# Combined Gas Law Calculator

Solve the combined gas law P₁V₁/T₁ = P₂V₂/T₂ for any one of its six quantities. Free and instant.

## Quick answer

**Quick answer:** with the default inputs (100 kPa, 2 L, 300 K, 200 kPa), the final volume is **1 L**. Change any input to update the result.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Initial pressure | 100 | kPa |
| Initial volume | 2 | L |
| Initial temperature | 300 | K |
| Final pressure | 200 | kPa |
| Final temperature | 300 | K |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Final volume | 1 | L |

## Formula

```text
P₁V₁/T₁ = P₂V₂/T₂
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Initial pressure | number | kPa | 100 |
| Initial volume | number | L | 2 |
| Initial temperature | number | K | 300 |
| Final pressure | number | kPa | 200 |
| Final volume | number | L | 1 |
| Final temperature | number | K | 300 |

## Outputs

| Result | Format |
| --- | --- |
| Final volume | primary |

## How it works

### Six inputs, one invariant

This calculator takes two full states of a sealed gas sample and returns whichever of the six values you leave out. The invariant is P×V ÷ T, which stays the same from the first state to the second as long as nothing leaks and no reaction consumes gas. The default output is the final volume in litres.

Solve for any single unknown by cross-multiplying and dividing by what is left. For the final volume the rearrangement is V&sub2; = P&sub1;V&sub1;T&sub2; ÷ (T&sub1;P&sub2;), and the other five follow the same pattern with the subscripts moved around.

Temperature has to be absolute in kelvin. Pressure and volume only have to be consistent with themselves — kPa with litres is fine, atm with litres is fine, and mixing the two pressure units across the two states is not.

### The three laws it absorbs

| Held constant | Law | Relation |
| --- | --- | --- |
| Temperature | Boyle&rsquo;s law | P&sub1;V&sub1; = P&sub2;V&sub2; |
| Pressure | Charles&rsquo;s law | V&sub1;/T&sub1; = V&sub2;/T&sub2; |
| Volume | Gay-Lussac&rsquo;s law | P&sub1;/T&sub1; = P&sub2;/T&sub2; |
| Nothing | Combined gas law | P&sub1;V&sub1;/T&sub1; = P&sub2;V&sub2;/T&sub2; |

Each special case is the combined law with one variable cancelled on both sides. Set T&sub1; = T&sub2; and the temperatures vanish from the fraction, leaving Boyle. Set P&sub1; = P&sub2; and you are left with Charles. Nothing new is needed for the general case except the patience to keep six numbers straight.

### Worked example at the defaults

The defaults describe a gas at 100 kPa, 2 L and 300 K compressed to 200 kPa at the same 300 K. Left side: 100 × 2 ÷ 300 = **0.667 kPa&middot;L/K**. Right side with V&sub2; = 1 L gives 200 × 1 ÷ 300 = 0.667, and the two agree.

Because the temperature did not change, only the pressure and volume moved, and they moved inversely: double the pressure, halve the volume. If T&sub2; had been raised to 450 K instead, the final volume would be 100 × 2 × 450 ÷ (300 × 200) = **1.5 L**, because the hotter gas needs more room at the same pressure.

The calculator also runs backwards. Feed it the two volumes and the starting temperature and pressure, leave the final pressure blank, and it returns P&sub2; = 100 × 2 × 300 ÷ (300 × 1) = 200 kPa. Same six numbers, different unknown, identical invariant.

### Every path to the same constant

| Change from 100 kPa, 2 L, 300 K | P₂ (kPa) | V₂ (L) | T₂ (K) | P₂V₂/T₂ |
| --- | --- | --- | --- | --- |
| Halve the volume, hold T | 200 | 1 | 300 | 0.667 |
| Heat at constant volume | 150 | 2 | 450 | 0.667 |
| Expand at constant T | 50 | 4 | 300 | 0.667 |
| Cool at constant volume | 75 | 2 | 225 | 0.667 |
| Compress and heat together | 300 | 1 | 450 | 0.667 |

Five different routes, five different final states, one unchanging 0.667 kPa&middot;L/K. That is the practical value of the law: you do not need to know which sequence of compressions and heatings the gas actually went through. Only the endpoints matter, because the invariant depends on the state and not the path.

### A balloon that changes everything at once

A weather balloon released from sea level starts at 100 kPa, 2 L and 300 K. At 12 km the pressure has fallen to about 20 kPa and the gas has cooled to 260 K. Solve for the volume: V&sub2; = 100 × 2 × 260 ÷ (300 × 20) = **8.67 L**, over four times the launch volume.

