slug: electrical-power-converter
title: "Electrical Power Converter"
category: unit
updated: 2026-11-19
canonical: https://calcseed.com/c/unit/electrical-power-converter/
html: /c/unit/electrical-power-converter/
---

# Electrical Power Converter

Convert electrical power between watts, milliwatts, kilowatts, megawatts, gigawatts and horsepower.

## Quick answer

**Electrical power converter** — 1 kW = 1,000 W, and 1 hp = 745.7 W.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Value | 100 |  |
| From | kw |  |
| To | hp |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Result | 134.102 |  |

## Formula

```text
result = value × factor(from) ÷ factor(to), with 1 W = 1, 1 mW = 0.001 W, 1 kW = 1,000 W, 1 MW = 1,000,000 W, 1 GW = 1,000,000,000 W and 1 hp = 745.699872 W
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Value | number |  | 100 |
| From | select |  | kw |
| To | select |  | hp |

## Outputs

| Result | Format |
| --- | --- |
| Result | primary |
| Result | unit |

## How it works

### What this converter does

Enter a power figure, choose the unit it is rated in and the unit you want, and the tool converts it. The range runs from milliwatts to gigawatts, with mechanical horsepower on the same scale. At the defaults it converts **100 kW** to **134.1 hp**, the rating a 134 hp motor would carry on a US nameplate.

### The conversion formula

The watt is the SI derived unit of power: one joule per second, or one ampere at one volt. Every prefix on the ladder is decimal, so a kilowatt is 1,000 W and a gigawatt is a billion watts. Moving three steps up the ladder, from kW to GW, multiplies by a million.

Horsepower is not a prefix but an entirely separate unit. Mechanical horsepower was fixed at 550 foot-pounds per second, which converts to 745.699872 W. That makes 1 kW equal 1,000 ÷ 745.699872 = 1.34102 hp, and 100 kW equal 134.1 hp.

### Worked example: 100 kW

The default run is 100 × 1,000 ÷ 745.699872 = **134.1 hp**. The same motor in megawatts is 100 ÷ 1,000 = **0.1 MW**, and in watts 100,000 W. Going the other way, a 100 hp motor draws 100 × 745.699872 ÷ 1,000 = **74.57 kW** at full load.

#### What a motor actually draws

Shaft horsepower and input power are not the same number. A 100 hp motor at 95% efficiency draws 74.57 ÷ 0.95 = 78.5 kW at full load, and about 66.7 kW at 85% load. Divide the input power by the power factor to get the apparent power that the cable must carry, which is why feeds are sized above the shaft rating.

### Power ratings from appliance to plant

| Load | kW | hp | Notes |
| --- | --- | --- | --- |
| LED bulb | 0.01 | 0.013 | 10 W draw |
| Laptop under load | 0.065 | 0.087 | 65 W supply |
| Electric kettle | 1.5 | 2.01 | boils 1 L in 3 min |
| EV home charger | 7.4 | 9.92 | 32 A at 240 V |
| House at peak | 10 | 13.4 | AC plus oven |
| Wind turbine | 3,000 | 4,023 | 3 MW nameplate |
| Gas plant unit | 500,000 | 670,500 | 500 MW |
| Nuclear unit | 1,000,000 | 1.34 million | 1 GW |

The hp column is the kW figure times 1.34102 every time. A 3 MW turbine is 3,000 kW × 1.34102 = 4,023 hp, and a 1 GW reactor is 1,341,022 hp. Those large hp numbers are rarely used in practice, which is why plant ratings stay in MW and GW.

### Where the scale jumps cause errors

- Two prefixes instead of one. A 500 MW plant is 0.5 GW, not 500 GW, and writing GW where MW is meant inflates output a thousandfold.
- Horsepower from a different standard. Metric horsepower (PS) is 735.5 W, so 100 PS is 73.55 kW, about 1.4% below 100 mechanical hp.
- Watts against watt-hours. A 1 kW heater uses 1 kWh in one hour; the converter handles power only, not energy.
