slug: electric-resistance-converter
title: "Electric Resistance Converter"
category: unit
updated: 2026-11-19
canonical: https://calcseed.com/c/unit/electric-resistance-converter/
html: /c/unit/electric-resistance-converter/
---

# Electric Resistance Converter

Convert resistance between ohms, milliohms, kilo-ohms and megaohms.

## Quick answer

**Electric Resistance Converter** — convert between Ohm (Ω), Milliohm (mΩ), Kilo-ohm (kΩ) and more.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Value | 1 |  |
| From | kohm |  |
| To | ohm |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Result | 1000 |  |

## Formula

```text
result = value × factor_from_ ÷ factor_to_  &middot;  1 m&Omega; = 0.001 &Omega;  &middot;  1 k&Omega; = 1,000 &Omega;  &middot;  1 M&Omega; = 1,000,000 &Omega;
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Value | number |  | 1 |
| From | select |  | kohm |
| To | select |  | ohm |

## Outputs

| Result | Format |
| --- | --- |
| Result | primary |
| Result | unit |

## How it works

### What an ohm measures

An ohm is the resistance that lets one ampere flow when one volt is applied, which makes it one volt per ampere. Every unit in this converter is a decimal prefix of that: milliohms for shunts and contact resistance, kilo-ohms for signal resistors, mega-ohms for insulation. At the defaults the tool converts 1 k&Omega; into 1,000 &Omega;.

### The conversion formula

There is no measured constant anywhere in the chain, so every conversion is a movement of the decimal point. Milli is 10^-3, kilo is 10^3 and mega is 10^6; three decades separate each step, which is why a resistor read on the wrong range is wrong by exactly a factor of 1,000.

The prefixes also stack against the ohm law in a tidy way. Because the ohm is defined by volts and amperes rather than by a physical artefact, converting resistance never changes a circuit&rsquo;s behaviour; it only changes how the number is written. A 4.7 k&Omega; resistor and a 4,700 &Omega; resistor are the same part.

### Worked example: 1 kilo-ohm

At the defaults the value is 1 and the units run from k&Omega; to &Omega;: 1 × 1,000 ÷ 1 = **1,000 &Omega;**. With 5 V across it, the current is 5 ÷ 1,000 = 5 mA, and the power is 5 V × 5 mA = 25 mW, which is comfortably inside a quarter-watt part.

Express the same part two other ways: 0.001 M&Omega; and 1,000,000 m&Omega;. Neither changes the resistor, but writing 1 M&Omega; by mistake does change the circuit, because that is a thousand times more resistance and the current falls to 5 &micro;A.

### Resistance conversions at a glance

| From | To unit | Multiply by |
| --- | --- | --- |
| 1 &Omega; | m&Omega; | 1,000 |
| 1 &Omega; | k&Omega; | 0.001 |
| 1 &Omega; | M&Omega; | 0.000001 |
| 1 k&Omega; | &Omega; | 1,000 |
| 1 k&Omega; | M&Omega; | 0.001 |
| 1 M&Omega; | k&Omega; | 1,000 |
| 1 m&Omega; | &Omega; | 0.001 |

Engineers compress these rows into shorthand: 4R7 means 4.7 &Omega;, 4k7 means 4,700 &Omega; and 4M7 means 4.7 M&Omega;. The letter sits where the decimal point belongs, which survives bad photocopies in a way that a small dot never does. Reading 4k7 as 4.7 &Omega; is a thousand-fold error and one of the commonest bench mistakes.

### Resistances you actually meet

| Item | Typical value | In ohms |
| --- | --- | --- |
| Current shunt | 0.1 &Omega; | 100 m&Omega; |
| Loudspeaker | 4–8 &Omega; | 4–8 |
| Signal resistor | 4.7 k&Omega; | 4,700 |
| Pull-up resistor | 10 k&Omega; | 10,000 |
| Dry skin contact | 100 k&Omega; | 100,000 |
| Insulation test pass | >1 M&Omega; | >1,000,000 |

The shunt row is where milliohms earn their place: a 0.1 &Omega; shunt carrying 10 A drops 1 V and dissipates 10 W, so the value is small enough not to disturb the circuit but large enough to measure. The skin row is why 100 k&Omega; appears in electrical-safety standards as the threshold below which a shock becomes dangerous.

### Where the conversion bites in practice

- Multimeter ranges step by decades: 200 &Omega;, 2 k&Omega;, 20 k&Omega;, 200 k&Omega;, 2 M&Omega;. A reading of 0.47 on the 20 k&Omega; range is 470 &Omega;, not 0.47 &Omega;, and the decimal point does not tell you which.
- Wire resistance follows R = &rho;L/A. A 1 mm² copper conductor is about 17 m&Omega; per metre, so a 30 m run in a 1.5 mm² cable adds roughly 0.34 &Omega; — negligible at 10 A, significant for a 4–20 mA loop.
- Insulation resistance is specified in M&Omega; and falls with moisture. A motor that reads 2 M&Omega; dry can read 0.2 M&Omega; after a humid week, and standards usually fail anything below 1 M&Omega;.
- Contact resistance in relays and connectors is quoted in m&Omega;. A 50 m&Omega; contact at 20 A dissipates 20 W, which is enough to weld a cheap relay shut.

