slug: dynamic-viscosity-converter
title: "Dynamic Viscosity Converter"
category: unit
updated: 2026-11-19
canonical: https://calcseed.com/c/unit/dynamic-viscosity-converter/
html: /c/unit/dynamic-viscosity-converter/
---

# Dynamic Viscosity Converter

Convert dynamic viscosity between Pa·s, centipoise and poise.

## Quick answer

**Dynamic Viscosity Converter** — convert between Pascal-second (Pa·s), Centipoise (cP), Poise (P) and more.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Value | 0.001 |  |
| From | Pa.s |  |
| To | cP |  |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Result | 1 |  |

## Formula

```text
result = value × factor_from_ ÷ factor_to_  
1 cP = 1 mPa&middot;s = 0.001 Pa&middot;s &#183; 1 P = 0.1 Pa&middot;s &#183; 1 lb/(ft&middot;s) = 0.45359237 ÷ 0.3048 = 1.488164 Pa&middot;s
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Value | number |  | 0.001 |
| From | select |  | Pa.s |
| To | select |  | cP |

## Outputs

| Result | Format |
| --- | --- |
| Result | primary |
| Result | unit |

## How it works

### What this converter returns

Dynamic viscosity is the shear stress a fluid develops per unit strain rate, and it is the number that enters a pressure-drop or a bearing calculation directly. This tool converts across four units: Pa&middot;s, centipoise, poise and lb/(ft&middot;s). The default is **0.001 Pa&middot;s** into cP, which returns **1 cP**, the viscosity of water at 20 &deg;C.

### Where the four factors come from

The poise is the CGS unit, defined as one dyne-second per square centimetre, which works out to exactly 0.1 Pa&middot;s. The centipoise is one hundredth of that, 0.001 Pa&middot;s, and 0.001 Pa&middot;s is also one millipascal-second. So cP and mPa&middot;s are the same unit, just as cSt and mm²/s are the same in kinematic viscosity. Because water sits at 1 cP at room temperature, the centipoise is a convenient yardstick.

The US unit divides a pound by a foot and a second. One pound is 0.45359237 kg and one foot is 0.3048 m, so 0.45359237 ÷ 0.3048 = 1.488164 Pa&middot;s. Unlike the kinematic case there is no density term, so the factor is a clean ratio of mass to length. The stored six digits carry a relative error of 3.8 × 10^−6%, small enough to ignore in any pump calculation.

#### Dynamic and kinematic are linked by density

The relation is &mu; = &nu; &middot; &rho;. Water at 20 &deg;C has a kinematic viscosity of 1.002 cSt and a density of 998 kg/m³, so its dynamic viscosity is 1.002 × 10^−6 × 998 = 0.001 Pa&middot;s, or 1 cP. That is not a coincidence: the centipoise was effectively set so water reads 1 at room temperature.

### Worked example at the default settings

Take 0.001 Pa&middot;s into cP. The arithmetic is 0.001 × 1 ÷ 0.001 = **1 cP**. Into poise it is 0.001 ÷ 0.1 = 0.01 P, and into lb/(ft&middot;s) it is 0.001 ÷ 1.488164 = 0.000672, a value no US datasheet would print because water is not measured in that unit.

| Fluid | Pa&middot;s | cP | lb/(ft&middot;s) |
| --- | --- | --- | --- |
| Air (20 &deg;C) | 0.0000181 | 0.0181 | 0.0000122 |
| Water (20 &deg;C) | 0.001 | 1.0 | 0.000672 |
| Blood (37 &deg;C) | 0.0035 | 3.5 | 0.00235 |
| Motor oil (40 &deg;C) | 0.15 | 150 | 0.101 |
| Honey | 5 | 5,000 | 3.36 |
| Peanut butter | 250 | 250,000 | 168 |

The range from air at 0.018 cP to peanut butter at 250,000 cP is seven orders of magnitude, far wider than the kinematic table because density no longer normalizes the extremes. A gas and a paste differ in density by perhaps a factor of 1,000 but in dynamic viscosity by ten million, which is why one unit cannot describe both without a prefix.

### Where dynamic viscosity decides an outcome

- Pipe pressure drop: laminar flow gives &Delta;P = 32&mu;Lv ÷ D², so doubling &mu; doubles the loss, and 150 cP oil needs about 150 times the pressure of water at the same rate.
- Bearing design: the Sommerfeld number uses &mu; directly, and a drop from 0.15 to 0.02 Pa&middot;s at operating temperature thins the oil film by a factor of seven.
- Stirring and mixing: impeller power scales with &mu; in the laminar regime, so a 10 Pa&middot;s paste needs a different agitator, not a bigger motor on the same one.
- Blood rheology: plasma at 1.2 cP and whole blood at 3.5 cP differ by three times, and that ratio sets the pressure the heart must supply.
- Coating: blade and roll coaters control wet film by &mu; and speed together, and a 20% viscosity drift shows up as a coat-weight change.

The blood row is a good sanity check on units people meet in two forms. A haematocrit report may say whole blood is 3.5 cP at 37 &deg;C, while a paper on plasma substitutes quotes 1.2 mPa&middot;s. Those are 3.5 cP and 1.2 cP, because mPa&middot;s and cP are identical, and the threefold difference is real physiology rather than a unit slip.

