CalcSeed

Volumetric Flow Rate Converter

Convert volumetric flow rate between cubic metres per second, litres per second, GPM, cubic metres per hour and cubic feet per second.

=
Volumetric flow rate converter — 1 m³/s = 1,000 L/s, and 1 GPM = 0.06309 L/s.
1 m³/s = 1,000 L/s  ·  1 GPM = 0.06309 L/s
Result
—

What this converter does

Flow rate is volume per unit time, and every trade picks its own pair: pump curves in m³/h, plumbing in L/min, US wells and irrigation in gallons per minute, rivers and hydrology in ft³/s. This tool converts between those five plus L/s, pivoting on the cubic metre per second. At the defaults, 100 m³/h returns 440.29 GPM.

The factors and the two easy anchors

1 m³/s = 1,000 L/s = 3,600 m³/h = 35.3147 ft³/s  ·  1 GPM = 0.0630902 L/s = 0.227125 m³/h

Everything follows from three definitions. A cubic metre is 1,000 litres, an hour is 3,600 seconds, and a cubic foot is 0.028316846592 m³. So 1 m³/h is 1,000 ÷ 3,600 = 0.277778 L/s, and 1 m³/s is 3,600 m³/h. Those two anchors cover most pump and pipe work without touching a calculator.

The US gallon is the awkward one: 3.785411784 litres exactly, which makes 1 GPM = 3.785411784 ÷ 60 = 0.0630902 L/s. In the other direction, 1 L/s is 15.8503 GPM and 1 m³/h is 4.40287 GPM. The 4.4 figure is worth remembering because metric pump curves and US irrigation specs meet on exactly that ratio.

Worked example: 100 m³/h

One hundred cubic metres per hour is 100 ÷ 3,600 = 0.027778 m³/s. In GPM: 0.027778 ÷ 0.0000630902 = 440.29 GPM, the default answer. The same flow is 27.778 L/s, 1,666.67 L/min and 0.981 ft³/s. Five numbers, one pump, and only the GPM figure would look out of place on a European datasheet.

Sanity-check it against a real system. A 4-inch pipe at 2 m/s carries about 0.016 m³/s, or 58 m³/h, so a 100 m³/h line needs a 5-inch pipe at the same velocity. That is why flow rate and pipe diameter have to be read together: doubling the diameter quadruples the capacity at a given velocity.

Flow rates at a glance

SourceL/sGPM
Low-flow shower head0.152.4
Garden hose, full flow0.3–0.64.8–9.5
Residential well pump0.63–1.2610–20
4-inch pipe at 2 m/s16.2257
Typical fire hydrant631,000

Every GPM cell is the L/s figure times 15.8503, so the rows agree with the factors above. The hydrant row explains why fire flow tests quote four-digit numbers while a house runs on a 20 GPM well: a 1,000 GPM hydrant is 63 L/s, roughly 50 times a domestic supply.

Where the conversion causes problems

Pumps and pipe sizing

A pump curve printed in m³/h and a control valve rated in GPM is the classic mismatch. A 100 m³/h pump is 440 GPM, so a valve sized for 300 GPM runs wide open and passes only 68% of design flow. Size the valve on the converted figure, never on the number printed on the pump nameplate.

Velocity is the other half of the check. Capacity in a pipe is area times velocity, and a 2-inch line at 1.5 m/s moves 3.04 L/s, or 48.2 GPM. If a specification asks for 100 GPM through 2-inch pipe, velocity climbs to 3.1 m/s, above the usual 1.5–2.5 m/s design band, and the line will be noisy and erosion-prone.

Hydrology and irrigation

US hydrology quotes rivers in ft³/s, often called cusecs, while water rights and treatment plants quote MGD, millions of US gallons per day. One ft³/s is 448.831 GPM, which is 0.6463 MGD, so a 100 ft³/s river is 64.6 MGD or 2.832 m³/s. Irrigation pivots are rated in GPM per acre, and an acre-inch per hour is 452.6 GPM, a figure that never appears on a metric datasheet.

Plant capacity adds a third time base. A 1,000 m³/day works out to 11.57 L/s or 183.5 GPM, because a day is 86,400 seconds. Quotes that mix per-day and per-hour figures are the usual source of an undersized treatment unit: 1,000 m³/day is 41.67 m³/h, and a pump selected for 1,000 m³/h is 24 times too large.