The habit that prevents most of these errors is to convert to ohms in your head before doing any circuit arithmetic. Ohm law only works cleanly in base units, so 4.7 k&Omega; with 5 V becomes 5 ÷ 4,700 = 1.06 mA, not 5 ÷ 4.7 = 1.06 A.

### Common mistakes

#### M and m are a factor of a billion apart

Upper-case M is mega, 10^6; lower-case m is milli, 10^-3. A 1 M&Omega; resistor is 1,000,000 &Omega; while a 1 m&Omega; resistor is 0.001 &Omega;, so the typographical difference covers nine decades. Schematics avoid the ambiguity by writing meg for mega and by using the R-notation for milliohms.

#### Resistance is not resistivity

Resistance in ohms depends on the object; resistivity in ohm-metres depends on the material. A short fat copper bar and a long thin one can both be 1 &Omega; while sharing a resistivity of 1.68 × 10^-8 &Omega;&middot;m. Converting between k&Omega; and M&Omega; stays inside the first concept and never touches the second.

The other recurring slip is treating a resistor&rsquo;s nominal value as its actual value. A 5 percent 4.7 k&Omega; part can measure anywhere from 4,465 to 4,935 &Omega;, so a reading of 4,600 &Omega; is in tolerance rather than wrong. Check the tolerance band before you convert anything.

- Upper-case M is mega and lower-case m is milli: 1 M&Omega; is 1,000,000 &Omega; while 1 m&Omega; is 0.001 &Omega;, nine decades apart.
- 4k7 means 4,700 &Omega; and 4R7 means 4.7 &Omega;, so read the letter in the middle rather than the digits around it.
- A 5 percent 4.7 k&Omega; part measures anywhere from 4,465 to 4,935 &Omega;, so a 4,600 &Omega; reading is in tolerance and not a fault.

### Precision and rounding

All factors are exact powers of ten, so the converter adds no error. The measurement dominates: a 3.5-digit meter resolves 0.1 &Omega; on its lowest range, and lead resistance of 0.2 &Omega; is often larger than the resistor being tested, which is why four-wire Kelvin measurement exists for anything below 1 &Omega;.

For high values the limit is the meter again. A 10 M&Omega; resistor on a 20 M&Omega; range reads with a few percent uncertainty, and surface contamination on the board can dominate. Convert units freely, but treat the last digit of any megohm reading as decoration.

## FAQ

### How many ohms are in 1 kilo-ohm?

Exactly 1,000. The kilo prefix is 10^3, so 4.7 k&Omega; is 4,700 &Omega; and 0.1 k&Omega; is 100 &Omega;. The factor is a decimal shift with no rounding.

### How many kilo-ohms is 1 mega-ohm?

1,000. Mega is 10^6 and kilo is 10^3, so one mega-ohm is a thousand kilo-ohms, or a million ohms. An insulation reading of 2 M&Omega; is 2,000 k&Omega;.

### What does 4R7 mean on a resistor?

4.7 ohms. The R marks the decimal point, so 4k7 is 4,700 &Omega; and 4M7 is 4.7 M&Omega;. The convention survives poor print quality where a small dot would vanish.

### How many milliohms is 1 ohm?

1,000. Milliohms are used for current shunts, contact resistance and wire resistance: a 1 mm² copper conductor measures about 17 m&Omega; per metre.

### How much current flows through 1 k ohm at 5 V?

5 mA, from I = V/R = 5 ÷ 1,000. The resistor dissipates 25 mW, well within a standard quarter-watt part.

### Why does my meter show 0.47 on the 20k range?

That is 470 &Omega;. The range multiplies the displayed number by 1,000, so 0.47 on the 20 k&Omega; setting is 0.47 × 1,000. Always check the range before reading the digits.

### What insulation resistance should a motor have?

Above 1 M&Omega; for most low-voltage equipment, with readings above 100 M&Omega; when new and dry. Moisture can pull a healthy 2 M&Omega; winding down to 0.2 M&Omega; within a week.

### Is resistance the same as impedance?

No. Resistance applies to direct current and dissipates power; impedance extends it to alternating current and includes reactance from capacitors and inductors. Both are measured in ohms, so the unit conversion is identical.

### How do I convert 10 M ohm to ohms?

Multiply by 1,000,000: 10,000,000 &Omega;, sometimes written 10 M&Omega; or 1 × 10^7 &Omega;. A 10 M&Omega; resistor draws only 1.2 &micro;A at 12 V.

## Method and sources

Methodology: Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: 2026-11-19.
- Linear conversion through Ω: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 Milliohm (mΩ) = 0.001 Ω; 1 Kilo-ohm (kΩ) = 1000 Ω; 1 Megaohm (MΩ) = 1000000 Ω.
- Every factor is an exact decimal SI prefix of the base unit, so no rounded constant is involved.
- Every factor is an exact definition or an exact decimal SI prefix, so the only error is the floating-point rounding of the arithmetic itself.