# Beam Span Calculator

Estimate the required section modulus and a starting beam depth from span, load and allowable stress.

## Quick answer

**Quick answer:** with the default inputs (12 ft, 40 lb/sq ft, 6 ft, 1,200 psi), the required section modulus is **43.2**. At these inputs: uniform load = **240**, maximum moment = **4,320**. Change any input to update the result.

## Default calculation

Values computed by this calculator at exactly the default inputs listed below.

### Inputs (defaults)

| Input | Value | Unit |
| --- | --- | --- |
| Beam span | 12 | ft |
| Design load | 40 | lb/sq ft |
| Tributary width | 6 | ft |
| Allowable stress | 1200 | psi |

### Outputs at these defaults

| Output | Value | Unit |
| --- | --- | --- |
| Required section modulus | 43.2 |  |
| Uniform load | 240 |  |
| Maximum moment | 4320 |  |
| Suggested depth | 7.2 |  |

## Formula

```text
S = M ÷ &sigma;, M = w × L² ÷ 8
```

## Inputs

| Variable | Type | Unit | Default |
| --- | --- | --- | --- |
| Beam span | number | ft | 12 |
| Design load | number | lb/sq ft | 40 |
| Tributary width | number | ft | 6 |
| Allowable stress | number | psi | 1200 |

## Outputs

| Result | Format |
| --- | --- |
| Required section modulus | primary |
| Uniform load | number |
| Maximum moment | number |
| Required section modulus | number |
| Suggested depth | number |

## How it works

### What the number means

A beam carrying a floor or roof load bends, and the bending peaks at mid-span of a simply supported run. The output this calculator gives you — the **required section modulus**, in cubic inches — is the geometric property a beam&rsquo;s cross-section must have so the bending stress stays inside the allowable limit of the material. At the defaults (a 12 foot span carrying 40 lb/sq ft over a 6 foot tributary width at 1,200 psi allowable stress), the beam needs **43.2 in³** of section modulus and a starting depth of about 7.2 inches.

### How the formula works

#### From line load to moment to size

Work it from the inside out. First, the floor load times the tributary width converts a distributed floor load into a line load the beam actually carries: 40 × 6 = **240 lb per foot**. The tributary width is half the joist span on each side of the beam — if joists run 12 feet to the next beam, the beam catches 6 feet of that load. Second, the maximum moment formula wL²/8 captures the fact that bending grows with the **square** of the span: doubling the span quadruples the moment. Third, dividing the moment in pound-feet by 12 and by the allowable stress in psi gives the required section modulus in cubic inches.

### Worked example at the defaults

Run the defaults step by step. Uniform load: 40 lb/sq ft × 6 ft = 240 lb/ft. Maximum moment: 240 × 12² ÷ 8 = 240 × 144 ÷ 8 = **4,320 lb-ft**. Required section modulus: 4,320 × 12 ÷ 1,200 = **43.2 in³**. The suggested depth is span times 12 divided by 20, an L/20 rule of thumb: 12 × 12 ÷ 20 = **7.2 inches**. A nominal 2×10 (9.25 inches actual) with a section modulus near 64 in³ clears that requirement with margin, while a 2×8 at roughly 31 in³ falls short in bending — and that is exactly the comparison the calculator is built for.

### Section modulus by span

| Span | Max moment (lb-ft) | Required S (in³) | Suggested depth |
| --- | --- | --- | --- |
| 8 ft | 1,920 | 19.2 | 4.8 in |
| 10 ft | 3,000 | 30.0 | 6.0 in |
| 12 ft | 4,320 | 43.2 | 7.2 in |
| 16 ft | 7,680 | 76.8 | 9.6 in |
| 20 ft | 12,000 | 120.0 | 12.0 in |

The table assumes the same 40 lb/sq ft load, 6 foot tributary width and 1,200 psi allowable stress as the defaults. Read the span column carefully: moving from 12 feet to 16 feet nearly doubles the required section modulus from 43.2 to 76.8 in³, because moment scales with the square of span. This is why long clear spans push you from sawn lumber to engineered members.

