# Electrical Load Calculator

Add up the wattage of all appliances on a circuit and convert the total load to amps for a given voltage.

## Quick answer

**Quick answer:** with the default inputs (2,000 W, 120), the load current is **16.67**. At these inputs: recommended breaker = **25**. Change any input to update the result.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Total connected wattage | 2000 | W |
| Voltage | 120 |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Load current | 16.6667 |  |
| Recommended breaker | 25 |  |

## Formula

```text
amps = watts ÷ volts
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Total connected wattage | number | W | 2000 |
| Voltage | select |  | 120 |

## Outputs

| Result | Format |
| --- | --- |
| Load current | primary |
| Load current | number |
| Recommended breaker | number |

## How it works

### What this calculator does

Add up the nameplate wattage of everything on a circuit, and this calculator converts the total into amps and then into the breaker size the load calls for. At the defaults — **2,000 W at 120 V** — the load is **16.67 amps**, and after the 125% continuous-load factor the calculator recommends a **25 A breaker**.

### How the formula works

Watts divided by volts leaves amps — the current the wiring actually carries. The same 2,000 W load draws 16.67 A on a 120 V circuit but only **8.33 A at 240 V**, which is why water heaters, dryers and ranges get dedicated 240 V circuits: they move double the watts through the same copper.

The second step is code, not arithmetic. NEC 210.20(A) sizes branch-circuit conductors and breakers at **125% of the continuous load** — equivalently, a load may use only 80% of a breaker&rsquo;s rating if it runs three hours or more. The calculator multiplies the load amps by 1.25 and rounds up to the next standard breaker size (15, 20, 25, 30, 35, 40 A and so on). For the default 16.67 A load: 16.67 × 1.25 = 20.83 A, which rounds up to **25 A**.

#### Worked example at the defaults

Suppose a circuit feeds a 1,200 W microwave, a 500 W freezer and a 300 W router-and-modem shelf — 2,000 W connected. On 120 V that is **2,000 ÷ 120 = 16.67 A**. Because the freezer runs continuously, the 1.25 factor applies: 20.83 A required, so a 25 A breaker on 10 AWG wire is the correct assembly. A 20 A breaker would also carry 16.67 A momentarily, but a 100% continuous 16.67 A load exceeds the 16 A continuous limit (80% of 20 A) that 20 A allows.

### Typical appliance wattage

| Appliance | Typical draw |
| --- | --- |
| Microwave | 1,000–1,500 W |
| Space heater | 750–1,500 W |
| Hair dryer | 1,200–1,800 W |
| Window AC | 500–1,500 W |
| Toaster oven | 1,200–1,800 W |
| Refrigerator (running) | 150–300 W |

Two of these on one circuit already approach its limit: a 1,500 W space heater and a 1,500 W microwave together draw 25 A — more than a 20 A circuit can carry at any duration, and more than double what a 15 A circuit allows continuously.

### The 15 A and 20 A circuits in your walls

Most residential receptacle circuits are 15 A or 20 A, and the wire gauge is locked to the breaker: **14 AWG copper tops out at 15 A, and 12 AWG copper at 20 A**. In practical watt terms at 120 V, a 15 A circuit delivers 1,800 W but only **1,440 W continuous** (80% rule), and a 20 A circuit delivers 2,400 W with a **1,920 W continuous** limit. If your connected wattage exceeds the continuous limit, the fix is load splitting — moving the heater to another circuit — not simply swapping in a bigger breaker, which the wire gauge forbids.

#### Continuous versus intermittent loads

- Continuous loads (three hours or more): limited to 80% of the breaker rating — 1,440 W on 15 A, 1,920 W on 20 A.
- Intermittent loads (hair dryer, kettle, microwave bursts): may briefly use the full rating, but non-simultaneous use is your responsibility, not the breaker&rsquo;s.
- Motor loads (freezers, saws, pumps) draw a starting surge 2–4 times their running current, which is why dedicated circuits and time-delay breakers exist.

### What affects the number

- Voltage — 240 V circuits carry double the watts for the same amps