Affinity laws explain why the unit error gets expensive. Flow scales with pump speed, head with the square of speed and power with the cube, so doubling a duty from 50 to 100 m³/h multiplies absorbed power by eight. A 4 kW pump becomes a 32 kW pump on the same impeller, which is why a flow figure read in the wrong unit is not a rounding problem.

Precision and rounding

  • Round GPM to a whole number; a pump curve is accurate to a few percent, so 440 GPM and 440.3 GPM are the same machine.
  • Keep four significant figures for L/s when converting to GPM, because 0.0630902 truncated to 0.063 is already 0.14% low.
  • Convert from the original reading in one step; m³/h to GPM to L/s compounds two roundings for no benefit.
  • A pump curve is read at the duty point, where the system curve crosses it, so a flow figure without head is half a specification.
  • Pipe capacity scales with the square of diameter, so a 4-inch line carries four times a 2-inch line at the same velocity.
  • Design velocity is 1.5–2.5 m/s for most building services; above 3 m/s noise and erosion become the constraint.

Mistakes that mis-size a system

The first is using imperial gallons. A US gallon is 3.785 L and an imperial gallon is 4.546 L, 20% larger, so a UK pump rated 100 GPM delivers 454.6 L/min against 378.5 from a US-rated unit with the same label. The second is confusing flow with volume: a 100 m³/h pump moves 2,400 m³ a day, but only if it runs 24 hours at rated flow, and most domestic pumps cycle at about 50% duty.

The third is dividing by 60 in the wrong place. m³/h to L/min is ×16.667, not ×1,000 or ÷60, because both the volume and the time unit change. The fourth is treating ft³/s and m³/s as roughly equal. One m³/s is 35.31 ft³/s, so a 1,000 ft³/s flood is 28.3 m³/s, and the error on that one is a factor of 35.

Frequently asked questions

How do I convert m³/h to L/s?

Multiply by 0.277778. So 10 m³/h is 2.78 L/s, 100 m³/h is 27.78 L/s, and 360 m³/h is exactly 100 L/s.

How do I convert GPM to L/s?

Multiply by 0.0630902. So 10 GPM is 0.63 L/s, 100 GPM is 6.31 L/s, and 1,000 GPM is 63.09 L/s.

How many L/s are in a cubic metre per second?

Exactly 1,000 L/s, which is also 3,600 m³/h and 35.3147 ft³/s.

How many GPM is 100 m³/h?

440.29 GPM, the calculator default. That is 27.78 L/s, 1,666.67 L/min or 0.981 ft³/s.

How many GPM in a ft³/s?

448.831 GPM, since 1 ft³/s is 0.0283168 m³/s and 1 GPM is 0.00006309 m³/s.

Is a US gallon per minute the same as an imperial one?

No. A US gallon is 3.785 L and an imperial gallon 4.546 L, so 100 imperial GPM is 454.6 L/min against 378.5 for 100 US GPM.

How do I convert m³/h to GPM?

Multiply by 4.40287. So 10 m³/h is 44.03 GPM, 25 m³/h is 110.07 GPM, and 100 m³/h is 440.29 GPM.

How much flow does a 2-inch pipe carry?

About 3.04 L/s or 48.2 GPM at 1.5 m/s. Push 100 GPM through it and velocity rises to 3.1 m/s, above normal design limits.

What is 1 L/s in litres per minute?

60 L/min, exactly. The L/min factor is 0.0000166667 m³/s, which is 1 litre every sixtieth of a second.

Method and sources

Calculation basis

Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: November 19, 2026
Formula & data sources
  • SI derived unit: cubic metre per second.
  • US gallon: 3.785411784 L.

Cite this page

Reference formats
APA 7CalcSeed. (2026, November 19). Volumetric Flow Rate Converter. https://calcseed.com/c/unit/volumetric-flow-rate-converter/
MLA 9"Volumetric Flow Rate Converter." CalcSeed, 19 Nov. 2026, calcseed.com/c/unit/volumetric-flow-rate-converter/.
ChicagoCalcSeed. "Volumetric Flow Rate Converter." Last modified November 19, 2026. https://calcseed.com/c/unit/volumetric-flow-rate-converter/

Related calculators