# Heat Transfer Coefficient Converter

Convert heat transfer coefficient between W/(m²·K) and BTU/(h·ft²·°F).

## Quick answer

**Heat Transfer Coefficient Converter** — convert between W/(m²·K), BTU/(h·ft²·°F), kcal/(h·m²·°C) and more.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Value | 10 |  |
| From | W/m2K |  |
| To | BTU/hft2F |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Result | 1.7611 |  |

## Formula

```text
q = h × A × &Delta;T, and result = value × factor(from) ÷ factor(to) with factors 1 W/(m²&middot;K), 5.678263 BTU/(h&middot;ft²&middot;&deg;F), 1.163 kcal/(h&middot;m²&middot;&deg;C)
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Value | number |  | 10 |
| From | select |  | W/m2K |
| To | select |  | BTU/hft2F |

## Outputs

| Result | Format |
| --- | --- |
| Result | primary |
| Result | unit |

## How it works

### What this converter returns

The heat transfer coefficient, usually written h, tells you how many watts cross one square metre of surface for each kelvin of temperature difference. This page converts between W/(m²&middot;K), BTU/(h&middot;ft²&middot;&deg;F) and kcal/(h&middot;m²&middot;&deg;C). At the defaults it turns **10 W/(m²&middot;K)** into **1.76 BTU/(h&middot;ft²&middot;&deg;F)**, a typical natural-convection value in air.

The number matters because it sets the size of every heat exchanger, radiator and cold plate. Double h and you halve the area needed for the same duty. It also decides whether a design is limited by the surface or by the material behind it, since the film coefficient and the wall conductance compete in series.

### The conversion rule

The definition is q = h × A × &Delta;T: watts equal the coefficient times area times temperature difference. That fixes the SI unit as W divided by m² and K. Every other unit in the list is the same fraction with imperial or metric-engineering pieces substituted.

The BTU factor is 1,055.05585262 J spread over 3,600 s, 0.09290304 m² and 5/9 K. Multiplying the denominator gives 185.80, and 1,055.05585262 ÷ 185.80 = **5.678263**. The kilocalorie factor is simpler because only the time changes: 4,184 J ÷ 3,600 s = **1.163 W/(m²&middot;K)**.

#### Why the BTU figure is not 5.67 or 5.68

The exact value depends on which BTU you use. This tool uses the international table BTU, 1,055.05585262 J, giving 5.678263. Older steam tables use the thermochemical BTU at 1,054.35 J, which yields 5.6745, a difference of 0.07 percent. Both round to 5.68, and neither is wrong enough to matter in a heat exchanger calculation where film coefficients are only known to 20 percent.

### Worked example at the defaults

Convert 10 W/(m²&middot;K) to BTU units. Divide by 5.678263 and you get **1.761 BTU/(h&middot;ft²&middot;&deg;F)**. In kilocalorie units the same value is 10 ÷ 1.163 = 8.598 kcal/(h&middot;m²&middot;&deg;C).

Now size a surface with it. A 2 m² panel at h = 10 and a 25 K difference carries 10 × 2 × 25 = 500 W. Raise h to 50 W/(m²&middot;K) with a fan and the same panel carries 2,500 W, which is why forced air is standard on anything above a few hundred watts.

| Unit | In W/(m²&middot;K) | One W/(m²&middot;K) equals |
| --- | --- | --- |
| W/(m²&middot;K) | 1 | 1 W/(m²&middot;K) |
| BTU/(h&middot;ft²&middot;&deg;F) | 5.678263 | 0.1761 BTU/(h&middot;ft²&middot;&deg;F) |
| kcal/(h&middot;m²&middot;&deg;C) | 1.163 | 0.8598 kcal/(h&middot;m²&middot;&deg;C) |

### Coefficients for common situations

These ranges come from standard heat transfer references and hold for clean surfaces without fouling. Fouling can cut a water coefficient in half, which is why industrial exchangers carry a fouling allowance on top of the clean h.

| Situation | W/(m²&middot;K) | BTU/(h&middot;ft²&middot;&deg;F) |
| --- | --- | --- |
| Air, natural convection | 5–25 | 0.9–4.4 |
| Air, forced convection | 25–250 | 4.4–44 |
| Water, natural convection | 100–1,000 | 18–176 |
| Water, forced convection | 500–10,000 | 88–1,761 |
| Boiling water | 3,000–100,000 | 528–17,610 |
| Condensing steam | 5,000–100,000 | 880–17,610 |

The spread inside a single row is the practical lesson. Air convection spans 5 to 250, a factor of fifty, so a design that assumes 100 W/(m²&middot;K) without specifying airflow can miss by 20 times. State the airflow, the surface orientation and whether the surface is finned before you defend an h value.