- Milliwatts treated as watts. A 5 mW laser pointer is 0.005 W, not 5 W, and the difference is the gap between a cat toy and a hazard.

### Sizing a supply from a power figure

Convert to kW first, then divide by voltage for current. A 7.4 kW charger at 240 V draws 30.8 A, which needs a 40 A breaker at 80% derating. A 1.5 kW kettle at 120 V draws 12.5 A and runs happily on a 15 A circuit. The arithmetic is amps = watts ÷ volts, so keeping power in watts avoids a factor-of-1,000 mistake.

Three-phase supplies split the same power across three conductors, so the current per phase is lower. A 100 kW load at 400 V three-phase draws 100,000 ÷ (1.732 × 400) = 144 A, against 250 A on a single-phase 400 V feed. That is the practical reason industrial equipment above about 7.5 kW is usually specified three-phase.

#### How many homes one gigawatt serves

The average US home draws about 1.2 kW continuously, so 1 GW covers roughly 830,000 homes at average load. Peak demand is three to five times higher per home, which is why utilities size generation against peaks near 5–10 kW per house rather than annual averages. A 500 MW plant therefore serves a city of about 100,000 homes at peak, not 400,000.

### Mistakes worth avoiding

- Using 746 W for horsepower when more precision is needed. The exact figure is 745.699872 W, a 0.04% difference that matters on a 10 MW machine.
- Adding kW and hp in the same column. Convert everything to one unit before summing a load list.
- Reading a generator nameplate as continuous output. Standby ratings are often 10% above prime ratings.
- Assuming power factor of 1 for motors. At 0.85 the kVA draw is 18% higher than the kW figure.

Data-centre load lists show why unit discipline matters. A 30 MW hall is 30,000 kW, which at 1.34102 is 40,231 hp, a figure no electrical engineer would use. Keep the mechanical rating in hp for rotating plant and the electrical rating in kW or MW for distribution, and convert only when the two meet on one document.

### Precision and rounding

Appliance ratings carry two significant figures at best, so 1.5 kW is not 1.500 kW. Plant ratings are firmer, quoted to the nearest MW. Carry the conversion to four figures and round at the end: 100 kW to hp rounds to 134.1, and reporting 134.102 suggests a precision the nameplate does not have.

#### A quick sanity check

Remember two anchors: 1 hp is about 0.75 kW and 1 kW is about 1.34 hp. Any conversion that moves the number by a factor of 100 or more means a prefix slipped. A 100 kW motor reported as 13.4 hp has lost a factor of 10, and one reported as 1,341 hp has gained one.

## FAQ

### How many watts are in a kilowatt?

Exactly 1,000 W, so 100 kW is 100,000 W.

### How do I convert kW to hp?

Multiply by 1.34102. So 100 kW is 134.1 hp and 7.4 kW is 9.92 hp.

### How many megawatts are in a gigawatt?

Exactly 1,000 MW, so a 500 MW plant is 0.5 GW.

### How many watts is 1 horsepower?

Exactly 745.699872 W, so 1 kW is 1.34102 hp.

### How many homes does 1 GW power?

About 830,000 at average US load of 1.2 kW, or 100,000–200,000 at peak demand.

### How many kW is a 3 MW wind turbine in horsepower?

4,023 hp, from 3,000 kW × 1.34102.

### How many watts is 5 mW?

0.005 W, since a milliwatt is one thousandth of a watt.

### Is a kWh the same as a kW?

No. A kW is power and a kWh is energy: a 1 kW load running for one hour uses 1 kWh.

### How many amps does a 7.4 kW charger draw?

30.8 A at 240 V, from 7,400 W ÷ 240 V, which calls for a 40 A breaker.

## Method and sources

Methodology: Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: 2026-11-19.
- SI derived unit: watt.
- Mechanical horsepower: 745.699872 W.