Both drivers push the same way here. The pressure drop alone would take 2 L to 10 L, and the temperature drop pulls that back to 8.67 L. Reverse the temperature change, warming to 320 K instead, and the same pressure drop would give 10.7 L. That is how delicate high-altitude balloon design is: a 60 K swing moves the answer by 23%.

### What actually moves the answer

- Pressure ratio: volume falls in direct proportion, so 100 to 400 kPa at fixed temperature is a fourfold compression.
- Temperature ratio in kelvin: volume rises in direct proportion, and 20 &deg;C to 60 &deg;C is only a 14% rise because 293 K to 333 K is the real ratio.
- Amount of gas: outside the scope of this law, and the fastest way to get a wrong answer, since a leak looks exactly like a pressure drop.
- Phase change: condense part of the vapour and the effective molecule count falls, so the volume collapses faster than any of the three laws predict.
- Measurement error in the small state: at 0.5 L a 10 mL misread is 2%, which propagates straight into the final volume.

### When you need PV = nRT instead

The combined law holds the amount of gas fixed. The moment a reaction produces or consumes molecules, a cylinder leaks, or you need to go from a mass of gas to a volume, the ideal gas law takes over. PV = nRT uses R = 8.314 J/(mol&middot;K), and with 0.0821 L&middot;atm/(mol&middot;K) if you prefer atmospheres and litres.

Check the defaults against it. At 100 kPa and 2 L and 300 K, n = PV/RT = 200 ÷ (8.314 × 300) = 0.0802 mol, about 2.3 g of air. That mole count then stays fixed in the combined law, which is exactly the assumption it makes silently.

#### Real gas corrections near condensation

Both laws treat molecules as points that never attract each other. Near the boiling point those assumptions fail, and the volume can be 5–20% off the ideal prediction. Water vapour at 100 &deg;C is close to ideal; water vapour at 60 &deg;C is not, because it is only 20 K above its condensation point and clustering heavily.

#### A quick sanity check before you trust the answer

Compare the two ratios rather than the absolute states. If pressure doubled and temperature is unchanged, volume must have halved, no matter what the numbers are. If the answer implies volume grew while pressure rose and temperature fell, one of the six inputs is in the wrong unit — almost always a Celsius value typed into a kelvin field.

## FAQ

### What is the combined gas law?

P&sub1;V&sub1;/T&sub1; = P&sub2;V&sub2;/T&sub2; for a fixed amount of gas. At the defaults, 100 kPa and 2 L at 300 K gives 0.667 kPa&middot;L/K, and compressing to 200 kPa at the same temperature leaves 1 L.

### How do I convert Celsius to kelvin?

Add 273.15. So 25 &deg;C is 298.15 K and 100 &deg;C is 373.15 K. Entering 25 instead of 298.15 shrinks the denominator by a factor of twelve.

### How is this different from the ideal gas law?

The combined law fixes the amount of gas and compares two states. The ideal gas law adds moles, PV = nRT, so it can handle a leak, a reaction or a mass-to-volume conversion.

### What happens if pressure doubles and temperature doubles?

Volume stays the same. Doubling P and T cancels in P×V/T, so 2 L at 100 kPa and 300 K becomes 2 L at 200 kPa and 600 K.

### Can I use mmHg and mL instead of kPa and litres?

Yes. Any consistent pressure unit and any consistent volume unit work, because the units cancel on both sides. Just do not use kPa on one side and atm on the other.

### Why does my answer disagree with the textbook?

Usually temperature. Textbooks often use 273 K or 298 K where you used 300 K, a 0.7–9% difference that shows up in the third digit of the volume.

### How do I solve for the final temperature?

T&sub2; = P&sub2;V&sub2;T&sub1; ÷ (P&sub1;V&sub1;). From 100 kPa, 2 L, 300 K to 200 kPa at 1 L you get 300 K, unchanged, because both ratios moved together.

### Does a balloon expand or contract as it rises?

It expands, because the pressure drop dominates. Going from 100 kPa to 20 kPa while cooling from 300 K to 260 K takes 2 L to 8.67 L.

### What if some of the gas condenses?

The law no longer applies, because the molecule count in the gas phase changes. Condensation removes molecules and the volume collapses faster than P×V/T predicts, often by 10% or more near the dew point.

## Method and sources

Methodology: Physical constants follow CODATA 2022 recommended values, and formulas follow standard physics definitions.

Last updated: 2026-11-17.
- Combined gas law (P₁V₁/T₁ = P₂V₂/T₂) for a fixed amount of gas.