---
slug: irradiance-converter
title: "Irradiance Converter"
category: unit
updated: 2026-11-19
canonical: https://calcseed.com/c/unit/irradiance-converter/
html: /c/unit/irradiance-converter/
---

# Irradiance Converter

Convert irradiance (solar flux) between W/m², mW/cm², kW/m² and W/cm².

## Quick answer

**Irradiance Converter** — convert between W/m², mW/cm², kW/m² and more.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Value | 1000 |  |
| From | W/m2 |  |
| To | mW/cm2 |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Result | 100 |  |

## Formula

```text
result = value × factor(from) ÷ factor(to), with factors in W/m²: W/m² = 1, mW/cm² = 10, kW/m² = 1000, W/cm² = 10000
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Value | number |  | 1000 |
| From | select |  | W/m2 |
| To | select |  | mW/cm2 |

## Outputs

| Result | Format |
| --- | --- |
| Result | primary |
| Result | unit |

## How it works

### What irradiance is

Irradiance is power arriving per unit area, measured in watts per square metre. It is the number that describes sunlight, a laser spot, a UV lamp or the light inside a growth chamber, and it is the input to every solar panel yield calculation. At the defaults, **1,000 W/m²** — one standard sun — converts to **100 mW/cm²**.

Four units cover the field: W/m² and kW/m² for solar and architectural work, mW/cm² for sensors and curing, and W/cm² for lasers. The conversion is one factor ratio: *result = value × factor(from) ÷ factor(to)*.

### Why mW/cm&sup2; is exactly 10 W/m&sup2;

A square centimetre is 1e-4 m², so the same power concentrated on a cm² is 10,000 times the density per m². A milliwatt is 1e-3 W. Dividing 1e-3 by 1e-4 gives **10**, so 1 mW/cm² = 10 W/m² and 1 W/cm² = 10,000 W/m². Both factors are exact, which is why a 1,000 W/m² standard test condition converts to a clean 100 mW/cm².

#### Irradiance versus irradiation

Irradiance is a rate, W/m²; irradiation is energy per area, kWh/m² or MJ/m². Multiply irradiance by time to get irradiation: 1,000 W/m² for 5 hours is 5 kWh/m², which solar designers call five peak sun hours. A day with 5 kWh/m² of irradiation is a good summer day in most of the US, and a winter day in the north can fall to 1–2 kWh/m².

### Worked example at the default settings

Convert 1,000 W/m² to mW/cm²: 1,000 × 1 ÷ 10 = **100 mW/cm²**. The same value is 1 kW/m² and 0.1 W/cm². All four describe standard test conditions for photovoltaics: 1,000 W/m², 25 &deg;C cell temperature and an AM1.5 spectrum.

Now size a panel output. A 400 W module with an area of 1.95 m² receives 1,000 × 1.95 = 1,950 W at standard conditions, so its efficiency is 400 ÷ 1,950 = **20.5%**. At a realistic 800 W/m² it produces about 320 W, and at 200 W/m² under heavy cloud, 80 W — the ratio holds because module current scales almost linearly with irradiance.

### Common irradiance levels

| Situation | W/m² | mW/cm² | kW/m² |
| --- | --- | --- | --- |
| Direct sunlight (clear noon) | 1,000 | 100 | 1.0 |
| Solar constant at top of atmosphere | 1,361 | 136.1 | 1.361 |
| Overcast day | 100–200 | 10–20 | 0.1–0.2 |
| UV index 1 (erythemal) | 0.025 | 0.0025 | 0.000025 |
| Laser curing spot | 10,000 | 1,000 | 10 |
| Industrial UV curing | 50,000 | 5,000 | 50 |

The UV row explains the UV index: one index unit corresponds to 25 mW/m² of erythemal-weighted irradiance, so a UV index of 8 is 200 mW/m², or 0.02 mW/cm². That is four orders of magnitude below sunlight in total power, which is why UV damage is about spectrum rather than raw irradiance.

### Where each unit is used

- Photovoltaics: W/m² for yield modelling, with 1,000 W/m² at STC and performance ratio computed against kWh/m² of irradiation.
- Sensors and optoelectronics: mW/cm² for photodiode responsivity, where 1 mW/cm² at 850 nm on a 1 mm² silicon detector produces roughly 5 &micro;A.
- Laser and LED curing: W/cm² for dose, and 1 W/cm² for 10 s is 10 J/cm², a typical adhesive cure.
- Agriculture and horticulture: PPFD in &micro;mol/m²/s rather than W/m², since plants respond to photon count, not energy; 1,000 W/m² of sunlight is about 2,000 &micro;mol/m²/s.

