# Heat Flux Converter

Convert heat flux between W/m², BTU/(h·ft²) and W/cm².

## Quick answer

**Heat Flux Converter** — convert between W/m², BTU/(h·ft²), W/cm² and more.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Value | 100 |  |
| From | W/m2 |  |
| To | BTU/hft2 |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Result | 31.6998 |  |

## Formula

```text
result = value × factor_from_ ÷ factor_to_  &middot;  q = Q ÷ A  &middot;  1 BTU/(h&middot;ft²) = 3.15459 W/m²  &middot;  1 W/cm² = 10,000 W/m²  &middot;  1 kcal/(h&middot;m²) = 1.163 W/m²
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Value | number |  | 100 |
| From | select |  | W/m2 |
| To | select |  | BTU/hft2 |

## Outputs

| Result | Format |
| --- | --- |
| Result | primary |
| Result | unit |

## How it works

### What heat flux measures

Heat flux is the rate at which heat crosses a unit area, in watts per square metre. It is not the total heat and not the temperature: it is power density, and it is what determines whether a surface stays cool or melts. This converter handles W/m², BTU per hour per square foot, W/cm² and kcal per hour per square metre. At the defaults it turns 100 W/m² into 31.7 BTU/(h&middot;ft²).

### The conversion formula

The watt per square metre is the coherent unit. The watt per square centimetre is an exact ten thousand, because a square centimetre is 10^-4 m². The kilocalorie per hour per square metre is 1.163 W/m², since one International Table calorie is 4.1868 J and an hour is 3,600 seconds: 4,186.8 ÷ 3,600 = 1.163 exactly.

The BTU per hour per square foot is the awkward one: 1,055.05585262 J ÷ 3,600 s ÷ 0.09290304 m² = **3.15459 W/m²**. That factor is rounded because the BTU is a defined non-SI unit, but the rounding sits at the seventh digit, far below any measurement uncertainty.

### Worked example: 100 W/m&sup2;

At the defaults the value is 100 and the units run from W/m² to BTU/(h&middot;ft²): 100 ÷ 3.15459 = **31.7 BTU/(h&middot;ft²)**. That is a modest flux, roughly what a person gives off per square metre of skin at rest, and it is the sort of number that appears in building-envelope calculations.

The same 100 W/m² is 0.01 W/cm² and 86.0 kcal/(h&middot;m²). The three answers look unrelated until you notice that each unit was chosen for a different industry: W/m² for physics, W/cm² for electronics cooling, kcal/(h&middot;m²) for European heating practice.

### Heat flux conversions at a glance

| From | To unit | Multiply by |
| --- | --- | --- |
| 1 W/m² | BTU/(h&middot;ft²) | 0.31700 |
| 1 W/m² | W/cm² | 0.0001 |
| 1 W/m² | kcal/(h&middot;m²) | 0.85985 |
| 1 BTU/(h&middot;ft²) | W/m² | 3.15459 |
| 1 W/cm² | W/m² | 10,000 |
| 1 W/cm² | BTU/(h&middot;ft²) | 3,171 |
| 1 kcal/(h&middot;m²) | W/m² | 1.163 |

The 0.317 row is the one to memorise, because it turns a solar or HVAC number into US units in a single step. One sun of irradiance, 1,000 W/m², is 317 BTU/(h&middot;ft²), and the solar constant of 1,361 W/m² is 431 BTU/(h&middot;ft²).

### Heat fluxes in real systems

| System | W/m² | W/cm² |
| --- | --- | --- |
| Human body at rest | 55 | 0.0055 |
| Solar constant at Earth orbit | 1,361 | 0.136 |
| Clear-sky noon on the ground | 1,000 | 0.10 |
| Domestic radiator surface | 500–1,000 | 0.05–0.10 |
| Electric stove burner | 150,000 | 15 |
| Rocket nozzle throat | 10^7–10^8 | 1,000–10,000 |

The gap between a radiator and a rocket throat is five orders of magnitude, and it is bridged by the same equation: flux equals temperature difference divided by thermal resistance. A stove burner at 15 W/cm² is why a pan must conduct heat away quickly, and a rocket throat at 10,000 W/cm² is why nozzles are regeneratively cooled rather than simply made thicker.

### Where the conversion bites in practice

- Solar and HVAC data are split between W/m² and BTU/(h&middot;ft²). A window film rated at 200 BTU/(h&middot;ft²) rejects 631 W/m², roughly two-thirds of peak sun.
- Electronics cooling is quoted in W/cm² because a die is small: a 100 W processor on 4 cm² runs at 25 W/cm² and needs a vapour chamber, while 1 W/cm² is fan-cooled territory.
- Fire engineering uses kW/m² for incident flux, so a 50 kW/m² exposure is 5 W/cm² and is enough to ignite wood within minutes.
- Building codes quote U-values in W/(m²&middot;K), not W/m². The flux through a wall is U times the temperature difference, so a U of 0.3 and a 20 K difference give 6 W/m².

The last row is the mistake that matters most. Heat flux in W/m² is a rate at a moment; U-value in W/(m²&middot;K) is a property of an assembly. Multiplying the two together with a temperature difference is the only correct way to get from one to the other, and the units are the reminder.

