slug: illuminance-converter
title: "Illuminance Converter"
category: unit
updated: 2026-11-19
canonical: https://calcseed.com/c/unit/illuminance-converter/
html: /c/unit/illuminance-converter/
---

# Illuminance Converter

Convert illuminance between lux, foot-candles and phots.

## Quick answer

**Illuminance Converter** — convert between Lux (lx), Foot-candle (fc), Phot (ph) and more.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Value | 500 |  |
| From | lx |  |
| To | fc |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Result | 46.4515 |  |

## Formula

```text
result = value × factor_from_ ÷ factor_to_  
1 lx = 1 lm/m² &#183; 1 fc = 1 lm/ft² = 10.76391041671 lx &#183; 1 phot = 1 lm/cm² = 10,000 lx
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Value | number |  | 500 |
| From | select |  | lx |
| To | select |  | fc |

## Outputs

| Result | Format |
| --- | --- |
| Result | primary |
| Result | unit |

## How it works

### What this converter returns

Illuminance is the light falling on a surface, measured in lumens per unit area. This tool converts it across three units: lux, foot-candles and phots. The default is **500 lx** into fc, which returns **46.45 fc**, and that pair matters because lighting standards are written in lux almost everywhere except the United States, which still writes foot-candles.

### Where the three factors come from

The lux is one lumen per square metre and carries a factor of 1. The phot is one lumen per square centimetre, and a square centimetre is 10^−4 m², so 1 phot is exactly 10,000 lx. The phot is the oldest of the three and survives mainly in older German and Japanese optics literature; it is a factor of ten thousand, not a rounded constant.

The foot-candle is one lumen per square foot, so its factor is the reciprocal of the square foot in square metres. The international foot is 0.3048 m, and 0.3048² = 0.09290304 m², so 1 fc = 1 ÷ 0.09290304 = 10.76391041671 lx. The reciprocal is 0.09290304 lx per fc, which is why converting the other way multiplies by a number slightly under 0.1.

### Worked example at the default settings

Take 500 lx into fc. The arithmetic is 500 × 1 ÷ 10.76391041671 = **46.452 fc**, shown as 46.45. Into phots it is 500 ÷ 10,000 = 0.05 ph, which is a useful reminder that the phot is a large unit: a brightly lit office is a small fraction of one phot.

The reverse check is worth doing once. 46.452 fc × 10.7639 = 500.0 lx, so the pair round-trips exactly. If you are reading a US lighting plan that says 50 fc, convert it to 538 lx before comparing it with a European standard that asks for 500 lx, and the two are within 8% of each other rather than identical.

### Illuminance in everyday settings

| Setting | lux | foot-candles |
| --- | --- | --- |
| Full moon, clear night | 0.25 | 0.023 |
| Residential street lighting | 15 | 1.39 |
| Corridor and stairs | 100 | 9.29 |
| Living room, general | 150 | 13.9 |
| Office task lighting | 500 | 46.5 |
| Overcast daylight | 1,000 | 92.9 |
| Direct sunlight | 100,000 | 9,291 |

The table also explains why daylight dominates any artificial scheme. An office at 500 lx is 0.5% of direct sunlight, so a window seat can be 200 times brighter than the desk beside it. That ratio, not the absolute level, is what makes glare and screen washout complaints so hard to fix with lamps alone.

### Where lux and foot-candles disagree

- Lighting design: the Illuminating Engineering Society publishes recommendations in foot-candles while EN 12464-1 uses lux, so a 50 fc office target is 538 lx.
- Photography and film: exposure meters used to read in foot-candles, and 1 fc of scene light corresponds to about 10.76 lx on the sensor plane.
- Horticulture: grow-light charts mix lux, foot-candles and PPFD, and 10,000 lx of white light is 929 fc but only about 150 &micro;mol/m²/s of usable photons.
- Road and car-park lighting: standards are in lux, and a 15 lx residential street is 1.39 fc, dim enough that a 50 fc parking lot is a different class of design.
- Museum and gallery work: 50 lx for sensitive works is 4.65 fc, and the 50 lx limit exists to protect pigments rather than to save energy.

The horticulture row is the one that misleads most often. Lux is weighted to the human eye, which peaks near 555 nm, while plants absorb mostly red and blue. A lamp can read 10,000 lx and still deliver less usable light than another lamp reading 6,000 lx, which is why growers convert to PPFD and stop trusting lux once the fixture is not white.