#### Reading a module curve at other irradiances

Module current scales almost exactly with irradiance, so at 500 W/m² a panel rated 10 A at standard conditions delivers about 5 A. Voltage falls only slightly, from around 34 V to 32 V on a typical 60-cell module, so power drops a little faster than the irradiance ratio alone suggests: a 400 W panel at 800 W/m² delivers about 315 W, just under the 320 W that a strictly linear model would predict.

### Why solar work still quotes 1,000 W/m&sup2;

The 1,000 W/m² standard is not the maximum. The solar constant at the top of the atmosphere is 1,361 W/m², and a clear noon at high altitude can exceed 1,100 W/m² at the surface. The lower figure is a convention that lets manufacturers compare panels, and it happens to sit near the typical peak at sea level with the sun overhead. Measured output above 1,000 W/m² is normal on cold, clear days, and it is one reason inverters are rated with a DC input margin.

Concentration photovoltaics and solar thermal deliberately exceed the standard: a 500-sun system runs at 500,000 W/m², or 50 W/cm². Converting that to W/cm² is a factor of 10,000, so the same concentration quoted as 50 W/cm² and 5 MW/m² describes one receiver, and unit errors at that scale destroy hardware in seconds.

### Precision and measurement

All four factors are exact powers of ten, so the arithmetic carries no error. Measurement does: a calibrated pyranometer is good to &plusmn;2–5%, and a cheap lux meter converted to W/m² can be out by 30% because lux is weighted for human vision, not for power. Calibration certificates state the uncertainty in W/m², and no conversion can improve on it.

### Mistakes worth avoiding

- Reading 1,000 W/m² as 1,000 mW/cm². The correct figure is 100 mW/cm², a tenfold difference.
- Multiplying by 10,000 when going from mW/cm² to W/m². The factor is 100, since 100 mW/cm² is 1,000 W/m².
- Confusing irradiance with irradiation: 1,000 W/m² is a rate, and it becomes 5 kWh/m² only after five hours.
- Comparing a lux reading with a W/m² specification, which mixes a photometric unit with a radiometric one.

## FAQ

### How many mW/cm&sup2; is 1,000 W/m&sup2;?

100 mW/cm², which is standard test conditions for solar panels. The factor is 10 W/m² per mW/cm².

### How do I convert mW/cm&sup2; to W/m&sup2;?

Multiply by 10. A 50 mW/cm² lamp is 500 W/m², and 100 mW/cm² is 1,000 W/m².

### What is 1 sun in W/m&sup2;?

1,000 W/m², or 100 mW/cm², or 1 kW/m². It is a testing convention, not the maximum, since the solar constant is 1,361 W/m².

### How many W/m&sup2; is 1 W/cm&sup2;?

10,000 W/m². A 1 W/cm² laser spot is 10 kW/m², roughly seven times the solar constant of 1,361 W/m².

### Is irradiance the same as solar irradiation?

No. Irradiance is instantaneous power per area in W/m²; irradiation is energy per area in kWh/m². Five hours at 1,000 W/m² gives 5 kWh/m².

### How do I calculate a solar panel output from irradiance?

Multiply irradiance by area and by efficiency. A 400 W panel of 1.95 m² at 1,000 W/m² receives 1,950 W and converts at 20.5%.

### What irradiance does a UV index of 5 represent?

About 125 mW/m² of erythemal-weighted UV, since one index unit is 25 mW/m². That is 0.0125 mW/cm².

### How bright is a cloudy day in W/m&sup2;?

Roughly 100–200 W/m², which is 10–20 mW/cm². Panels still produce 10–20% of their rated output under that light.

### Why is 1,000 W/m&sup2; used for panel ratings?

It is a round, reproducible reference close to sea-level peak sun, agreed so that a 400 W panel means the same thing in every market. Real sites vary from 100 to 1,100 W/m².

## Method and sources

Methodology: Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: 2026-11-19.
- Linear conversion through W/m²: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 mW/cm² = 10 W/m²; 1 kW/m² = 1000 W/m²; 1 W/cm² = 10000 W/m².
- Every factor is an exact decimal SI prefix of the base unit, so no rounded constant is involved.
- Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.