- Motor loads that spike briefly when starting
- Continuous versus intermittent duty
- Ambient temperature derating in hot spaces — conductors in areas above 86&deg;F must be derated per NEC tables
- Power factor on motor-driven appliances, which makes real amps slightly higher than watts ÷ volts suggests

### Common mistakes when adding up loads

- Reading the surge rating instead of the running rating — a compressor appliance lists both; use the running watts and add 25–50% headroom for starts.
- Counting every plug at once — the load that matters is what runs simultaneously, not everything that could.
- Assuming a bigger breaker fixes nuisance trips; if the wire is 14 AWG, a 15 A breaker is the legal maximum regardless of the load math.
- Forgetting 240 V appliances entirely — they belong on their own circuits and never share with the 120 V tally.
- Adding a second large appliance to a bathroom or kitchen small-appliance circuit, which code reserves for dedicated 20 A service.

### When the answer means a new circuit

If the recommended breaker comes back larger than the wire can legally carry — 15 A for 14 AWG, 20 A for 12 AWG — the honest fix is a new circuit, not a breaker swap. A single 20 A, 120 V circuit costs roughly $150–$300 to run from a nearby panel in an unfinished basement and $300–$500 through finished walls in 2026. Permanent high-wattage appliances — space heaters over 1,500 W, hot tubs, EV chargers, ranges — should get dedicated circuits by design rather than by negotiation with an existing breaker. Anything involving panel work, AFCI/GFCI requirements or unknown wiring history belongs with a licensed electrician; the calculator tells you what the load demands, and the electrician tells you what the wall actually holds.

## FAQ

### How many watts on a 15 amp circuit?

A 15 A circuit at 120 V delivers up to 1,800 W, though continuous loads are limited to 80% of that, or 1,440 W.

### How many watts on a 20 amp circuit?

A 20 A circuit at 120 V delivers 2,400 W maximum and 1,920 W for continuous loads under the 80% rule.

### What breaker do I need for a 2,000 W load?

At 120 V the load is 16.67 A. With the 125% continuous factor that is 20.83 A, which rounds up to a 25 A breaker — on wire rated for it, such as 10 AWG. On standard 12 AWG the practical fix is splitting the load across two 20 A circuits.

### What is the 80% rule for breakers?

Continuous loads should not exceed 80% of the breaker rating to prevent overheating, so a 20 A circuit safely serves 1,920 W continuous and a 15 A circuit serves 1,440 W.

### How do I find an appliance wattage?

Check the nameplate label, which lists watts or amps and volts; watts equals amps times volts. For a 120 V appliance drawing 5 A, that is 600 W.

### Can I run a heater and a microwave together?

Only if their combined watts stay under the circuit limit. A 1,500 W heater plus a 1,500 W microwave is 3,000 W — 25 A at 120 V, well past any standard receptacle circuit.

### How many outlets can be on one circuit?

There is no fixed count in residential code; the limit is total load, so tally the wattage of everything plugged in rather than the outlets.

### Why did the calculator recommend a 25 A breaker for 16.67 A?

NEC sizing applies 125% to continuous loads: 16.67 × 1.25 = 20.83 A, and the next standard breaker above that is 25 A. This mirrors the 80% continuous limit from the breaker side.

### What wire gauge matches each breaker size?

14 AWG copper pairs with 15 A breakers and 12 AWG with 20 A breakers on standard residential branch circuits. Larger breakers need 10 AWG (30 A) or heavier — never upsize a breaker beyond what the wire allows.

### How many amps does a 1,500 W space heater draw?

1,500 ÷ 120 = 12.5 A, which is why a heater alone occupies most of a 15 A circuit (1,440 W continuous) and must run alone on it.

## Method and sources

Methodology: Cost ranges reflect 2026 U.S. national averages for materials and labor; regional pricing varies, so use results as a planning baseline and confirm with local quotes.

Last updated: 2026-11-17.
- Power (W) = voltage (V) × current (A); NEC 80% continuous-load limit and standard breaker sizes.