CalcSeed

Natural Gas Energy Converter

Convert natural gas energy between MMBTU, therms, kWh, megajoules and gas volumes in m³ or ft³.

=
Natural gas energy converter — 1 MMBTU = 10 therms, and 1 therm ≈ 29.31 kWh.
1 MMBTU = 10 therms  ·  1 therm ≈ 29.307 kWh
Result
—

What this converter does

Natural gas reaches your meter as a volume but is sold as energy. Enter a figure, choose the unit on each side, and this tool converts across six measures: MMBTU, therms, kilowatt-hours, megajoules, cubic metres of gas and cubic feet of gas. Every unit is stored as a fraction of one MMBTU, so each conversion is a single division. At the defaults, 1 therm comes back as 29.31 kWh.

The conversion factors

1 MMBTU = 10 therm = 293.071 kWh = 1,055.06 MJ = 27.307 m³ = 964.32 ft³

The MMBTU is one million British thermal units, and it is the pivot. A therm is exactly 100,000 BTU, so ten therms make an MMBTU with no rounding: 0.1 MMBTU per therm. A kilowatt-hour is 3,600,000 J, or 3,412.14 BTU, which gives 0.003412141633 MMBTU. A megajoule is 0.000947817120 MMBTU, since 1 BTU is 1,055.06 J.

The two volume units need a heating value before they can be treated as energy. This tool uses 1,037 BTU per cubic foot, the long-run US average for pipeline gas, giving 0.001037 MMBTU per ft³. A cubic metre holds 35.3147 ft³, so 1 m³ carries 0.036621 MMBTU, or 36,621 BTU. Those two factors are the only approximate ones here, and they are exactly where a real bill drifts from a calculated one.

Worked example: one therm in kWh

One therm is 0.1 MMBTU. Divide by the kWh factor: 0.1 ÷ 0.003412141633 = 29.307 kWh, which the result panel shows as 29.31. Run it backwards and 1 kWh = 0.003412141633 ÷ 0.1 = 0.0341 therm, so a 1,500 kWh month of resistance heating carries the energy of about 51.2 therms.

A 500 ft³ reading is 500 × 0.001037 = 0.5185 MMBTU = 5.185 therms, and 5.185 × 29.307 = 151.96 kWh. A 100 m³ metric bill is 100 × 0.036621 = 3.6621 MMBTU = 36.62 therms = 1,073.2 kWh. Both answers come from one multiplication against the pivot, which is why they agree with each other to the last digit.

Natural gas conversions at a glance

FromToMultiply by
MMBTUtherm10
thermkWh29.3071
thermMJ105.506
MMBTUm³ of gas27.307
m³ of gaskWh10.732
ft³ of gastherm0.01037

Read the last row backwards and you get the rule installers use: about 96.4 ft³ of gas makes one therm. That is why a therm and a CCF (100 ft³) get treated as near-synonyms on US bills, even though a CCF is really 1.037 therms.

Where the conversion bites in practice

Reading a US gas bill

US utilities bill in therms or in CCF, and the two differ by 3.7%. A 70-therm winter month at $1.15–$1.70 per therm runs $80–$119 before the fixed customer charge. If your bill quotes dollars per CCF instead, divide that rate by 1.037 before comparing it with a dollars-per-therm offer, or a rate that looks cheaper can be the dearer gas.

Annual volumes are easier to sanity-check in MMBTU. A typical US home burns roughly 630 therms, or 63 MMBTU, a year, which is about 64,000 ft³ at the 1,037 BTU factor. A 100,000 BTU/hr furnace running flat out for 100 hours moves 10 MMBTU, one-sixth of that annual figure in under five days.

Why the volume factors are approximate

The energy in a cubic foot depends on what the gas is made of. Pipeline-quality gas in the US runs from about 1,000 to 1,100 BTU per ft³, and utilities publish a monthly heat content that moves with supply. The 1,037 BTU factor sits mid-range, so converting a large volume can land 3–6% away from the utility’s own number.

Definitions differ too. The therm is 100,000 BTU on a higher heating value (HHV) basis, which counts the latent heat in the water vapour a boiler vents. European suppliers quote MJ on an HHV basis as well, but some industrial contracts use LHV, roughly 90% of HHV for natural gas. Confirm the basis before converting a large supply deal.