### What moves the required size

- Span — the dominant factor, since moment grows with L²
- Tributary width — tighter joist spacing concentrates more load on the beam
- Design load — living space is 40 lb/sq ft; sleeping rooms 30; storage decks and snow areas 50+
- Allowable stress — species and grade matter; 1,200 psi suits common Douglas fir-larch framing grades
- Deflection — stiffness, not strength, often forces a deeper beam before stress does

#### Strength versus stiffness

The formula above checks strength only. Beams also deflect, and codes limit deflection to about L/360 for live load on floors. A beam can pass the strength check yet feel bouncy underfoot because its depth is too small. The suggested depth of span ÷ 20 exists precisely for this: hitting that depth ratio usually satisfies deflection at typical residential loads, and when deflection governs you size up in depth rather than in width.

### Material choices at 43.2 in&sup3;

At the default requirement, several real options work. A tripled 2×10 of No. 2 Douglas fir-larch carries about 64 in³ of section modulus and passes comfortably. Engineered lumber is efficient at this size: a 9.5 inch LVL or a parallam beam clears the requirement with less total depth than built-up sawn lumber. Steel changes the math entirely — an 8 inch steel beam&rsquo;s section modulus is several times larger than a wood 2×10&rsquo;s, which is why steel appears where spans exceed 20 feet or headroom is tight. The calculator&rsquo;s number is material-agnostic: any member whose section modulus clears the requirement, and whose depth satisfies deflection, is a candidate.

### Permits, bearing and connections

Removing a load-bearing wall almost always requires a permit and, in most US jurisdictions, a stamped drawing from an engineer for anything beyond a short header. Two checks the calculator leaves out matter as much as bending: **bearing**, where the beam ends need enough contact area that the wood is not crushed — typically a few inches of bearing on posts or studs — and **connections**, where posts, footing sizes and joist hangers must each carry their share. Footings under posts often end up bigger than the beam choice itself.

### When to call an engineer

Use this calculator as a sizing filter, not a final answer. Bring in a structural engineer when the span exceeds 16 feet, when the beam supports more than one floor, when loads are unusual — a hot tub, a safe, a masonry chimney — or when the layout involves cantilevers, stair openings or non-standard framing. An engineer typically charges $300–$1,000 for a single-beam analysis and letter, which is cheap insurance against a floor that sags or a header that cracks drywall within a year. Have the final member stamped and permit-ready before the wall comes down.

## FAQ

### What is section modulus on a beam?

It is a geometric property of the cross-section that measures resistance to bending, in cubic inches. Required section modulus equals the maximum bending moment divided by the allowable stress — at the defaults, 4,320 lb-ft ÷ 1,200 psi gives 43.2 in³.

### How far can a beam span without support?

It depends on load and member size. At a 40 lb/sq ft floor load over a 6 ft tributary width, a tripled 2×10 comfortably carries 12 feet, while 20 foot spans need engineered lumber or steel — the required section modulus jumps to 120 in³ at 20 feet.

### What does tributary width mean for a beam?

It is the floor width the beam catches, roughly half the joist span on each side. Joists spanning 12 feet onto the beam give a tributary width of 6 feet, which the calculator multiplies by the design load to get the line load.

### How deep should a beam be?

A practical rule is depth at least span ÷ 20 in inches: a 12 foot beam wants about 7.2 inches of depth, a 20 foot beam about 12 inches. Deflection, not strength, is usually what forces the depth up.

### What allowable bending stress should I use?

The 1,200 psi default suits common No. 2 Douglas fir-larch framing. Species, grade and wet-service conditions shift it from roughly 600 to 2,000 psi — use the grade stamp value, not a guess.

### Why does the moment grow with the square of the span?

Bending moment equals wL²/8 for a uniform load: doubling the span from 12 to 24 feet quadruples the moment from 4,320 to 17,280 lb-ft, which is why long spans require disproportionately bigger beams.

### Does this calculator check deflection?

No, it checks bending strength only. The suggested depth of span ÷ 20 is a deflection rule of thumb. When deflection governs, size up in depth rather than width.

### Do I need an engineer to remove a load-bearing wall?

In most jurisdictions yes, for anything beyond a short header — expect $300–$1,000 for a single-beam stamped drawing. The calculator is a sizing filter to discuss intelligently, not a permit document.

## Method and sources

Methodology: Cost ranges reflect 2026 U.S. national averages for materials and labor; regional pricing varies, so use results as a planning baseline and confirm with local quotes.

Last updated: 2026-11-17.
- Simply supported beam maximum moment wL²/8; section modulus S = M / allowable stress.