#### h is not U

h is a single film: the resistance between a surface and the fluid touching it. U is the overall coefficient of an assembly and includes every layer plus both films. A double-glazed window has h around 8 W/(m²&middot;K) on the inside surface but U of about 1.4 W/(m²&middot;K), because the glass and the cavity add resistance in series. Converting a U-value with this tool gives the right number in the wrong quantity.

### Where the unit mix causes trouble

- Converting a U-value as if it were h and then adding it to film coefficients in series as if all three were films.
- Dropping the &deg;F from BTU/(h&middot;ft²&middot;&deg;F). The bare BTU/(h&middot;ft²) is a heat flux, not a coefficient, and differs by the temperature term.
- Using 5.68 as a reciprocal. One BTU unit is 5.678 W units, so a value of 5.68 BTU converts to 32.3 W, not 1 W.
- Mixing kcal/(h&middot;m²&middot;&deg;C) with kcal/(h&middot;m&middot;&deg;C), which is a per-length conductance for pipes and cylinders.

The reciprocal mistake is the one that changes answers by a factor of 32. The factor direction is fixed by the definition: an imperial unit is worth more watts than an SI unit, so multiplying by 5.678 takes BTU values into SI, and dividing takes SI into BTU.

### Common mistakes and checks

- Quoting h for a finned surface as if it were the bare-surface value. Fins add area, not coefficient, so the effective conductance rises while h stays put.
- Ignoring the difference between a clean and a fouled exchanger. A 20 percent fouling allowance is normal in water service.
- Assuming a condensing coefficient stays high after non-condensable gas enters. One percent air in steam can cut h by half.
- Applying a flat-plate correlation to a cylinder without checking the diameter-to-boundary-layer ratio.

### Precision and rounding

The factors are exact to the definitions of the BTU, foot and degree, truncated here at seven figures. That precision is irrelevant next to the physical uncertainty: 20 percent is a good day for a natural-convection estimate. Report two significant figures, as in 1.8 BTU/(h&middot;ft²&middot;&deg;F) or 8.6 kcal/(h&middot;m²&middot;&deg;C), and keep three only when the number feeds a fouling calculation.

## FAQ

### How do I convert W/(m&sup2;&middot;K) to BTU/(h&middot;ft&sup2;&middot;&deg;F)?

Divide by 5.678263. A coefficient of 10 W/(m²&middot;K) is 1.76 BTU/(h&middot;ft²&middot;&deg;F).

### How many W/(m&sup2;&middot;K) are in 1 BTU/(h&middot;ft&sup2;&middot;&deg;F)?

5.678263. A US radiator rated at 2 BTU units is 11.36 W/(m²&middot;K).

### How do I convert kcal/(h&middot;m&sup2;&middot;&deg;C)?

Multiply by 1.163. A value of 100 kcal units is 116.3 W/(m²&middot;K), and 860 kcal units is 1,000 W/(m²&middot;K).

### What is a typical heat transfer coefficient for air?

5 to 25 W/(m²&middot;K) in natural convection and 25 to 250 with a fan. That is 0.9 to 44 BTU/(h&middot;ft²&middot;&deg;F) across the whole range.

### What is a typical value for water?

100 to 1,000 W/(m²&middot;K) natural and 500 to 10,000 forced. Boiling pushes it to 3,000–100,000, or 528–17,610 in BTU units.

### Why is the BTU factor 5.678 rather than 5.67?

Because it combines four conversions: 1,055 J per BTU, 3,600 s per hour, 0.0929 m² per ft² and 5/9 K per &deg;F. The exact product gives 5.678263.

### Is h the same as a U-value?

No. h is one surface film, U is the whole assembly. A window can have h near 8 W/(m²&middot;K) and U near 1.4 W/(m²&middot;K) at the same time.

### How do I find the area a surface needs?

Divide the duty by h and by &Delta;T. A 500 W duty at h = 10 and 25 K needs 2 m², and doubling h halves that to 1 m².

### Does fouling change the coefficient?

Yes, often by 20 to 50 percent in water service. Add a fouling resistance rather than reducing h, so the clean value stays traceable.

### How precise should I report the result?

Two significant figures. Physical uncertainty of 20 percent dwarfs the seven-figure precision of the factor, so 1.8 BTU/(h&middot;ft²&middot;&deg;F) is honest.

## Method and sources

Methodology: Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: 2026-11-19.
- Linear conversion through W/(m²·K): result = value × factor(from) ÷ factor(to).
- Factors applied: 1 BTU/(h·ft²·°F) = 5.678263 W/(m²·K); 1 kcal/(h·m²·°C) = 1.163 W/(m²·K).
- The kilocalorie factor is exact (4.1868 J per International Table calorie, 3600 s per hour). The BTU per hour-square foot-°F also divides by 5/9, since one Fahrenheit degree is 5/9 kelvin, and is stored rounded.
- The SI prefixes are exact; the BTU/(h·ft²·°F) factor is stored as a rounded decimal, the largest deviation being 6.0e−6% relative. A result carries that rounding on top of floating-point arithmetic.