Metric bills quoted in kWh

European and Australian bills quote kWh directly. One cubic metre is 10.732 kWh at the factor here, inside the 10.5–11.1 kWh/m³ band quoted across European networks. To move a metric bill into US terms, multiply kWh by 0.034121 to get therms: 1,000 kWh is 34.12 therms, or 3.412 MMBTU.

Precision and rounding

The energy factors are exact definitions; the volume factors are averages. The result panel rounds to two decimals, which suits a single reading but not an annual total.

  • Round a bill comparison to 0.1 therm; two decimals imply a precision the meter does not have.
  • Carry full precision through a chain and round only the last figure, or three steps can drift 1–2%.
  • Never add HHV therms to LHV megajoules in one total without converting one of them first.
  • A residential meter reads in ft³ or m³, while the bill charges therms, so the meter number is not the billed number.
  • A metric meter and an imperial one differ by 35.3147, so a 100-unit metric reading is 3,531 ft³, not 100 ft³.
  • Sub-metering a tenant usually means splitting therms by floor area, because one meter cannot separate two occupancies.

Mistakes that cost money

The expensive one is reading MBTU as MMBTU. In gas trading MBTU means one thousand BTU and MMBTU means one million, so a contract at $3 per MBTU is a thousand times the unit price of $3 per MMBTU. Only the second M separates them, and a slip of the pen moves a supply bill by three orders of magnitude.

The second is treating a decatherm as a therm. One Dth is 10 therms, exactly one MMBTU, and industrial tariffs quote dollars per Dth while homes see dollars per therm, so $10/Dth and $1.00/therm are the same fuel at the same price. The third is assuming a cubic metre and a cubic yard are close: a m³ is 1.308 yd³, a 31% difference that ruins any volume-based estimate.

Frequently asked questions

How many therms are in an MMBTU?

Exactly 10, because 1 MMBTU is 1,000,000 BTU and 1 therm is 100,000 BTU. Inverted, 1 therm is 0.1 MMBTU.

How do I convert therms to kWh?

Multiply by 29.3071. One therm is 29.31 kWh, 50 therms is 1,465.4 kWh, and 1,000 therms is 29,307 kWh.

How many cubic feet of gas make one therm?

About 96.4 ft³ at 1,037 BTU per ft³. A CCF, which is 100 ft³, is therefore 1.037 therms, 3.7% more energy than a therm.

Is a CCF the same as a therm?

Nearly. A CCF is 100 cubic feet and equals 1.037 therms, so a 70-therm month is 67.5 CCF. Use 1.037 as the divisor when swapping between the two rates.

How many kWh is a cubic metre of natural gas?

10.732 kWh at the 1,037 BTU factor used here. European bills typically quote 10.5–11.1 kWh/m³ depending on the gas quality.

What is the difference between MBTU and MMBTU?

MBTU is one thousand BTU, MMBTU is one million. A price of $3/MBTU equals $3,000/MMBTU, so the two are never interchangeable in a contract.

What does a therm of natural gas cost in 2026?

US residential rates run about $1.15–$1.70 per therm, so a 70-therm winter month is $80–$119 before fixed charges. Wholesale hub prices sit far lower, near $2–$4 per MMBTU.

How many MMBTU does a house use in a year?

A typical US home uses roughly 63 MMBTU, or 630 therms, which is about 64,000 ft³ of gas at 1,037 BTU per ft³.

Why is one therm not a round number of kWh?

Because the two units were defined separately. A therm is 100,000 BTU and a kWh is 3,412.14 BTU, so 100,000 ÷ 3,412.14 = 29.307 kWh, a ratio with no exact decimal form.

Method and sources

Calculation basis

Conversion factors follow the NIST International System of Units (SI); factors that are exact by definition are marked exact.

Last updated: November 19, 2026
Formula & data sources
  • Therm definition: 100,000 BTU.
  • Typical natural gas heating value of about 1,037 BTU per cubic foot.

Cite this page

Reference formats
APA 7CalcSeed. (2026, November 19). Natural Gas Energy Converter. https://calcseed.com/c/unit/natural-gas-energy-converter/
MLA 9"Natural Gas Energy Converter." CalcSeed, 19 Nov. 2026, calcseed.com/c/unit/natural-gas-energy-converter/.
ChicagoCalcSeed. "Natural Gas Energy Converter." Last modified November 19, 2026. https://calcseed.com/c/unit/natural-gas-energy-converter/

Related calculators