mistakes

The factors are exact, so any disagreement between two tools is a unit-selection error rather than a numerical one.

- Reading &micro;C/m as mC/m, which overstates the density by a factor of 1,000.
- Using surface charge density (&sigma;, in C/m²) in a formula that expects linear density.
- Forgetting that the field formula assumes an infinite line; at distances comparable to the length the result overstates the field.
- Entering a negative charge magnitude and expecting the field direction to flip inside the converter.

#### Reading small results on screen

When the answer shows 0.0000, the conversion has not failed. The display rounds to four decimals, so anything below 0.00005 reads as zero. Convert to a smaller unit, &micro;C/m rather than C/m, and the significant digits come back.

### Checking a conversion by hand

Each step of three decimal places is one prefix. 1 &micro;C/m moves to 0.001 mC/m, then to 0.000001 C/m. Going the other way, 0.0025 C/m is 2.5 mC/m and 2,500 &micro;C/m. If your hand calculation disagrees by a factor of 1,000, you have almost certainly counted one prefix step too many or too few.

Electrostatic solvers compound the problem by asking for density per unit length in 2D models and in coulombs for 3D ones. A 2D model of a 1 m section with 2 &micro;C/m carries 2 &micro;C, so exporting that geometry into a 3D tool requires multiplying by the modelled length. Check the model depth before comparing outputs from two packages.

## FAQ

### How many C/m is 1 µC/m?

0.000001 C/m. Micro is 10&#8316;, so 1 &micro;C/m is one millionth of a coulomb spread over one metre. In milliunits the same density is 0.001 mC/m.

### How many µC/m is 0.5 mC/m?

500 &micro;C/m. One millicoulomb per metre is 1,000 microcoulombs per metre, so 0.5 mC/m is 500 &micro;C/m, or 0.0005 C/m.

### What is the SI unit of linear charge density?

The coulomb per metre, C/m. The other two units in this converter are decimal prefixes of it: 1 mC/m = 0.001 C/m and 1 &micro;C/m = 0.000001 C/m.

### Why does the result show 0.0000?

The display keeps four decimals. A value like 0.000001 C/m rounds to 0.0000, so choose mC/m or &micro;C/m as the target unit to see the digits.

### How do I get the electric field from linear charge density?

For a long line, E = &lambda; ÷ (2&pi;&epsilon;&#8320;r). With &lambda; = 1 &micro;C/m at 0.1 m the field is about 180 kV/m; doubling the distance halves it.

### Is linear charge density the same as surface charge density?

No. Linear density is C/m along a thin object, surface density is C/m² over an area. A conductor holding 1 &micro;C/m with a 2 mm diameter has a surface density near 0.16 mC/m², because the same charge is squeezed onto 6.28 mm of circumference per metre.

### What charge density does a high-voltage line carry?

A 400 kV conductor typically sits in the few &micro;C/m range, around 1–10 × 10&#8315;&#8310; C/m. That is enough to push the surface gradient past the 30 kV/m corona onset in humid weather.

### Can I enter a negative charge?

The input accepts positive magnitudes only. Enter the absolute value and apply the sign to the field direction afterwards, since the conversion itself is linear and sign-independent.

### How accurate is the conversion?

Exact to the limits of double precision. Both factors are powers of ten, so no rounded physical constant is involved and the only loss is the eight-digit display rounding.

## Method and sources

Methodology: Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: 2026-11-19.
- Linear conversion through C/m: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 mC/m = 0.001 C/m; 1 µC/m = 0.000001 C/m.
- Every factor is an exact decimal SI prefix of the base unit, so no rounded constant is involved.
- Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.