#### Designing to a target illuminance

A target in lux is reached by dividing the lumens delivered to the surface by its area. A 4 m × 5 m room is 20 m², so 500 lx needs 10,000 lm reaching the floor. With a utilisation factor of 0.6 and a maintenance factor of 0.8, the installed lumens must be 10,000 ÷ 0.48 = 20,833 lm, which is roughly fourteen 1,500 lm panels rather than the ten the bare arithmetic suggests.

### Mistakes that shift the result

- Multiplying by 10 instead of 10.76: 500 lx is 46.5 fc, not 50 fc, and the 7% gap is visible in a compliance check.
- Confusing illuminance with luminance: lux measures light falling on a surface, while cd/m² measures light leaving it.
- Confusing lux with lumens: lumens are the total output of a lamp, lux is that output spread over an area.
- Assuming a lamp datasheet gives lux: most give lumens or candela, and you need the distance or the room geometry to reach lux.

The lumens-versus-lux error is the most common one in retail lighting. A 3,000 lm downlight at 3 m gives roughly 3,000 ÷ (4&pi; × 9) = 26.5 lx directly below if it were isotropic, but a real reflector concentrates that into perhaps 300 lx over a small pool. The lamp output did not change; the distribution did, and no single lux figure describes both.

### Precision and rounding

The phot factor is exact and the foot-candle factor is exact to twelve digits, so the arithmetic introduces no error. What limits the answer is the measurement: a lux meter is typically good to 4% and its cosine correction is worse at low angles. Quoting 46.452 fc from a 500 lx nominal target overstates the certainty; 46 fc is the honest figure.

Lux meters are cosine-corrected, meaning the reading falls as light arrives at a shallow angle. A surface lit at 60 degrees from normal receives only half the vertical illuminance, so 500 lx measured perpendicular becomes 250 lx on a tilted desk. That geometry, not the lamp, explains most gaps between a designed level and a measured one.

#### An inverse-square check

Move a lamp twice as far and illuminance falls to a quarter, not a half. A 1,000 lm isotropic source is 79.6 cd, so at 2 m it delivers 79.6 ÷ 4 = 19.9 lx, and at 4 m it delivers 79.6 ÷ 16 = 5.0 lx. That 4:1 drop over a doubling of distance explains why ceiling height changes a lighting design far more than swapping lamps of similar output.

## FAQ

### How do I convert lux to foot-candles?

Divide by 10.7639. For example, 500 lx ÷ 10.7639 = 46.45 fc, and 100 lx is 9.29 fc.

### How many lux is 1 foot-candle?

10.7639 lx, because a foot-candle is one lumen per square foot and 1 ft² is 0.092903 m².

### How many lux is 1 phot?

Exactly 10,000 lx, since a phot is one lumen per square centimetre and 1 cm² is 10&#8315;&#8308; m².

### What is a good office lighting level?

About 500 lx for general office work, which is 46.5 fc. Detailed drawing work may need 750 lx (69.7 fc) and corridors 100 lx (9.29 fc).

### How bright is direct sunlight in lux?

Roughly 100,000 lx, which is 9,291 fc. Overcast daylight is about 1,000 lx, or 92.9 fc, a hundredfold difference.

### Is lux the same as lumens?

No. Lumens measure a lamp&rsquo;s total output; lux measure lumens per square metre arriving at a surface. A 3,000 lm lamp gives very different lux at 1 m and at 3 m.

### How bright is moonlight in lux?

A full moon gives about 0.25 lx, or 0.023 fc. That is roughly 1/400,000 of direct sunlight, which is why night vision needs a different exposure entirely.

### How do I convert foot-candles to lux quickly?

Multiply by 10.76. A 50 fc target is 538 lx, and a 20 fc corridor is 215 lx.

### Why do two lamps with the same lux look different?

Lux is weighted to the human eye at 555 nm, so a green-heavy lamp reads high while a red-heavy lamp reads low. Colour rendering and spectrum change appearance without changing the lux figure.

## Method and sources

Methodology: Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: 2026-11-19.
- Linear conversion through lx: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 Foot-candle (fc) = 10.76391041671 lx; 1 Phot (ph) = 10000 lx.
- The phot is exactly 10000 lx. The foot-candle is one lumen per square foot, so its factor is 1/0.09290304 from the international foot, stored rounded.
- Every factor is an exact definition or an exact decimal SI prefix. The stored decimals are rounded only in their last digits — at most 2.6e−12% relative — which is negligible for any measurement.