#### Newtonian and non-Newtonian fluids

Every conversion here assumes a Newtonian fluid, where viscosity does not change with shear rate. Peanut butter at 250 Pa&middot;s is not Newtonian: stir it and the apparent viscosity falls, which is why the 250 figure is a single-shear-rate measurement rather than a constant. Paint, ketchup and blood at low shear all behave the same way, and a converter cannot fix a rheology that needs a flow curve.

### Mistakes that shift the number

- Confusing poise with centipoise: the factor is 100, so 1.5 P is 150 cP, not 1.5 cP.
- Using Pa&middot;s where cP is meant on a datasheet: 0.15 Pa&middot;s is 150 cP, a 1,000-fold difference in the printed figure.
- Treating kinetic viscosity as interchangeable: kinematic is dynamic divided by density, so the two differ by about 15% for oil and 0.1% for water.
- Ignoring temperature: motor oil falls from roughly 300 cP at 20 &deg;C to 150 at 40 &deg;C and 20 at 100 &deg;C, a fifteenfold swing.

The temperature point dominates real designs. A bearing selected on the 40 &deg;C figure will run at 100 &deg;C and find one-seventh of the viscosity it was designed for, which is why oil grades are chosen on hot viscosity and why oil coolers exist at all. The conversion tool tells you what 20 cP is in Pa&middot;s; it cannot tell you which temperature the 20 refers to.

### Precision and rounding

Three of the four factors are exact and the US factor is good to six digits, so the conversion itself is not the weak link. A rotational viscometer is good to 1–2% and a capillary tube to 0.5%, and non-Newtonian fluids are worse. Report 1.0 cP for water and 150 cP for oil, not 150.000, because the third digit is already optimistic.

A property and an observation are easy to confuse. A falling-ball viscometer reports a terminal velocity in mm/s, and reaching Pa&middot;s from there runs through Stokes law with the ball radius and the density difference. A figure in cP is the fluid property; a figure in mm/s is what the instrument happened to measure, and only one of them belongs in a datasheet.

#### A pump power check

Pumping power is roughly Q &middot; &Delta;P, and &Delta;P itself is proportional to &mu; in laminar flow. Moving 1 L/s of 150 cP oil through 10 m of 20 mm pipe gives a velocity of 3.18 m/s and &Delta;P = 32 × 0.15 × 10 × 3.18 ÷ 0.0004 = 382 kPa, so the hydraulic power is 0.001 × 382,000 = 382 W. The same line with water gives 2.55 kPa and 2.55 W, a 150-fold difference that follows directly from the viscosity ratio.

## FAQ

### How do I convert Pa&middot;s to cP?

Multiply by 1,000. Water at 0.001 Pa&middot;s is 1 cP, and a 0.15 Pa&middot;s oil is 150 cP.

### How many poise are in 1 Pa&middot;s?

Exactly 10. The poise is 0.1 Pa&middot;s, so 0.15 Pa&middot;s is 1.5 P and 1 Pa&middot;s is 10 P.

### Is 1 cP the same as 1 mPa&middot;s?

Yes, exactly. A centipoise is 0.001 Pa&middot;s and a millipascal-second is also 0.001 Pa&middot;s, so the two are interchangeable.

### What is the viscosity of water?

About 0.001 Pa&middot;s at 20 &deg;C, which is 1 cP. It falls to 0.00065 Pa&middot;s at 40 &deg;C and 0.00028 Pa&middot;s at 100 &deg;C.

### How do I convert cP to lb/(ft&middot;s)?

Divide by 1,488.16. A 150 cP oil is 0.1008 lb/(ft&middot;s), because 1 lb/(ft&middot;s) is 1.488164 Pa&middot;s.

### What is the difference between dynamic and kinematic viscosity?

Dynamic viscosity is shear stress per strain rate in Pa&middot;s; kinematic is dynamic divided by density in m²/s. Water at 20 &deg;C is 1 cP and 1 cSt, but oil at 850 kg/m³ differs by that density factor.

### How viscous is honey in cP?

Around 5,000 cP at room temperature, which is 5 Pa&middot;s. Peanut butter is far higher at roughly 250,000 cP, and both are non-Newtonian.

### Why does my pump need more power than the datasheet says?

The datasheet usually assumes water at 1 cP. A 150 cP fluid needs about 150 times the pressure drop in laminar flow, so a 2.5 W duty becomes 382 W.

### Does temperature change dynamic viscosity much?

Yes, far more than most properties. Motor oil falls from about 300 cP at 20 &deg;C to 150 cP at 40 &deg;C and 20 cP at 100 &deg;C, a fifteenfold drop across the operating range.

## Method and sources

Methodology: Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: 2026-11-19.
- Linear conversion through Pa·s: result = value × factor(from) ÷ factor(to).
- Factors applied: 1 Centipoise (cP) = 0.001 Pa·s; 1 Poise (P) = 0.1 Pa·s; 1 lb/(ft·s) = 1.488164 Pa·s.
- The poise and centipoise are exact CGS definitions (1 P = 0.1 Pa·s). The pound per foot-second follows from the international pound and foot and is stored rounded.
- The SI prefixes are exact; the lb/(ft·s) factor is stored as a rounded decimal, the largest deviation being 3.8e−6% relative. A result carries that rounding on top of floating-point arithmetic.