### Common mistakes

#### Flux is not total heat

A 100 W/m² flux over 10 m² is 1,000 W, and the same flux over 0.1 m² is 10 W. Neither number is more correct; they answer different questions. Sizing a heater needs total power, sizing a surface needs flux, and mixing them produces a design that is wrong by the area ratio.

#### Square feet hide a factor of 10.76

A BTU per hour is small and a square foot is small, so the per-area imperial unit is 3.15 times the SI one, not 10.76 times. Converting area and power separately and then dividing is safe; converting the per-area unit by the area factor alone is not. Check with the solar constant, which is 1,361 W/m² and 431 BTU/(h&middot;ft²).

Time bases cause the other slips. A BTU per hour per square foot is a rate, so a value in BTU/ft² without the per-hour is an energy per area, not a flux. That distinction is invisible in casual writing and decisive in a calculation.

- Divide W/m² by 3.15 to get BTU/(h&middot;ft²): 1,000 W/m² is 317 and the solar constant of 1,361 is 431.
- 1 W/cm² is 10,000 W/m² and 3,171 BTU/(h&middot;ft²), so a 15 W/cm² burner is 150,000 W/m².
- A U-value is not a flux: multiply by the temperature difference, so U 0.3 at 20 K gives 6 W/m².

### Precision and rounding

The W/cm² and kcal factors are exact; the BTU factor is stored rounded to seven figures. Real measurements dominate anyway: a heat-flux sensor is typically good to 3 to 5 percent, and convective coefficients in air vary by more than that between correlations. Two significant figures is often honest for a calculated flux.

Very large fluxes need scientific notation, and the converter handles that. A rocket throat at 10^8 W/m² is 10,000 W/cm² and 31.7 million BTU/(h&middot;ft²), so choose the unit that keeps the number readable and state it explicitly in any report.

## FAQ

### How many W/m2 is 1 BTU per hour per square foot?

3.15459 W/m². The International Table BTU is 1,055.056 J, an hour is 3,600 s and a square foot is 0.09290304 m², which combine to that factor. A 1,000 W/m² sun is 317 BTU/(h&middot;ft²).

### How do I convert 100 W/m2 to BTU?

Divide by 3.15459: 100 W/m² is 31.7 BTU/(h&middot;ft²). That is roughly the flux from a resting human body, about 55 W/m² being a closer figure at basal metabolic rate.

### How many W/m2 is 1 W/cm2?

10,000 W/m². A square centimetre is 10^-4 m², so the flux in W/cm² is the W/m² figure divided by 10,000. A 15 W/cm² stove burner is 150,000 W/m².

### Is heat flux the same as a U-value?

No. Heat flux in W/m² is the actual rate through a surface; a U-value in W/(m²&middot;K) is a property of the assembly. Multiply U by the temperature difference to get flux, so a U of 0.3 and 20 K gives 6 W/m².

### What is the solar constant in BTU?

431 BTU/(h&middot;ft²), from 1,361 W/m² divided by 3.15459. At ground level with a clear sky, about 1,000 W/m² arrives, which is 317 BTU/(h&middot;ft²).

### How do I convert kcal per hour per square metre?

Multiply by 1.163. One kilocalorie per hour is 1.163 W, so a radiator rated at 860 kcal/(h&middot;m²) delivers 1,000 W/m².

### Why do electronics use W/cm2?

Because dies are small and the numbers stay readable. A 100 W chip on 4 cm² is 25 W/cm², a flux that needs a vapour chamber, while 1 W/cm² can be handled by a fan and heatsink.

### How much heat flux ignites wood?

About 10 to 20 kW/m² sustained, which is 1 to 2 W/cm². Piloted ignition comes faster at 30 to 50 kW/m², and fire codes often test at 50 kW/m².

### Does heat flux depend on temperature?

Yes, through the driving temperature difference and the heat-transfer coefficient. Radiative flux scales with the fourth power of absolute temperature, so doubling surface temperature multiplies it by sixteen.

## Method and sources

Methodology: Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: 2026-11-19.
- Linear conversion through W/m²: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 BTU/(h·ft²) = 3.15459 W/m²; 1 W/cm² = 10000 W/m²; 1 kcal/(h·m²) = 1.163 W/m².
- Watts per square centimetre is an exact power of ten, and 1 kcal/(h·m²) = 1.163 W/m² exactly from the International Table calorie (4.1868 J). The BTU per hour-square foot uses the International Table BTU and the international foot and is stored rounded.
- The SI prefixes are exact; the BTU/(h·ft²) factor is stored as a rounded decimal, the largest deviation being 2.4e−5% relative. A result carries that rounding on top of floating-point arithmetic.